Carrito de Compra  |  Contacto  |  Ayuda  |  Correo electrónico  | 
En México: 01800-953-00-93
Fuera de México:+52 (81) 8335-3774

RTD Probe with Insulated Wire and BX Armored Cable

PR-10-BX

RTD Probe With Insulated Wire And BX Armored Cable
 | PR-10-BX

RTD Probe With Insulated Wire And BX Armored Cable

MXN3,750.00 PR-10E-3-100-1/4-6-BX

  • Low temperature range: -50 to 250°C (-58 to 482°F)
  • High temperature range: -50 to 450°C (-58 to 842°F)
  • Extreme temperature range: -200 to 600°C (-328 to 1112°F)
  • Class A accuracy conforming to IEC 60751
  • Standard probe lengths: 2, 3, 4, 6, 9, 12, 18 and 24 in.
  • 2, 3, and 4-wire lead wire styles
  • PT100 and PT1000 RTD element
  • Stripped-end leads with other cold-end termination options
  • Leads covered with BX armored cable
Sondas, elementos y asambleas RTD (PT100) - Ver Productos Relacionados

Descripción

Omega's "BX" armor PT100 or PT1000 RTD probe is designed for resistance to abrasion and snagging in processes where the lead wire is subject to sharp objects, or where the wire is being moved continually. The BX armored cable is placed over PFA wire (for the "Low" temp version and "Extreme" temp version; or fiberglass wire (for the "High" version).
Hacer Pedido(Especifique el Número de Modelo)
Número de parte/Desc.
Cant.
Descripción
Quick Ship
PR-10E-3-100-1/4-6-BX
MXN3,750.00
Disponible en: 4 Semanas
 
3-wire RTD with BX cable, 6 in. length
Quick Ship
PR-10E-3-100-1/4-4-120-BX
MXN8,530.00
Disponible en: 2 Semanas
 
3-wire RTD with BX cable, 4 in. length
Quick Ship
PR-10H-3-100-1/4-4-BX
MXN3,595.00
Disponible en: 4 Semanas
 
3-wire RTD with BX cable, 4 in. length
Quick Ship
PR-10H-3-100-1/4-6-BX
MXN2,740.00
Disponible en: 4 Semanas
 
3-wire RTD with BX cable, 6 in. length
Quick Ship
PR-10L-3-100-1/4-6-BX
MXN2,740.00
Disponible en: 2 Semanas
 
3-wire RTD with BX cable, 6 in. length
Quick Ship
PR-10L-3-100-1/8-12-BX
MXN3,000.00
Disponible en: 2 Semanas
 
3-wire RTD with BX cable, 12 in. length
Todas las cantidades que se muestran en MXN

Generador de Número de Parte

Construya su Número de Parte Abajo
Opciónes de Descripción:


(1) RANGE seleccionar de:
L para L=LOW (-50 to 250°C)
H para H=HIGH (-50 to 450°C)
E para E=EXTREME (-200 to 600°C)

(2) NUMBER OF WIRES seleccionar de:
2 para 2 WIRE
3 para 3 WIRE
4 para 4 WIRE

(3) OHMS seleccionar de:
100 para 100 OHMS
1000 para 1000 OHMS

(4) SHEATH DIAMETER seleccionar de:
1/8 para 1/8" DIAMETER
3/16 para 3/16" DIAMETER
1/4 para 1/4" DIAMETER

(5) SHEATH LENGTH seleccionar de:
2 para 2 INCHES
3 para 3 INCHES
4 para 4 INCHES
6 para 6 INCHES
9 para 9 INCHES
12 para 12 INCHES
18 para 18 INCHES
24 para 24 INCHES

(6) COLD END TERMINATION seleccionar de:
Nada (dejar el campo en blanco) para stripped leads
-RDXL6SD-CONN para connector for RDXL6SD datalogger
-TA3F para 3-pin DIN connector
-TA4F para 4-pin DIN connector
-HH804-CONNECTOR para DIN connector for use with HH-804 RTD meter
-LUG para Spade Lugs
-MTP para 3-pin mini connector
-OTP para 3-pin standard connector
Nota: Todas las combinaciones pueden no ser válidas, revise la hoja de especificaciones para números de parte válidos
Did you know Omega has an office in the United States with local pricing and live engineers to support you in your time zone?