En México: 01800-953-00-93
Correo de Ventas:ventas@mx.omega.com

Process Scanners Wall-Mount 4- and 7-Zone

DPS3304, DPS3307, DPS3314, DPS3317

Process Scanners Wall-Mount 4- and 7-Zone | DPS3304, DPS3307, DPS3314, DPS3317

Process Scanners Wall-Mount 4- and 7-Zone

MXN33,985.00 DPS3307TC-2

2 años de garantía
  • Selectable Temperature Units—°C or °F
  • Process Readings in Engineering Units
  • Fully Programmable via Front Keys
  • Programmable Automatic Scanning
  • Hold Feature to Dwell on Any Selected Channel
  • Thermocouples, RTDs, and Thermistors
  • Simple Scaling for Voltage, Current, and Millivolt Inputs
  • Programmable Limit for Each Channel
  • Built-In Buzzer to Sound Alarm (Optional)
  • Visual Indication of Channel Alarm Status
  • Power Line Filter for High Reliability
  • Protection from Dust and Moisture
  • Sealed Enclosure with Clear Plastic Front
Controladores, medidores y dispositivos de conmutación - Ver Productos Relacionados

Descripción

Housed in a wall-mount, watertight plastic enclosure, the DPS3300 Series scanners offer highly functional multichannel scanning with a number of very useful features. Tasks that formerly required multiple monitors can now be accomplished by using a single unit. Signals from 7 different transducers are carried into conveniently located screw terminals that are accessed through a sealed plastic cover. The unit automatically scans each channel, displaying the channel number and its process reading.

Signals from thermocouples, RTDs, and thermistors are linearized and can be displayed in °C or °F. Current, voltage, and millivolt signals are easily scaled for indicating the process in specified engineering units. Up to 7 different processes can be displayed on a single scanner, and each channel can be assigned a 3-digit, alphanumeric engineering unit (psi, ft, etc.). Channels are sequentially displayed for a programmed length of time; with the hold feature, the display can be held indefinitely on any one channel.

The DPS3300 has multiple display modes and can be programmed to scan all channels, display the channel with the highest or lowest reading, process deviation from a pre-programmed setpoint, and display differentials between channels. The DPS3300 can also run merely as a timer.

Additional features include min/max readings and rate of change for all channels (from a pre-programmed setpoint). A control relay or open-collector output for each channel is available as an option. A built-in buzzer (available with output option) sounds an alarm whenever a limit is reached. Visual indication of relay output status is given by LEDs.

SPECIFICATIONS
Input Types: J, K, T, E, R, S, B, Pt100 RTD and thermistor [2252 Ω @ 25°C (77°F)], 4 to 20 mA, 0 to 100 mV, 0 to 5 Vdc, 0 to 10 Vdc
Cold-Junction Compensation Error: ±1°C max [10 to 40°C (50 to 104°F)]
Open Thermocouple Indication: "HELP" displayed.
Custom Inputs Available: Consult Engineering
Scan Rate: Fixed-2 channels per second
Display Time: Programmable from 1 to 999 seconds
Reliability/Accuracy:
    Calibration: NIST traceable (temperature)
    Resolution: 1°C or F
    Thermistor: 0.1°C/0.2°F
    Process: 9999, 999.9, 99.99, 9.999
    Selectable Temperature Units: Celsius or Fahrenheit
Analog-to-Digital Conversion: 20,000 count A/D converter; dual-slope integrating converter
Conversion Rate: 7 conversions per second (typical)
Display: Red 7-segment LED display, 7 digits, 20 mm (0.8") high; negative polarity indication
    Over-Range Indication: "HELP"
    Display Test: Briefly indicates 8.8.8.8.8.8.8 on power-up
Elapsed Time: Displayed in hours, minutes and seconds
    Format: HH.MM.SS
Power Options: 120 Vac -60 Hz (standard) 220 Vac-50 Hz (optional) 8 to 15 Vdc @ 900 mA (optional
Relay/Open-Collector Output (Optional):
    Relays: SPST, 1 A @ 28 Vdc or 0.5 A @ 120 Vac
Open Collector Output: 50 mA max (internal 5 Vdc source)
Dimensions/Enclosure:
    Case: 192 W x 160 H x 103 mm D (7.55 x 6.29 x 4.05")
    Material: Polystyrene with crystal-clear polycarbonate lid
Ingress Protection: Up to IP65 (DIN standard)
Weight: 1.4 kg (3 lb)
Hacer Pedido(Especifique el Número de Modelo)

Lo que han comprado otras personas: Cuando vea este icono, haga clic sobre él para abrir la lista de productos que otras personas han comprado al adquirir este modelo

Número de parte/Desc.
Cant.
Descripción
  
DPS3307TC-3
MXN40,910.00
Disponible en: Disponible
 
Dedicated input 7 -zone scanner, T/C input, 7 relay outputs
  
DPS3314TC-2
MXN33,985.00
Disponible en: 4 Semanas
 
Programmable input 4-zone scanner, 8 to 15 Vdc
  
DPS3317TC-2
MXN38,455.00
Disponible en: 4 Semanas
 
Programmable input 7-zone scanner, 8 to 15 Vdc
Accessories
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloRELAY-URM-400
RELAY-URM-400
MXN7,295.00
Disponible en: 4 Semanas
 
Universal 15 A mechanical 4-relay module
Todas las cantidades que se muestran en MXN

Generador de Número de Parte

Construya su Número de Parte Abajo
Opciónes de Descripción:


(1) Model Number seleccionar de:
3304 para Dedicated input 4-zone scanner
3307 para Dedicated input 7-zone scanner
3314 para Programmable input 4-zone scanner
3317 para Programmable input 7-zone scanner

(2) Input Codes seleccionar de:
TC para J K T E 4 to 20 mA 0 to 10 Vdc - J K T E
RTD para RTD 4 to 20 mA 0 to 10 Vdc - RTD
TH para Thermistor 4 to 20 mA 0 to 10 Vdc - Thermistor
R para R T/C 4 to 20 mA 0 to 10 Vdc - R T/C
S para S T/C 4 to 20 mA 0 to 10 Vdc - S T/C
B para B T/C 4 to 20 mA 0 to 10 Vdc - B T/C
MV para 0 to 100 mV
P para 100 mV 4 to 20 mA 0 to 10 Vdc
V para 0 to 10 Vdc
C para 4 to 20 mA

(3) Power Options seleccionar de:
Nada (dejar el campo en blanco) para 120 Vac - 60 Hz (standard)
-1 para 240 Vac
-2 para 8 to 15 Vdc

(4) Output Options seleccionar de:
Nada (dejar el campo en blanco) para None
-3 para 7 relay outputs (7-channel units)
-4 para 7 open-collector outputs (7-channel units)
-5 para 4 relay outputs (4-channel units)
-6 para 4 open-collector outputs (4-channel units)
Nota: Todas las combinaciones pueden no ser válidas, revise la hoja de especificaciones para números de parte válidos
We noticed you are from the US. Visit your local site for regional offers and live support.