En México: 01800-953-00-93
Correo de Ventas:ventas@mx.omega.com

Ultra High Stability Thin Film Differential Pressure Transducer

PX1006

Ultra High Stability Thin Film Differential Pressure Transducer | PX1006

Ver Todas los Modelos Abajo

  • High Accuracy High Stability Wet/Dry Differential Pressure
  • All Stainless Steel Body for Aerospace or Harsh Industrial Environments
  • High Overpressure Capability
  • Broad Compensated Temperature Range
  • Shock and Vibration Resistant
  • NIST
Transductores de presión - Ver Productos Relacionados

Descripción

The PX1006 Series wet-dry, differential pressure transducers are high stability unidirection differential pressure transducers utilizing a sputtered strain gage assembly. The sputtering method produces an ultra stable high temperature sensor that can withstand high shockThe PX1006 wet/dry differential pressure transducers are highstability aerospace units that use a sputtered strain gage assembly. The sputtering method produces an ultra-stable high-temperature sensor that can withstand high shock and vibration environments. The wet chamber is all stainless steel and is compatible with most industrial fluids. The reference chamber is limited to dry, non-corrosive, nonconductive fluids and gases.

SPECIFICATIONS
mV/V Output
ELECTRICAL
Excitation: 5 Vdc
Output: 15 mV nominal, 13 mV minimum
Bridge Resistance: 350 Ω nominal
Zero Balance: 0 mV ±2% FSO
Input Resistance: 400 Ω nominal
Output Resistance: 400 Ω nominal

PERFORMANCE
Accuracy: ±0.25% FSO linearity, hysteresis and repeatability combined
Hysteresis: <0.1% FSO
Repeatability: <0.05% FSO Zero Shift with Line Pressure:
Line Pressure <3 psia: <1.5%
Line Pressure 3 to 15 psia: <0.25%
Line Pressure >15 psia: <2.5% Sensitivity Shift with Line Pressure: <0.5% per 100 psi

ENVIRONMENTAL
Operating Temp Range: -54 to 149°C (-65 to 300°F)
Compensated Temp Range: -54 to 121°C (-65 to 250°F)
Thermal Effects:
Zero: ±0.009% FSO/¨¬C (±0.005% FSO/°F)
Span: ±0.009% rdg/¨¬C (±0.005% rdg/°F)
Full Scale Output Stability: Less than 0.05% FSO for 2 hr at room temperature. Less than 0.10% FSO for 2 hr at 121°C (250°F).
Zero Stability: Less than 0.05% FSO for 2 hr at room temperature. Less than 0.10% FSO for 2 hr at 121°C (250°F).

PRESSURE
Ranges psid: 15, 25, 50, 100, 300, 500, 1000, 2000, 2500, 5000
Safe Overpressure: 200% rated pressure or 15,000 psi, whichever is less
Burst Pressure: 300% rated pressure or 20,000 psi, whichever is less Reference Chamber Pressure Range: 0 to 400 psi

MECHANICAL
Media Compatibility:
Wet Connection: 17-4 PH stainless steel
Dry Connection: Clean, dry, non-corrosive, non-conductive fluids
Natural Frequency: 50,000 Hz @ 5000 psi decreasing logarithmically to 5000 Hz @ 15 psi
Shock: 100 g half-sine wave for an 11 ms duration
Vibration: 35 g peak sinusoidal vibration from 10 Hz to 2 kHz limited to 1.2" D.A.
Pressure Port: MS33656-4 (7.16-20)
Electrical Connection: PTIH-10-6P (or equal)
Mating Connector: PT06F-10-6S (not included)
Weight: 142 g (5 oz) maximum
Hacer Pedido(Especifique el Número de Modelo)

Lo que han comprado otras personas: Cuando vea este icono, haga clic sobre él para abrir la lista de productos que otras personas han comprado al adquirir este modelo

Número de parte/Desc.
Cant.
Descripción
Because of its extreme ruggedness and high accuracy, the PX1006 is Typically Built-to-order
  
PX1006L1-015DV
Consultar Ventas  
Disponible en: 
 
 
15 psid Wet/Dry differential pressure transducer with mV/V output and integral connector
  
PX1006L1-025DV
Consultar Ventas  
Disponible en: 
 
 
25 psid Wet/Dry differential pressure transducer with mV/V output and integral connector
  
PX1006L1-050DV
Consultar Ventas  
Disponible en: 
 
 
50 psid Wet/Dry differential pressure transducer with mV/V output and integral connector
  
PX1006L1-100DV
Consultar Ventas  
Disponible en: 
 
 
100 psid Wet/Dry differential pressure transducer with mV/V output and integral connector
  
PX1006L1-500DV
Consultar Ventas  
Disponible en: 
 
 
500 psid Wet/Dry differential pressure transducer with mV/V output and integral connector
  
PX1006L1-1KDV
Consultar Ventas  
Disponible en: 
 
 
1000 psid Wet/Dry differential pressure transducer with mV/V output and integral connector
  
PX1006L1-1.5KDV
Consultar Ventas  
Disponible en: 
 
 
1500 psid Wet/Dry differential pressure transducer with mV/V output and integral connector
  
PX1006L1-2KDV
Consultar Ventas  
Disponible en: 
 
 
2000 psid Wet/Dry differential pressure transducer with mV/V output and integral connector
  
PX1006L1-2.5KDV
Consultar Ventas  
Disponible en: 
 
 
2500 psid Wet/Dry differential pressure transducer with mV/V output and integral connector
  
PX1006L1-5KDV
Consultar Ventas  
Disponible en: 
 
 
5000 psid Wet/Dry differential pressure transducer with mV/V output and integral connector
Accessories
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloPT06F10-6S
PT06F10-6S
MXN1,215.00
Disponible en: 11 Semanas
 
Mating connector for PX1006 (sold separately)
Todas las cantidades que se muestran en MXN
Nota: Metric Ranges Available - Consult Engineering
Ejemplo de pedido: (1) PT06F10-6S mating connector (sold separately), MXN1,215.00 
We noticed you are from the US. Visit your local site for regional offers and live support.