En México: 01800-953-00-93
Correo de Ventas:ventas@mx.omega.com

Miniature Head Mount Temperature Transmitters with RFID Communications

TX400-Series

Head Mount Temperature Transmitters | TX400-Series

Head Mount Temperature Transmitters

MXN1,720.00 TX401

2 años de garantía CE
  • UL Approved
  • High Accuracy & 16-Bit Conversion
  • TX401 Accepts Pt100, Pt1000 or Ni100 RTD Inputs
  • TX402 Accepts Pt100 or Ni100 RTD Inputs and Types J/K/T/E/R/S/B/N Thermocouples
  • User Configurable via TX400-RFID (NFC) Programmer with PC Software or Free Download Google App - "Direct Link" By Phone
  • Transmitters Have Non-Volatile Memory (Circular Buffer) for Data-Logging with User-Selectable Sampling Time
Instrumentos de medición y control de proceso - Ver Productos Relacionados

Descripción

The TX401 and TX402 head mount temperature transmitters transform a temperature signal acquired from a Pt100, Pt1000 (TX401 only) or Ni100 RTD sensor or from a thermocouple (TX402 only) into a linearized 2-wire loop-powered 4 to 20 mA output. The characteristics of these converters ensure high precision on the reading scale with 16-bit conversion. The 4 to 20 mA output can be scaled based on the desired temperature input range.

The programming procedure uses an RFID (NFC) mode with the dedicated TX400-RFID programmer that allows the user to make all calibrations and settings quickly and without the need to power and connect up the transmitter. Simply connect the TX400-RFID programmer to the USB port of your PC, start the RF Programmer configuration software and place the transmitter on top of the TX400-RFID programmer to establish communications.

An additional programming tool is the Omega Brand Google App - "Direct Link" relying on RFID/NFC connectivity and allowing straightforward programming without wirings by Android devices.

These temperature transmitters are also provided with a data logging function for the input signal. Transmitters have a non-volatile memory (circular buffer) for data-logging with user-selectable sampling time. The user selects the sampling time (1 to 3600 seconds) and then each time the 4 to 20 mA loop powers the device, the input value is stored to nonvolatile memory.

Using the TX400-RFID programmer along with the RF Programmer configuration software (software is a free download from OMEGA) the user can:
     Completely configure the transmitter including scaling the 4 to 20 mA output to desired temperature input range
     Implement field calibration to compensate for gain and offset errors
     Download logged data to PC for visualization and printing

Specifications
RTD Input Types and Ranges:
    TX401, TX402: Pt100 (a = 0.00385), 2, 3, or 4-wire connection: TX401: -200 to 800°C (-328 to 1472°F), TX402: -200 to 600°C (-328 to 1112°F)
    TX401 Only: Pt1000 (a = 0.00385), 2-wire connection; -200 to 800°C (-328 to 1472°F)
    TX401, TX402: Ni100 (a = 0.00618), 2, 3, or 4-wire connection: TX401: -50 to 170°C (-58 to 338°F), TX402: -60 to 180°C (-76 to 356°F)
Thermocouple Input Types (TX402 Only): J/K/T/E/R/S/B/N/mV
Output Resolution: 1 µA
Over-Range Output: FS + 5°C
Under-Range Output: FS - 5°C
Output Error (Failure): Selectable: TX401: between 21.5 or 3.8 mA, TX402: between 21 or 3.8 mA
Current Output Protection: 30 mA approx
Rejection: 50 to 60 Hz
Maximum Transmission Error: 0.1% FS or 0.2°C whichever is greater
Sampling Time: 300 msec
Response Time (10 to 90%): 600 msec
Non-Volatile Memory (Circular Buffer) for Data Logging:
    TX401: 3966 Data Points
    TX402: 2546 Data Points
Cable Resistance: 20Ω max
Temperature Coefficient: <100 ppm
Power: 2-wire loop powered; operating range 6 to 32 Vdc
Isolation:
    TX401: Non-isolated
    TX402: galvanic, 1 KVac input/output
Operating Environment: -40 to 85°C (-40 to 185°F), 30 to 90% RH (non condensing)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Mounting: DIN/B head
Enclosure Material: Nylon (PA66)
Enclosure Rating: NEMA 1 (IP20) according to CE, EN 61000-6-4, EN 61000-6-2
Programming: Wireless with RFID technology (NFC)
Software: Windows® XP/7/8 (32-bit and 64-bit), Windows 10 (64-bit)
Connection: Screw terminals
Weight: 30 g (1.05 oz) approx
Dimensions: 23 H x 45 mm dia (0.9 x 1.77")
Hacer Pedido(Especifique el Número de Modelo)

Lo que han comprado otras personas: Cuando vea este icono, haga clic sobre él para abrir la lista de productos que otras personas han comprado al adquirir este modelo

Número de parte/Desc.
Cant.
Descripción
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloTX401
TX401
MXN1,720.00
Disponible en: Disponible
 
RTD input head mount RFID temperature transmitter
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloTX402
TX402
MXN2,860.00
Disponible en: Disponible
 
Thermocouple/RTD input head mount RFID temperature transmitter
Haga clic para abrir la lista de productos que otras personas han comprado al adquirir este modeloTX400-RFID
TX400-RFID
MXN6,435.00
Disponible en: Disponible
 
RFID programmer
Todas las cantidades que se muestran en MXN
Nota:
TX400-RFID programmer is supplied with complete user’s guide and USB interface cable. User’s guide for the TX401 and TX402 transmitters can be downloaded from OMEGA. RF programmer PC configuration software is a free download from OMEGA.

Google App "Direct Link" can be free downloaded from Google Store or get a copy from our software link here.


Ejemplo de pedido: (1) TX400-RFID RFID programmer, MXN6,435.00  plus (1) TX402 Thermocouple//RTD input head mount RFID temperature transmitter, MXN2,860.00, MXN6,435.00 + 2,860.00 = MXN9,295.00

Manuales de Productos:

Descarga Head Mount RTD Input Transmitter RFID
Descarga Head Mount TC/RTD Input Transmitter RFID
Descarga RF Programmer for TX400, TXDIN400 Series

Software:

Descarga RF Programmer Software for TX400 and TXDIN400
Descarga Omega Brand NFC Apps – Direct Link
We noticed you are from the US. Visit your local site for regional offers and live support.