En México: 01800-953-00-93
Correo de Ventas:ventas@mx.omega.com

Heavy Weight Oil Flanged Immersion Heaters

TMO Series

Oil Heaters | TMO Series

Oil Heaters

Ver Todas los Modelos Abajo

  • Rugged Steel Sheath
  • Low Watt Density 6 1/2" W/in2
  • 1.2 to 8.4 kW
  • 3 & 5 Inch, 150 Ib. Steel Flange
Calentadores de inmersión - Ver Productos Relacionados

Descripción

FEATURES
Rugged construction, Sturdy 0.475" diameter elements welded to steel flanges provide superior rigidity and strength. Heavy duty jumper straps and terminal posts assure permanent tightness of connection’s carrying capacity.

High conductivity elements — Filled with highest purity blends of magnesium oxide refractory (MgO) compacted to a rock hard density to insure maximum thermal conductivity, maximum electrical resistance, and assure long element life.

Heavy coil construction– Watt density on the heating coil is designed for low watt density operation by increasing the coil diameter and length to give maximum coil surface temperature, providing longer coil life.

APPLICATIONS
Heating heavy, viscous oils reduces their viscosity, permitting better pumpability for transfer operations. Lowering the viscosity allows increased system flows for any given horsepower. Transfer system designs can employ smaller motor and drive components ensuring optimum system economy.

Preheating permits use of less expensive fuel oils, allows easier pumping and provides better atomization, increasing combustion efficiency.

CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warning.



kW Dim. B
in. (cm)
Wt.4
Ib. (kg)
E1 General Purpose Enclosure1 Dim.N3
in. (cm)
3 Inch-150 Lb. Steel Flange, 3 Steel Sheath Elements — 6.5 W/in2
1.225 3/16 (64)17 (8)TMO-3012L/240V/3P1 (3)
1.6533 1/16 (84)18 (8)TMO-3016L/240V/3P1 (3)
240 9/16 (103)20 (9)TMO-3021L/**/3P1 (3)
2.548 1/16 (122)21 (10)TMO-3024L/240V/3P1 (3)
5 Inch-150 Lb. Steel Flange, 6 Steel Sheath Elements — 6.5 W/in2
1.518 1/16 (46)27 (12)TMO-6015L/240V/3P1 (3)
1.819 13/16 (50)30 (14)TMO-6018L/240V/3P1 (3)
2.425 3/16 (64)32 (15)TMO-6024L/240V/3P1 (3)
3.333 1/16 (84)33 (15)TMO-6033L/**/3P1 (3)
4.240 9/16 (103)34 (15)TMO-6042L/**/3P1 (3)
548 1/16 (122)37 (17)TMO-6049L/**/3P1 (3)
5.452 1/16 (132)38 (17)TMO-6054L/**/3P1 (3)
658 3/8 (148)40 (18)TMO-6060L/**/3P1 (3)
6.965 1/16 (165)42 (19)TMO-6069L/**/3P1 (3)
7.268 5/8 (174)43 (20)TMO-6072L/**/3P1 (3)
8.478 1/16 (198)46 (21)TMO-6084L/**/3P1 (3)
/** Designate voltage, i.e. insert 240V for 240 Vac or 480V for 480 Vac.
Note: Larger flange sizes and kW ratings and power supplies are available. contact OMEGALUX.
1 Heaters with General Purpose and Moisture Resistant Enclosures are UL Listed and CSA Certified.
2 Heaters with Explosion Resistant Enclosures are CSA NRTL/C certified and are not intended for use in hazardous areas.
3 E1 enclosure “N” designates conduit size, E2/E3/E4 enclosures “N” designates NPT threat size.
4 Weights:
    A. For Wt. of 3" flange with E2 enclosure, add 3 lbs. to Wt. of E1 enclosure.
    B. For Wt. of 5" flange with E3 or E4 enclosure, add 7 lbs. to Wt of E1 enclosure.
Hacer Pedido(Especifique el Número de Modelo)
Número de parte/Desc.
Cant.
Descripción
Example part numbers are shown below. For additional configurations see the Part Number Builder below this table.
TMO-6084L/480V/3P
Consultar Ventas  
Disponible en: 
 
 
Heater, 8.4 kW, 480 V, 6 steel sheath elements, 3 phase power
Todas las cantidades que se muestran en MXN

Generador de Número de Parte

Construya su Número de Parte Abajo
Opciónes de Descripción:


(1) Number of Steel Sheath Elements seleccionar de:
3 para 3 Steel Sheath Elements
6 para 6 Steel Sheath Elements

(2) Wattage seleccionar de:
012 para 1.2 kW
016 para 1.65 kW
021 para 2 kW
024 para 2.5 kW
015 para 1.5 kW
018 para 1.8 kW
024 para 2.4 kW
033 para 3.3 kW
042 para 4.2 kW
049 para 5 kW
054 para 5.4 kW
060 para 6 kW
069 para 6.9 kW
072 para 7.2 kW
084 para 8.4 kW

(3) Voltage seleccionar de:
240V para 240 V
480V para 480 V
Nota: Todas las combinaciones pueden no ser válidas, revise la hoja de especificaciones para números de parte válidos