  • Accurate to ±0.2°C (±0.4°F) with 0.1 or 0.01° Resolution
  • Direct Temperature Input/Output
  • Eight Standard T/C Types Available: J, K, E, T, R, S, B, N, and mV
  • Eight RTD Curves Available in Platinum, Copper, and Nickel
  • Auto Detection of 2-, 3-, or 4-Wire Connection Indicator
  • Guaranteed to Work with All Pulsed Instruments
  • Compatible with Devices Using Pulsed Excitation Currents, Including PLCs, DCS, and Recorders
  • EZ-Dial™ Knob Easily Adjusts Output by 0.1°
  • EZ-Check™ Switch for 0 and 100% Span Adjustments
  • Store New EZ-Check™ Values by Pressing the EZ-Dial Knob
  • Selectable Auto-Stepping
  • Superior Battery Life of 45 Hours under Typical Continuous Usage
  • NIST-Traceable Calibration Certificate Included

Descripción

The CL543 model has been discontinued. Please see the CL543B RTD and thermocouple calibrator as a possible alternative or contact our Temperature Engineering department.

The OMEGA™ CL543 dual T/C and RTD calibrator provides direct temperature calibration to all types of instruments such as transmitters, recorders, controllers, alarms, and data acquisition and computer systems. The CL543 also reads RTD and T/C outputs and displays temperature. It is compatible with pulsed systems and transmitters and has a feature for troubleshooting. The auto detection of 2-, 3-, or 4-wire connections will tell you if you have the wires correctly connected. You can also select “auto stepping,” which offers selectable step sizes and time in-between steps. This calibrator is a superior replacement for decade boxes, eliminating the lugging around of large equipment and the possibility of misreading RTD tables. The CL543 offers the highest performance and the most features in its class by exceeding the accuracy and functions of many higher priced T/C and RTD calibrators. It is a low-cost solution for checkout and calibration of all T/C and RTD instruments in the field, shop, or control room.
Hacer Pedido(Especifique el Número de Modelo)

Lo que han comprado otras personas: Cuando vea este icono, haga clic sobre él para abrir la lista de productos que otras personas han comprado al adquirir este modelo

Número de parte/Desc.
Cant.
Descripción
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloSC-800
SC-800
Consultar Ventas  
Disponible en: 
 
 
Soft carrying case
Todas las cantidades que se muestran en MXN
Nota: The CL543 come with NIST certification, operator’s manual and 9 V battery.
We noticed you are from the US. Visit your local site for regional offers and live support.