Carrito de Compra  |  Contacto  |  Ayuda  |  Correo electrónico  | 
En México: 01800-953-00-93
Fuera de México:+52 (81) 8335-3774

Temperature Controllers

CN350, CN360, & CN370 Series

Easy to Use Temperature Controllers | CN350, CN360, & CN370 Series

Easy to Use Temperature Controllers

Ver Todas los Modelos Abajo

1 año de garantía
  • Economical, Easy to Use
  • 1 /16 DIN Panel Cutout
  • Input Types; J, K, R, S Thermocouples and 100 .Platinum RTD
  • Fixed Proportional Band (4%) with Manual Reset
  • Fixed Cycle Time: 30 s for Mechanical Relay and 3 s for dc Solid State Output
  • User Convertible for Proportional or On-Off Control
Controladores de temperatura y proceso y dispositivos de conmutación de potencia - Ver Productos Relacionados

Descripción

The CN350, CN360 and CN370 Series controllers are designed for economical and easy use. Models are available with digital, deviation, or non-indicating display, for J, K, R, and S thermocouples or 100 . platinum RTD input. The small 1.88" (48 mm) square face, 1.77" square cutout ( 1 /16 DIN) and short depth behind panel (3.54", 90 mm) help save panel space and installation costs. All models have a digital thumbwheel for adjusting the setpoint. The CN370 Series models provide continuous digital display of the process temperature. The CN360 Series indicate whether the process temperature is within ±1.5% full scale of the setpoint or above or below setpoint. The CN350 Series are non-indicating. These controllers are time proportional with manual reset, and can be converted to ON-OFF control by changing internal jumpers. The proportional band is fixed at 4%.
Two types of output are available. A 2.5 Amp (SPDT) mechanical relay is for use with systems which can use a 30-second cycle time. With an external solid state relay, loads to 5 Amps can be accommodated. For systems which require a faster cycle time, the dc solid state driver output should be used. This has a cycle time of approximately 3 seconds and can control high ac loads using a dc controlled solid state relay.
Hacer Pedido(Especifique el Número de Modelo)
Número de parte/Desc.
Cant.
Descripción
Relay Output Model Controllers
Indicating Controllers
Quick Ship
CN371-JF3-24VDC
Consultar Ventas  
Disponible en: 
 
 
Time Proportional Controller, J Input, 0-499 Degree Fahrenheit Range, DC Pulse Output with an Indicating Display. 24 Vdc Power.
Deviation Controllers
Quick Ship
CN361-P1F4
Consultar Ventas  
Disponible en: 
 
 
Time Proportional Controller, RTD Input, 0-799 Degree Fahrenheit Range, Mechanical Relay Output with an Deviation Display.
DC PULSE OUTPUT UNITS
Non-Indicating Controllers
Quick Ship
CN352-P2CX
Consultar Ventas  
Disponible en: 
 
 
Time Proportional Controller, RTD Input, 0-99.9 Degree Celcius Range, DC Pulse Output, Non-Indicating.
Quick Ship
CN352-P1F2
Consultar Ventas  
Disponible en: 
 
 
Time Proportional Controller, RTD Input, 0-399 Degree Farenheit Range, DC Pulse Output, Non-Indicating.
Quick Ship
CN352-P1C2
Consultar Ventas  
Disponible en: 
 
 
Time Proportional Controller, RTD Input, 0-399 Degree Celcius Range, DC Pulse Output, Non-Indicating.
Quick Ship
CN352-JC2
Consultar Ventas  
Disponible en: 
 
 
Time Proportional Controller, J Input, 0-399 Degree Celcius Range, Mechanical Relay Output with an Non-Indicating Display.
Quick Ship
CN352-KC2
Consultar Ventas  
Disponible en: 
 
 
Time Proportional Controller, K Input, 0-399 Degree Celcius Range, Mechanical Relay Output with an Non-Indicating Display.
Todas las cantidades que se muestran en MXN
Nota: For low voltage 24 Vdc power, add suffix "-24VDC", no additional charge. Low voltage power is not available on dc Pulse models: CN372, CN362 or CN352 series. Each controller is supplied with user’s manual.

Generador de Número de Parte

Construya su Número de Parte Abajo
Opciónes de Descripción:


(1) Display Option seleccionar de:
5 para Non-Indicating
6 para Deviation Display
7 para Digital Readout Indication

(2) Output Option seleccionar de:
1 para Mechanical Relay
2 para DC Pulse Driver

(3) Sensor Type and Temperature Range seleccionar de:
JC2 para J Thermocouple 0 to 399 Degrees C
JF3 para J Thermocouple 0 to 499 Degrees F
JF4 para J Thermocouple 0 to 799 Degrees F
KC2 para K Thermocouple 0 to 399 Degrees C
KC5 para K Thermocouple 0 to 999 Degrees C
KC6 para K Thermocouple 0 to 1199 Degree C
KF5 para K Thermocouple 0 to 999 Degrees F
KF8 para K Thermocouple 0 to 1999 Degree F
RC7 para R Thermocouple 0 to 1699 Degrees C
RF9 para R Thermocouple 0 to 2999 Degrees F
SC7 para S Thermocouple 9 to 1699 Degrees C
P1C1 para 100 Ohm Platinum RTD -99 to 99 Degrees C
P2CX para 100 Ohm Platinum RTD 0 to 99.9 Degrees C
P1C2 para 100 Ohm Platinum RTD 0 to 399 Degrees C
P1F2 para 100 Ohm Platinum RTD 0 to 399 Degrees F
P1F4 para 100 Ohm Platinum RTD 0 to 799 Degrees F

(4) Low Voltage 24 Vdc Power seleccionar de:
Nada (dejar el campo en blanco) para No Option
-24VDC para 24 Volt dc Power Option
Nota: Todas las combinaciones pueden no ser válidas, revise la hoja de especificaciones para números de parte válidos