Memory: 21,845 Humidity and 21,845 Temperature Reading
Programmable Start Time
Dew Point and Vapor Concentration Calculated in Software
Miniature Size
User Calibration Through Software
Real Time Operation
Descripción
This product is no longer available please see
OM-CP-RHTEMP101A as a direct substitute
The OM-CP-RHTEMP101
and OM-CP-RHTEMP110 are
miniature, battery powered, stand-alone,
temperature and humidity dataloggers.
These all-in-one compact, portable,
easy to use devices will measure and
record up to 21,845 humidity and
21,845 temperature measurements.
These dataloggers are a major leap
forward in both size and performance.
Its real time clock ensures that all
data is time and date stamped. The
storage medium is non-volatile solid
state memory, providing maximum
data security even if the battery
becomes discharged. Its small size
allows it to fit almost anywhere. Data
retrieval is simple. Plug it into an
empty COM port and our easy to use
software does the rest. The software
converts your PC into a real time strip
chart recorder. Data can be printed in
graphical or tabular format and can be
exported to a text or Microsoft Excel file.
Specifications
TEMPERATURE/HUMIDITY Temperature Sensor: semiconductor Temperature Measurement Range:
-40 to 80°C 1, (-40 to 176°F) 1 Temperature Resolution: 0.1°C Calibrated Accuracy: 0.5°C Specified Accuracy Range:
0 to 50°C Humidity Sensor: semiconductor 4,5 Humidity Measurement Range:
0 to 100% RH Humidity Resolution: 0.5% RH Calibrated Accuracy:
±3 %RH (±2 %RH typical at 25°C) Specified Accuracy Range:
10 to 80% RH, 10 to 40°C 2,3 Humidity Response Time:
90% of change in 60 seconds in slow
moving air
GENERAL SPECIFICATIONS
Readings: 21,845 readings/channel Temperature/Humidity
Calibration: digital calibration is
available through software Calibration Date: Automatically
recorded within device Recording Interval: 30/minute
to 2 day selectable through software Start Time: start time and date are
programmable through software, up to
6 months in advance Real Time Recording: device may
be used with PC to monitor and
record data in real time Temperature Alarm: programmable
high and low limits; when logged
temperature reaches or exceeds
either limit, the LED blinks once/sec. Red Visual Indicator: LED flashes at
selected reading rate or at 1 sec rate
under alarm condition Power: 3.6 V lithium battery included Battery Life: OM-CP-RHTEMP101:
year at 1 min reading rate OM-CP-RHTEMP110:
10 years at 15 min reading rate Time Accuracy: ±1 minute per month at 20°C, RS-232 port not in use Data Format: date and time stamped, °C, °F, °K, °R % RH, mg of water
vapor concentration Computer Interface: PC serial,
RS-232C COM or USB (interfaced cable
required) Communications: OM-CP-RHTEMP101: 2400 baud OM-CP-RHTEMP110: 57600 baud Software: WIN98/NT/2000/XP/VISTA 32-bit (VISTA 32-bit version only; VISTA 64-bit is not supported) Operating Environment:
(-40 to 80°C) 1, -40 to 176°F,
to 95% RH non-condensing Weight: OM-CP-RHTEMP101: 30 g (1 oz) OM-CP-RHTEMP110: 60 g (2 oz) Dimensions: OM-CP-RHTEMP101:
35 H x 55 W x 16 mm D
(1.4 x 2.2 x 0.6") OM-CP-RHTEMP110:
43 H x 69 W x 20 mm D
(1.7 x 2.7 x 0.8" mm)
Todas las cantidades que se muestran en MXN Nota: Operator’s manual and RS-232 cable are included with the OM-CP-IFC110 Windows software (software is required to operate the datalogger and is sold separately).
1 The recommended operating temperature is 0 to 80°C; 2 Humidity accuracy is not specified in condensing environments; 3 Extended exposure to > 90%RH results in a temporary 3 %RH error; 4 The sensor is light sensitive-bright light may effect measurement; 5 Submerging the sensor in any liquid may cause permanent damage.
We noticed you are from the US. Visit your local site for regional offers and live support.