FMA-2600 SERIES
Mass Flow Controllers with 20+ Gas Select Function
Ver Todas los Modelos Abajo
-
130+ Gas Calibrations, Including: He, O2 , Neon, N2O, N2, Air, Argon, CO, CO2, Methane, Ethane, Propane, Butane, Acetylene, Ethylene, H2
-
Pressure, Temperature, Volumetric & Mass Flow Simultaneously Displayed
-
Easy Operator Push Button Interface
-
NIST Traceability Standard
-
Full Scale Ranges from 0.5 SCCM to 3000 LPM
-
Response Time of 100 milliseconds Typical
-
Turndown Ratio of 100:1 Typical
-
Position Insensitive
-
Accuracy of ±1% Full Scale
-
RS232 Standard
-
No Warm Up Time
Caudalímetros másicos electrónicos - Ver Productos Relacionados
Todas las cantidades que se muestran en MXN
Nota: Comes complete with 24 Vdc universal power supply, 1.8m (6') cable, 8-pin male Mini- DIN connector, operator's manual, and NIST certificate.
Standard units are calibrated to air @ 5 psig for 0 to 1 LPM, 15 psig for 2 to 10 LPM, 30 psig for 20 to 100 LPM, and 50 psig for 200 LPM and greater.
For custom calibrations, add "-(*)" to the model number, no additional cost. *Specify gas, and inlet/outlet or backpressure for custom calibrations.
Calibrations done at ambient (25C/77F) temperature only.
To replace the standard RS232 communications with RS485, add suffix "-RS485" to the model number, add $120 to the price.
Standard input is 0-5V, for optional 4-20 mA input add suffix "-IN" to the model number, no additional cost.
Standard output is scaled to the mass flow rate. For volumetric flow rate as standard output add suffix "-VOL" to the model number. For "-VOL" controllers the control loop is set to volumetric as standard.
Optional secondary output are scaled the same as the primary output scale. For an alternate output scale add suffix "-V2T" for voltage scaled for temperature, "-I2T" for current scaled for temperature, "-V2P" for voltage scaled for pressure or "-I2P" for current scaled for pressure, no additional cost.
For units scaled in SCFH, add suffix "-SCFH" to model number, no additional cost. Please specify the desired range in SCFH.
For totalizer option, add suffix "-TOT" to the model number, add $120 to the price. Please specify resolution.
This is a 6-digit counter. Examples: For totalizing in liters with 1/100 liter resolution, the max count would be 9999.99. For totalizing in liters with 1 liter resolution, the max count would be 999999.
For a Remote Display, add suffix "-RD-*FT" to the model number, add $210 to the price. Replace the * in the suffix with the required length in whole feet, the maximum length is 3.6576 m (12'). Please note the optimum distance in feet is between 2.7 to 3 m (9 to 10').
Ethernet/IP, DeviceNet, Modbus and Profibus communications are also available for an additional charge.
Ejemplo de pedido: (1) FMA-2601A-I2 10-32 Thread Mass Gas Flow Controller with optional second channel output of 4-20mA, MXN94,665.00
Generador de Número de Parte
Construya su Número de Parte Abajo
Opciónes de Descripción:
(1)
Flow Range seleccionar de:01 para 0.5 SCCM
02 para 1 SCCM
14 para 2 SCCM
15 para 5 SCCM
03 para 10 SCCM
16 para 20 SCCM
04 para 50 SCCM
17 para 100 SCCM
18 para 200 SCCM
19 para 500 SCCM
20 para 1 SLM
05 para 2 SLM
06 para 5 SLM
07 para 10 SLM
08 para 20 SLM
09 para 50 SLM
10 para 100 SLM
11 para 250 SLM
12 para 500 SLM
13 para 1000 SLM
21 para 1500 SLM
22 para 2000 SLM
23 para 3000 SLM
(2)
Output seleccionar de:Nada (dejar el campo en blanco) para None
-I para 4 to 20 mA output
-I2 para Two 4 to 20 mA outputs
-V2 para Two 0 to 5V Outputs
-I2T para Two 4 to 20 mA outputs second output for temperature
-V2T para Two 0 to 5V outputs second output for temperature
-I2P para Two 4 to 20 mA outputs second output for pressure
-V2P para Two 0 to 5V outputs second output for pressure
-VOL para Volumetric flow rate as standard output
(3)
Integrated positive shut-off valve seleccionar de:Nada (dejar el campo en blanco) para Standard
-P para Integrated positive shut-off valve (only available on models up to 20 SLM)
(4)
Input seleccionar de:Nada (dejar el campo en blanco) para 0 to 5V
-IN para 4 to 20 mA input
(5)
RS485 seleccionar de:Nada (dejar el campo en blanco) para RS232
-RS485 para RS485
(6)
SCFH seleccionar de:Nada (dejar el campo en blanco) para Standard
-SCFH para Units scaled in SCFH
(7)
Totalizer seleccionar de:Nada (dejar el campo en blanco) para Standard
-TOT para Totalizer
Nota: Todas las combinaciones pueden no ser válidas, revise la hoja de especificaciones para números de parte válidos