En México: 01800-953-00-93
Correo de Ventas:ventas@mx.omega.com

Liquid Level Transmitters Suitable For Levels to Six Feet - Discontinued

LVR20/30 Series

Liquid Level Transmitters Suitable For Levels to Six Feet - Discontinued | LVR20/30 Series

Ver Todas los Modelos Abajo

1 año de garantía
  • Rugged 316SS Construction
  • 4-20 mA or Resistance Output
  • Immune to Changes of Density and Dielectric
  • 1 /4 " Resolution

Descripción

Discontinued, replaced by LVR500 Series.

.

The LVR20 and LVR30 Series continuous liquid level sensors operate on a basic voltage divider network principle. As the float rises, a magnet in the float closes a series of reed switches in sequence which varies the tapped-off portion of the voltage divider resistor network. The LVR20 has the basic voltage divider output—the regulated DC voltage input equals the maximum voltage output. The LVR20 has a nominal 1,200 resistance; thus, with a 10 Vdc supply, 8.3 mA of current are required.

The DPF52 or DP24-E panel meters can be used to power and display the resistance from the LVR20; when relays are required, the DP25E-A meter can be used. For maximum accuracy, the readout device for the LVR20 should be zero and span adjusted after wiring is completed to compensate for any effects due to the resistance of the lead wires. The LVR20 can also be made intrinsically safe when used with OMEGA’s intrinsic safety barriers and when properly powered. The LVR30 Series is provided with a signal conditioner to provide a 4-20 mA output when powered by 10-30 Vdc. The LVR30 Series cannot be made intrinsically safe.

All LVR30 units are supplied with a J-box with screw terminal connections. All LVR20 units are supplied without a J-box with 24 inches of bare wire coming out of the top of the unit with a 1?2 MNPT conduit connection. All LVR20 and LVR30 Series units can be wired for increasing output with either increasing or decreasing height of liquid; standard output is increasing output with increasing height. For other lengths, adaptor systems are available. They consist of two parts: the LVR-C coupling (2 x 2 FNPT) and an LVR-A pipe nipple (2 x 2 MNPT) of various lengths to change the insertion depth of the LVR20 or LVR30 sensor. When using the adaptors, a zero offset is introduced into the output signal which must be compensated for in the readout device (for example, the mA signal will not go down to 4 mA, nor will the voltage output go down to zero).

Retaining clip pliers are required to remove the float when using the adaptor system.
Hacer Pedido(Especifique el Número de Modelo)

Lo que han comprado otras personas: Cuando vea este icono, haga clic sobre él para abrir la lista de productos que otras personas han comprado al adquirir este modelo

Número de parte/Desc.
Cant.
Descripción
Isolated 4 to 20 mA Output and J-box
  
LVR31
Consultar Ventas  
Disponible en: 
 
 
1 ft 4-20 mA output
  
LVR33
Consultar Ventas  
Disponible en: 
 
 
3 ft 4-20 mA output
  
LVR34
Consultar Ventas  
Disponible en: 
 
 
4 ft 4-20 mA output
  
LVR35
Consultar Ventas  
Disponible en: 
 
 
5 ft 4-20 mA output
  
LVR36
Consultar Ventas  
Disponible en: 
 
 
6 ft 4-20 mA output
Voltage Divider (Voltage In = Voltage Out)
  
LVR21
Consultar Ventas  
Disponible en: 
 
 
1 ft long indicating length, Voltage Divider, Voltage in = Voltage out
  
LVR22
MXN29,120.00
Disponible en: Disponible
 
2 ft long indicating length, Voltage Divider, Voltage in = Voltage out
  
LVR23
Consultar Ventas  
Disponible en: 
 
 
3 ft long indicating length, Voltage Divider, Voltage in = Voltage out
  
LVR24
Consultar Ventas  
Disponible en: 
 
 
4 ft long indicating length, Voltage Divider, Voltage in = Voltage out
  
LVR25
Consultar Ventas  
Disponible en: 
 
 
5 ft long indicating length, Voltage Divider, Voltage in = Voltage out
  
LVR26
Consultar Ventas  
Disponible en: 
 
 
6 ft long indicating length, Voltage Divider, Voltage in = Voltage out
Accessories
  
LVR-A4
MXN1,020.00
Disponible en: 5 Semanas
 
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 4" indicating length change
  
LVR-A6
MXN1,380.00
Disponible en: 5 Semanas
 
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 6" indicating length change
  
LVR-A6
MXN1,380.00
Disponible en: 5 Semanas
 
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 6" indicating length change
  
LVR-A7
MXN1,490.00
Disponible en: 5 Semanas
 
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 7" indicating length change
  
LVR-A9
MXN1,725.00
Disponible en: 5 Semanas
 
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 9" indicating length change
  
LVR-A11
MXN1,825.00
Disponible en: 5 Semanas
 
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 11" indicating length change
  
LVR-A13
MXN2,485.00
Disponible en: 5 Semanas
 
Pipe Nipple, 304 SS, 150 lb fittings, 2 x 2 MNPT, 13" indicating length change
  
LVR-C
MXN3,405.00
Disponible en: 5 Semanas
 
150 lb 304 SS Coupling, 2 x 2 FNPT
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloU24Y175
U24Y175
Consultar Ventas  
Disponible en: 
 
 
24 Vdc, 175 mA Power Supply
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloDPI8
DPI8
MXN10,975.00
Disponible en: 6 Semanas
 
1/8 DIN Display Panel Meter
Todas las cantidades que se muestran en MXN
Nota: Units come complete with operator's manual.

LVR20 series is supplied without J-Box.


Ejemplo de pedido: (1) DPI8 1/8 DIN display panel meter, MXN10,975.00  plus (1) LVR22 316 SS level sensor with 2 ft long indicatating length, MXN29,120.00  plus (1) U24Y175 24 Vdc power supply, MXN5,630.00, MXN10,975.00 + 29,120.00 + 5,630.00 = MXN45,725.00
We noticed you are from the US. Visit your local site for regional offers and live support.