  • All Stainless Steel Construction
  • Meets 3A Sanitary Standards
  • NEMA 4X Enclosure
  • Dairy, Food Processing, Pharmaceutical, Biotech Applications
  • High Reliability
  • 1½ or 2" Tri-GripTM (Tri-Clamp® Compatible)
  • NIST

Descripción

The PX791 and PX792 Series has been discontinued. Please see the PX409S Sanitary Series as possible alternatives or contact our Pressure Engineering department.

PX792 Series transducers use proven thin-film technology and precision machining and electro-polishing to meet 3-A standards.

SPECIFICATIONS
Excitation: 10 to 36 Vdc unregulated reverse voltage protected
Output: 4 to 20 mA 2-wire, 1 to 5 Vdc unregulated
Zero Balance: ±1% FS Vmin = 10V + (0.022A) x RL
Linearity: ±0.4% BFSL
Hysteresis: +0.2%
Repeatability: ±0.07%
Stability: ±1% FS/year
Durability: 100M cycles
Operating Temperature: -29 to 82°C (-20 to 180°F)
Compensated Temperature: -1 to 54°C (30 to 130°F)
Thermal Effects:
Zero: ±0.04% FS/°F
Span: ±0.04% FS/°F
Proof Pressure: 200% range
Burst Pressure: 800% range
Gage Type: Stainless steel diaphragm, diffused silicon sensor
Vibration: <±0.1% FS effect for 20 g, 0 to 2000 Hz in any axis
Shock: Less than ±0.05% FS effect for 100 g, 20 ms shock in any axis
Position Effect: <0.1% FS
Response Time: 5 ms
Wetted Parts: 316L stainless steel electro-polished
Fill Fluid: USP grade 99.5% glycerin
Pressure Port: 1½ or 2" Tri-Grip style
Case: 300 Series SS
Electrical Connection: 24 AWG, 91.4 cm (36") PVC, shielded, vented, UL approved
Weight: 383 g (13.5 oz)
Hacer Pedido(Especifique el Número de Modelo)
Número de parte/Desc.
Cant.
Descripción
PX792-V30GI
Consultar Ventas  
Disponible en: 
 
 
Sanitary transmitter with 2' Tri-Clamp fitting, vacuum to 30 psig range and 4 to 20 mA output
PX792-V60GI
Consultar Ventas  
Disponible en: 
 
 
Sanitary transmitter with 2' Tri-Clamp fitting, vacuum to 60 psig range and 4 to 20 mA output
PX792-V100GI
Consultar Ventas  
Disponible en: 
 
 
Sanitary transmitter with 2' Tri-Clamp fitting, vacuum to 100 psig range and 4 to 20 mA output
PX792-30GI
Consultar Ventas  
Disponible en: 
 
 
Sanitary transmitter with 2' Tri-Clamp fitting, 0-30 psig range and 4 to 20 mA output
PX792-60GI
Consultar Ventas  
Disponible en: 
 
 
Sanitary transmitter with 2' Tri-Clamp fitting, 0-60 psig range and 4 to 20 mA output
PX792-100GI
Consultar Ventas  
Disponible en: 
 
 
Sanitary transmitter with 2' Tri-Clamp fitting, 0-100 psig range and 4 to 20 mA output
PX792-200GI
Consultar Ventas  
Disponible en: 
 
 
Sanitary transmitter with 2' Tri-Clamp fitting, 0-200 psig range and 4 to 20 mA output
PX792-300GI
Consultar Ventas  
Disponible en: 
 
 
Sanitary transmitter with 2' Tri-Clamp fitting, 0-300 psig range and 4 to 20 mA output
PX792-500GI
Consultar Ventas  
Disponible en: 
 
 
Sanitary transmitter with 2' Tri-Clamp fitting, 0-500 psig ange and 4 to 20 mA output
PX792-750GI
Consultar Ventas  
Disponible en: 
 
 
Sanitary transmitter with 2' Tri-Clamp fitting, 0-750 psig range and 4 to 20 mA output
PX792-1KGI
Consultar Ventas  
Disponible en: 
 
 
Sanitary transmitter with 2' Tri-Clamp fitting, 0-1,000 psig range and 4 to 20 mA output
Todas las cantidades que se muestran en MXN
Nota: To order with 1½" Tri-Clamp fitting, change model number to PX791, no additional charge.

Generador de Número de Parte

Construya su Número de Parte Abajo
Opciónes de Descripción:


(1) Fitting seleccionar de:
1 para 1 1/2 inch sanitary fitting
2 para 2 inch sanitary fitting

(2) Range seleccionar de:
V30 para Vacuum to 30 psig
V60 para Vacuum to 60 psig
V100 para Vacuum to 100 psig
30 para 0-30 psig
60 para 0-60 psig
100 para 0-100 psig
200 para 0-200 psig
300 para 0-300 psig
500 para 0-500 psig
750 para 0-750 psig
1K para 0-1000 psig

(3) Output seleccionar de:
I para 4-20 mA output
5V para 1-5 Vdc output
Nota: Todas las combinaciones pueden no ser válidas, revise la hoja de especificaciones para números de parte válidos