En México: 01800-953-00-93
Correo de Ventas:ventas@mx.omega.com

RTD PT100 Sensor Probe with Lead Wires (5-Pack)

RTD-2 (Class B) 5-Pack Series

RTD PT100 Sensor Probe with Lead Wires | RTD-2  (Class B) 5-Pack Series

RTD PT100 Sensor Probe with Lead Wires

MXN4,670.00 RTD-2-F3105-36-T-B

  • RTD Sensor Probe In Stock for Immediate Delivery
  • Class “B” RTD element = ±0.12 Ohms at 0ºC) Accuracy
  • Sold in Economical 5 Packs and OEM Bulk Packs
  • Simple, Flexible Sensing Option for a Wide Variety of Measurement Applications
  • Stripped Leads Termination. Connector terminations also available.
Sondas, elementos y asambleas RTD (PT100) - Ver Productos Relacionados

Descripción

RTD PT100 probe sensors have Class B elements with attached lead wire in a convenient 5 pack. These OEM RTD sensors are supplied with attached lead wires for added flexibility in many replacement probe or OEM RTD sensor applications. The size of the potted junction between the lead wire and element is kept as small as possible. Note: These elements are not intended for direct immersion into liquids. Configurations below reflect 36" lead wire, Style-2 (3 Wire). 2 Wire or 4 Wire RTD probe subassemblies with long leads can also be shipped quickly.
Hacer Pedido(Especifique el Número de Modelo)

Lo que han comprado otras personas: Cuando vea este icono, haga clic sobre él para abrir la lista de productos que otras personas han comprado al adquirir este modelo

Número de parte/Desc.
Cant.
Descripción
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloRTD-2-F3102-36-T-B
RTD-2-F3102-36-T-B
MXN4,930.00
Disponible en: Disponible
 
F3102 (4 x 5 mm) RTD element, PFA insulated lead wire, epoxy transistion.
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloRTD-2-F3105-36-T-B
RTD-2-F3105-36-T-B
MXN4,670.00
Disponible en: 3 Semanas
 
F3105 (2 x 2 mm) RTD element, PFA insulated lead wire, epoxy transistion.
  
RTD-2-F3102-36-G-B
MXN4,835.00
Disponible en: 3 Semanas
 
F3105 (4 x 5 mm) RTD element, Fiberglass insulated lead wire, ceramic transistion.
  
RTD-2-F3105-36-G-B
MXN4,930.00
Disponible en: 3 Semanas
 
F3105 (2 x 2 mm) RTD element, Fiberglass insulated lead wire, ceramic transistion.
  
RTD-2-1PT100KN2528-36-T-B
MXN9,275.00
Disponible en: 3 Semanas
 
1PT100KN2528 RTD element, PFA insulated lead wire, epoxy transistion.
  
RTD-2-1PT100K2515-36-T-B
MXN9,460.00
Disponible en: Disponible
 
1PT100K2515 RTD element, PFA insulated lead wire, epoxy transistion.
Most Popular Accessories
  
CN1501-RTD
MXN11,940.00
Disponible en: 4 Semanas
 
1/8 DIN ON-Off Temperature or Process Controller
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloCN1A-RTD
CN1A-RTD
MXN8,245.00
Disponible en: Disponible
 
1/16 DIN On-Off LCD Temperature Controller
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloOM-CP-QUADRTD
OM-CP-QUADRTD
Consultar Ventas  
Disponible en: 
 
 
4-Channel Temperature Data Logger
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloHH804U
HH804U
MXN6,510.00
Disponible en: Disponible
 
Precision Handheld Thermometer
  
DP460-RTD
Consultar Ventas  
Disponible en: 
 
 
Economical Temperature Meter
Todas las cantidades que se muestran en MXN
Nota: Above models shown as three-wire configurations, for two-wire construction change the “-2” in the model number to “-1”; for four-wire construction change “-2” to “-3”. To order sensors with bare wires and connections for use to 600ºC (1112ºF), replace “-T” or “-G” in model number with “-B”. For longer lead wires, change “-36” in the model number to length desired and add $1/ft per sensor. Terminations available: “-LUG” copper lugs, add $4.50 per sensor; for “-OTP” and “-MTP” connectors add $7 per sensor.
(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
Ejemplo de pedido: (1) RTD-2-1PT100K2515-36-T-B 1PT100K2515 element with 1 m (40, MXN9,460.00

Generador de Número de Parte

Construya su Número de Parte Abajo
Opciónes de Descripción:


(1) Wires Configuration seleccionar de:
2 para Standard 3 wires configuration
1 para 2 Wires Configuration
3 para 4 Wires Configuration

(2) RTD Element Type seleccionar de:
F3105 para Thin film
F3102 para Thin film
1PT100K2515 para Wire-wound elements
1PT100KN2528 para Wire-wound elements.

(3) Insulation Types seleccionar de:
T para PFA insulated cable attached (epoxy potted)
G para Fiberglass-insulated cable attached (ceramic potting)
B para Bares Wires (No insulation)

(4) Additional Options seleccionar de:
Nada (dejar el campo en blanco) para None
-LUG para Spade style terminal lugs standard termination in stripped leads
-OTP para Connectors (3-wire only)
-MTP para Miniature connector
Nota: Todas las combinaciones pueden no ser válidas, revise la hoja de especificaciones para números de parte válidos