New PX409 USBH Product Release With Upgraded High-Speed Software!
OMEGA is excited to announce the release of a major software update for our PX409 USB transducers! The fresh look and added features offer even more value and flexibility to your OMEGA® transducer purchase. Download your free copy today! Charting Window – The addition of a charting window allows you to see your data graphed in real time. The Y axis is configurable to allow simultaneous graphing of multiple engineering units. You can output the image of your data to a png file.
Channels Window - Display data from all of your sensors simultaneously. Each channel has configurable user alarms, three data filters, tare, resettable low/high indication, and sample rates ranging from 30 minutes to 1000Hz.
Logging Window – A new xls filetype output option presents preformatted data for readability. In addition, Live Statistics are displayed, including the sensor information, the start/stop time, the number of samples taken, the current reading, and the High/Low readings. With the logging window, you can capture your data for later analysis.
The PX409 High Speed USBH Series connects directly
to your computer. Free software makes data logging
and charting your readings a simple task. Also included
are .NET drivers and a command set for
command line access. The micro-machined silicon
design are ideal for pressure or level applications
in laboratory, test platforms, or bio/pharmaceutical
applications as well as industrial applications that
require a rugged, high accuracy transducer. The
micro-machined silicon sensor provides a very stable
transducer with exceptional high accuracy of ±0.08%
and a broad compensated range of -29 to 85°C
(-20 to 185°F). The modular construction allows for fast
delivery of most configurations and fittings.
SPECIFICATIONS Accuracy: 0.08% BSL (linearity, hysteresis and repeatability combined) Resolution: Up to 5.5 significant figures Zero Balance: ±0.5% full scale typical ±1% maximum (±1% typical, ±2% maximum for 2.5 psi and below) Span Setting: ±0.5% full scale typical ±1% maximum (±1% typical, ±2% maximum for 2.5 psi and below). Calibrated in vertical direction with fitting down Temperature Compensation (Over Compensated Range): Span: Range > 5 psi: ±0.5% Range ≤5 psi: ±1.0% Zero: Range > 5 psi: ±0.5% Range ≤ 5 psi: ±1.0% Minimum Isolation:
100 MΩ @ 50 Vdc case to sensor
2 MΩ @ 50 Vdc case to output terminations Pressure Cycles: 1 million, minimum Long Term Stability (1-Year): ±0.1% full scale typical A to D Conversion: 24-bit Shock: 50 g, 11 mS half sine, vertical and horizontal axis Vibration: 5-2000-5 Hz, 30 minute cycle, Curve L, Mil-Spec 810 figure 514-2-2, vertical and horizontal axis Bandwidth: DC to 1000 updates per second typical (±3%) Power Consumption: 0.35 W typical CE Compliant: Meets industrial emissions and immunity EN61326 Environmental Protection: IP65 Secondary Containment Gage/Vacuum/Compound Pressure: 10 inH2O to 5 psi: to 1000 psi 15 to 1000 psi: to 3000 psi 1500 to 5000 psi: to 10,000 psi Absolute/Barometric Pressure: 5 to 1000 psi: to 6000 psi 1500 to 5000 psi: to 10,000 psi Overpressure Gage/Vacuum/Compound Pressure 10 inH2O: 10 times span 1 psi: 6 times span 2.5 psi to 1000 psi: 4 times span 1500 psi yo 5000 psi: 7250 psi maximum Absolute/Barometric Pressure: 5 psia: 6 times span 15 psia to 1000 psia: 4 times span 1500 psia to 5000 psia: 7250 psia maximum Wetted Parts: 316L stainless steel Weight: 200 g (7 oz) Operating Temperature Range: -40 to 85°C (-40 to 185°F) Compensated Temperature: Ranges >5 psi: -29 to 85°C (-20 to 185°F) Ranges ≤5 psi: -17 to 85°C (0 to 185°F)
Ordenar Por Número de Parte
Todas las cantidades que se muestran en MXN Nota: Comes complete with 5-point NIST traceable calibration certificate, downloadable digital readout, logging software, .NET drivers and command set.
Generador de Número de Parte
Construya su Número de Parte Abajo
Opciónes de Descripción:
(1)
Pressure Range (PSI) seleccionar de: -10W para 10"H2O -001 para 0-1 psi -2.5 para 0-2.5 psi -005 para 0-5 psi -015 para 0-15 psi -030 para 0-30 psi -050 para 0-50 psi -075 para 0-75 psi -100 para 0-100 psi -150 para 0-150 psi -250 para 0-250 psi -500 para 0-500 psi -750 para 0-750 psi -1.0K para 0-1000 psi -1.5K para 0-1500 psi -2.5K para 0-2500 psi -3.5K para 0-3500 psi -5.0K para 0-5000 psi
-16 para 16 to 32 inHg (Barometric only) -26 para 26 to 32 inHg (Barometric only) -32 para 0 to 32 inHg (Barometric only)
(2)
Type seleccionar de: G para Gage A para Absolute (15 to 5000 psia) CG para Compound Gage (10W to 15 psi only) V para Vacuum (Negitive gage) B para Barometric Pressure DWU para Wet/Wet Unidirectional Differential WDU para Wet/Dry Unidirectional Differential
(3)
Output seleccionar de: USBH para High Speed USB
Nota: Todas las combinaciones pueden no ser válidas, revise la hoja de especificaciones para números de parte válidos