1/32 DIN Models iS32, Strain and Process Meters and Controllers

I-STRAIN

1/32 DIN Models iS32, Strain and Process Meters and Controllers | I-STRAIN

MXN9,720.00 DPIS32

5 años de garantía CE
  • High Quality
  • FREE 5-Year Warranty
  • High Accuracy 0.03% Rdg
  • User Friendly, Simple to Configure
  • Free Software
Instrumentación para la medición de presión y tensión - Ver Productos Relacionados

Descripción

The "iS" series of meter/controllers can measure a wide variety of strain gage bridge and DC voltage intputs for all common load cells, pressure transducers, and most any strain gauge type of transducer. It is the first instrument of its kind, offering a wealth of powerful features and performance in an amazingly compact 1/32 DIN package or a 1/8 DIN package with 0.83" (21mm) high digits. The iS series handles input ranges of 0-100 mV, -100 mVdc to 1 Vdc, 0-10 V and 0-20mA. The iS series is easy to configure and scale to virtually any engineering units using the push buttons on the front panel, or using personal computer with the optional serial communications and free configuration software. The serial communications option includes both RS-232 and RS-485 on one instrument, and the straightforward OMEGA ASCII communications protocol, as well as MODBUS protocol. The iS series includes built-in excitation for transducers, selectable as 10 V at 100 mA or 5 V at 60 mA. The CNiS series controllers feature a choice of two optional outputs: Form C SPDT (single pole double throw) mechanical relays, solid state relays, DC pulse, and programmable analog output selectable for either a control function or retransmission of the process value. The iS series features the iSeries totally programmable color display that can change colors between Green, Amber, and Red at any setpoint or alarm point.

SPECIFICATIONS
Input Ranges: 0-100 mV, -100 mVdc to 1 Vdc, 0-10 V, 0-20 mA
Isolation: 354 V peak per IEC spacing
NMR: 60 dB
CMR: 120 dB
Input Impedance: 10 MOhms for 100 mV input 1 MOhm for 1 or 10 V input 5 Ohms for 20 mA current input
Display: 4 digits, 9 segments tri-color LED
Digit Height: iS32;10.2 mm (.4")
iS8; 21 mm (0.83")
Analog-to-Digital technique: Dual slope
Internal A/D Resolution: 15 bits
Read rate: 3 / sec
Polarity: Automatic
Max Error Strain/Process: ±0.03% rdg.
Span tempco.: ± 50 ppm / C
Step response: 1-2 sec.
Warmup to rated accuracy: 30 min.
Analog Output (optional): 0-10 V, 4-20 mA, can be used as Retransmission or PID Control.
Excitation Voltage: 10 V @ 100 mA, 5 V @ 60 mA
Power: 90-240 Vac 50-400 Hz or 90-375 Vdc, 4 W (optional) 24 Vac 50-400 Hz or 12-36 Vdc, 5 W
Dimensions:iS32: 25.4 H x 48 W x 127 D mm (1.0 x 1.89 x 5.0")
iS8: 48 H x 96 W x 127 D mm (1.89 x 3.78 x 5.0")
Weight:iS32; 127 g (0.28lb)
iS8; 295 g (0.65lb)
Approvals: CE per EN50081-1, EN50082-2, EN61010-1

For full product specifications view pdf file in "Related Links" below

Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.
Hacer Pedido(Especifique el Número de Modelo)
Número de parte/Desc.
Cant.
Descripción
DPiS32
MXN9,720.00
Disponible en: Disponible
 
1/32 DIN i Series strain gage meter with 90-240 Vac/dc power
DPiS32-C24
MXN12,640.00
Disponible en: 6 Semanas
 
1/32 DIN i Series strain gage meter with RS-232 & RS-485 communications and 90-240 Vac/dc power
DPiS32-DC
MXN10,855.00
Disponible en: 6 Semanas
 
1/32 DIN i Series strain gage meter with 24 Vac or 12-36 Vdc power
DPiS32-C24-DC
Consultar Ventas  
Disponible en: 
 
 
1/32 DIN i Series strain gage meter with RS-232 & RS-485 communications and 24 Vac or 12-36 Vdc power
DPiS8
MXN12,420.00
Disponible en: 6 Semanas
 
1/8 DIN i Series strain gage meter with 90-240 Vac/dc power
DPiS8-C24
MXN15,475.00
Disponible en: 6 Semanas
 
1/8 DIN i Series strain gage meter with RS-232 & RS-485 communications and 90-240 Vac/dc power
DPiS8-DC
MXN13,730.00
Disponible en: 6 Semanas
 
1/8 DIN i Series strain gage meter with 24 Vac or 12-36 Vdc power
DPiS8-C24-DC
Consultar Ventas  
Disponible en: 
 
 
1/8 DIN i Series strain gage meter with RS-232 & RS-485 communications and 24 Vac or 12-36 Vdc power
CNiS822
MXN15,155.00
Disponible en: 6 Semanas
 
1/8 DIN i Series strain gage controller with two solid state relays and 90-240 Vac/dc power
CNiS822-C24
Consultar Ventas  
Disponible en: 
 
 
1/8 DIN i Series strain gage controller with two solid state relays, RS-232 & RS-485 communications and 90-240 Vac/dc power
CNiS3222
MXN11,860.00
Disponible en: 6 Semanas
 
1/32 DIN i Series strain gage controller with two solid state relays and 90-240 Vac/dc power
CNiS3222-C24
Consultar Ventas  
Disponible en: 
 
 
1/32 DIN i Series strain gage controller with two solid state relays, RS-232 & RS-485 communications and 90-240 Vac/dc power
Todas las cantidades que se muestran en MXN
Nota: Transducer excitation not available on models with serial communications ("-C24") option.

Generador de Número de Parte

Construya su Número de Parte Abajo
Opciónes de Descripción:


(1) DIN Cutout seleccionar de:
32 para 32nd DIN
8 para 8th DIN

(2) Control Outputs #1 seleccionar de:
2 para Solid State Relay/0.5 A at 120/240 Vac continuous
3 para SPDT Relay
4 para Pulsed 10 Vdc at 20 mA
5 para Analog Output 0 to 10 Vdc

(3) Control Outputs #2 seleccionar de:
2 para Solid State Relay/0.5 A at 120/240 Vac continuous
3 para Relay SPDT 3A at 120/3 A at 240 Vac
4 para Pulsed Driver 10 Vdc at 20 mA /for use with external SSR

(4) Serial Communications seleccionar de:
Nada (dejar el campo en blanco) para Standard Unit
-C24 para Isolated RS-232 and RS-485 300 to 19.2 k baud

(5) Power Supply seleccionar de:
Nada (dejar el campo en blanco) para Standard Power (90 to 240 Vac/dc @ 50 to 400 Hz)
-DC para Low Voltage Power (24 Vac or 12 to 36 Vdc)
Nota: Todas las combinaciones pueden no ser válidas, revise la hoja de especificaciones para números de parte válidos

Manuales de Productos:

Descarga Process/Strain Gauge Monitor Manual
Descarga Process/Strain Gauge Controller Manual
Descarga i Series Monitor Quick Start Manual
Descarga i Series Monitor Quick Start Manual
Descarga i Series Controller Quick Start Manual
Descarga i Series Controller Quick Start Manual