Omega’s LC60 Series is a low cost, highly accurate, single point load cell, ideal for OEM applications such as electronic scales and weighing machines. The single point design is highly resistant to eccentric loading, allowing direct mounting to the scale base and weighing platform. The LC60 Series features a moisture-proof sealant and is available in ranges from 600 grams to 200 kilograms.
Specifications OIML R60 Accuracy Class: LC61: C3D LC62 and LC63: C3 Output Sensitivity (= FS, mV/V): LC61: 1.0 ±0.1 LC62 and LC63: 2.0 ±0.2 Maximum Number of Load Cell Intervals(nLC): LC61: 2500 LC62 and LC63: 3000 Ratio of Minimum LC Verification Interval Y = Emax/vmin: LC61: 5000 LC62 and LC63: 10000 Combined Error: LC61: ±0.028 %FS LC62 and LC63: ±0.02 %FS Minimum Dead Load: 0% FS Safe Overload: 120% FS Maximum Overload: 150% FS Zero Balance: ±2.0% FS Excitation, Recommended Voltage: 5 to 12 VDC Excitation Maximum: 18(VDC) Input Resistance Ω: 406 ±6 Output Resistance Ω: 350 ±3 Insulation Resistance MΩ: ≥ 5000 (50 VDC) Compensated Temperature: -10 to 40ºC (14 to 104ºF) Operating Temperature: -35 to 65ºC (-31 to 149ºF) Storage Temperature: -40 to 70ºC (-40 to 158ºF) Element Material: Aluminum Recommended Bolt Size/Torque (Nm): LC61: M3/1.5 LC62: < 30kg: 6, LC63: M6:10 Ingress Protection (According to EN 60529): IP65
Figure 1 All Dimensions mm
Figure 2
Figure 3
Todas las cantidades que se muestran en MXN Nota: For dimensions refer to diagrams above.