En México: 01800-953-00-93
Correo de Ventas:ventas@mx.omega.com

High Accuracy Pressure Standards, Microprocessor-Based Dual Display, Digital and Analog

PCL-3000

High Accuracy Pressure Standards, Microprocessor-Based Dual Display, Digital and Analog | PCL-3000

Ver Todas los Modelos Abajo

2 años de garantía
  • Switch Selectable Ranges - Absolute or Gage
  • Accuracy ±0.05% FS,
  • Ranges - From 10 to 10,000 psi
  • Automatic Zeroing (No Potentiometer Needed)
  • Self-Calibrating
  • Digital Output RS-232 Optional
  • Integral Stainless Steel Transducer
  • 2-Year Warranty
Instrumentación para la medición de presión y tensión - Ver Productos Relacionados

Descripción

PCL-3000 Series digital pressure standards are specifically designed for use in the manufacture, testing, or calibration of pressure-sensitive devices. Using a patented, bonded foil strain-gage sensor and advanced microcircuitry, these rugged, compact instruments provide simultaneous digital and analog readouts of the pressures applied. Standard front panel switches permit desired pressure range selection, automatic zeroing of the display and actuation of a unique internal self-calibration feature. Each instrument has two displays, digital and analog. The digital display provides precise pressure information and the analog display gives a quick reference to direction and level of pressure.

SPECIFICATIONS
Accuracy: ±0.05% FS max., each range. (Accuracy statement includes linearity, hysteresis and repeatability.)
Operating Temperature: 10 to 43°C (50 to 110°F)
Pressure Media: Any media compatible with 17-4 PH Stainless Steel
Overpressure Capability: 750% FS on lowest range; 300% FS on mid. range; 150% FS on highest range
Display Resolution: Nominally 0.02% FS for each pressure range
Reading Rate: 10/sec
Input Voltage: 117 or 220 Vac ±10%, 50/60 Hz Voltage selected via transformer taps
Pressure Connection: 7/16-20 UNFM
Power Consumption: 8 watts, typical
Nominal Size: 27 W x 12 Hx 25 cm D (10.8 W x 4.9 H x 9.9" D)
Panel Cutout: 26.9 x 12 cm (10.62 x 4.75")
Weight: 2.3 kg (5 lb)
Hacer Pedido(Especifique el Número de Modelo)
Número de parte/Desc.
Cant.
Descripción
PCL-3000A
Consultar Ventas  
Disponible en: 
 
 
Pressure standard with 0-5,000, 0-2,500 and 0-1,000 psia or psig selectable ranges
PCL-3000B
Consultar Ventas  
Disponible en: 
 
 
Pressure standard with 0-1,000, 0-500 and 0-200 psia or psig selectable ranges
PCL-3000C
Consultar Ventas  
Disponible en: 
 
 
Pressure standard with 0-500, 0-250 and 0-100 psia or psig selectable ranges
PCL-3000D
Consultar Ventas  
Disponible en: 
 
 
Pressure standard with 0-100, 0-50 and 0-20 psig selectable ranges with conversion to Inches of Water
PCL-3000E
Consultar Ventas  
Disponible en: 
 
 
Pressure standard with 0-50, 0-25 and 0-10 psig selectable ranges with conversion to Inches of Water
PCL-3000G
Consultar Ventas  
Disponible en: 
 
 
Pressure standard with 0-10,000, 0-5,000 and 0-2,000 psia or psig selectable ranges
Todas las cantidades que se muestran en MXN
Nota: All models come with an NIST traceable calibration certificate.

Generador de Número de Parte

Construya su Número de Parte Abajo
Opciónes de Descripción:


(1) Ranges seleccionar de:
A para 5000/2500/1000 psig and psia
B para 1000/500/200 psig and psia
C para 500/250/100 psig and psia
D para 100/50/20 psig with conversion to InH2O
E para 50/25/10 psig with conversion to inH2O
G para 10000/5000/2000 psig and psia

(2) Options seleccionar de:
para no options leave blank
-1 para Isolated analog output (0-10vdc or 4-20 ma)
-4 para RS232 simplex output
-5 para Peak hold
-7 para Battery option (excludes bargraph display)
-9 para Panel mounting kit
-10 para Freeze mode for testing pressure switches
Nota: Todas las combinaciones pueden no ser válidas, revise la hoja de especificaciones para números de parte válidos
We noticed you are from the US. Visit your local site for regional offers and live support.