En México: 01800-953-00-93
Correo de Ventas:mxventas@dwyeromega.com

Vapor and Gas Actuated Thermometers, Panel & Surface Mount - Discontinued

VA and GA Series

Vapor and Gas Actuated Thermometers | VA and GA Series

Vapor and Gas Actuated Thermometers

Ver Todas los Modelos Abajo

  • Accuracy ±1 Scale Division or 1% Scale for Gas
  • Brass Movement with Precision Gearing
  • White Dial with Black Graduations
  • Phosphor Bronze Bourdon Tube
Termómetros de bombilla de vidrio y DialTemp - Ver Productos Relacionados

Descripción

This item is no longer available. Please contact Customer Service for further assistance.

Remote vapor- and gas-actuated thermometers are manufactured to the highest standards for a wide range of uses and can be fitted into almost any temperatureindicating application. These instruments are ideal for remote reading, such as panel installations, with capillary lengths of 1 to 100'. Vapor, or more precisely vaporized liquid, thermometers will give excellent readings, provided the temperature being measured is above or below ambient temperature. Vapor instruments also have progressive graduations and are best read in the upper 2/3 of the dial range. Many ranges are available between -40 to 232°C (-40 to 450°F), and care should be taken to select a range that will locate the operating temperatures within the upper 2/3 of the dial range.

OMEGA gas-actuated thermometers combine advanced gas coil technology with a state-of-the-art gas absorbent (Class IV) thermal system, producing a superior temperature measurement instrument that can be fitted to a wide variety of applications. Gas-actuated thermometers have an advantage over vapor-actuated thermometers in that they are more accurate over the full range. They also operate at higher and lower ranges than vapor-actuated thermometers.

The linear dial on all OMEGA gas thermometers provides a consistent 1% accuracy across the full span of each range. This, combined with over 20 Fahrenheit and dual ranges, from -196 to 649°C (-320 to 1200°F), provides complete coverage of all normal temperature requirements.

SPECIFICATIONS
Dial Sizes: 2", 2½", 3½", 4½"
Dial: Aluminum with white finish and black markings
Pointer: Furnished standard adjustable
Movement: Brass with precision gearing
Bourdon Tube: Vapor-phosphor bronze
Gas: Nitrogen in nispan coil
Accuracy:
    Vapor: ±1 scale division
    Gas: ±1% of scale
Process Connection: Plain bulb, ½NPT union; or thermowell
Note: thermowells must be used whenever the bulb would be exposed to pressure, fluid velocity, or corrosive media.
Window: Polycarbonate STD; glass available on all models
Bulb: Stainless steel or copper; bulb O.D. 3/8" on plain bulbs, 7/16" with threads. Bulb lengths from 2½" to 7 7/8" depending on capillary length.
Capillary: Copper, copper with bronze braid armor; stainless steel with stainless steel armor; capillary lengths 1 to 100' (standard length, 5')
Hacer Pedido(Especifique el Número de Modelo)
Número de parte/Desc.
Cant.
Descripción
GA-25FR-FN-E-30-L2
Consultar Ventas  
Disponible en: 
 
 
Gas Actuated Thermometer
GA-35RB-FL-E-05-J1
Consultar Ventas  
Disponible en: 
 
 
Gas Actuated Thermometer
VA-35RB-60-D-3-M2
Consultar Ventas  
Disponible en: 
 
 
Vapor Actuated Thermometer
VA-45RR-20-E-5-J1
Consultar Ventas  
Disponible en: 
 
 
Vapor Actuated Thermometer

Ordenar Por Número de Parte

Número de parte
Cant.
Número de parte
Cant.


Todas las cantidades que se muestran en MXN

Generador de Número de Parte

Construya su Número de Parte Abajo
Opciónes de Descripción:


(1) Style seleccionar de:
VA para Vapor Actuated Thermometer
GA para Gas Actuated Thermometer

(2) Case Style and Size seleccionar de:
20FR para Front Flange (Panel Mount) style.Dial 2 in. Case stainless steel. Connection location rear
25FR para Front Flange (Panel Mount) style. Dial 2 1/2 in. Case stainless steel. Connection location rear
35FR para Front Flange (Panel Mount) style. Dial 3 1/2 in. Case stainless steel. Connection location rear
45FR para Front Flange (Panel Mount) style. Dial 4 1/2 in. Case stainless steel. Connection location rear
45FL para Front Flange (Panel Mount) style. Dial 4 1/2 in. Case black aluminum (hinge ring type). Connection location lower rear
20UR para U-Clamp (Panel Mount) style. Dial 2 in. Case stainless steel. Connection location rear
25UR para U-Clamp (Panel Mount) style. Dial 2 1/2 in. Case stainless steel. Connection location rear
35UR para U-Clamp (Panel Mount) style. Dial 3 1/2 in. Case stainless steel. Connection location rear
20RR para Rear flange (Surface Mount) style. Dial 2 in. Case stainless steel. Connection location rear
35RR para Rear flange (Surface Mount) style. Dial 3 1/2 in. Case stainless steel. Connection location rear
35RB para Rear flange (Surface Mount) style. Dial 3 1/2 in. Case stainless steel. Connection location bottom
45RR para Rear flange (Surface Mount) style. Dial 4 1/2 in. Case stainless steel. Connection location rear
45RB para Rear flange (Surface Mount) style. Dial 4 1/2 in. Case stainless steel. Connection location bottom
45TB para Rear flange (Surface Mount) style. Dial 4 1/2 in. Case Phenolic. Connection location bottom (turret)

(3) Temperature Range (ranges 300°F or above for vapor-actuate and all gas-actuated models only offered with stainless steel systems.) seleccionar de:
20 para -40 to 60°F (VA Range only)
21 para -40 to 60°F (-40 to 15°C) (VA Range only)
30 para -40 to 110°F (VA Range only)
31 para -40 to 110°F (-40 to 40°C) (VA Range only)
32 para -20 to 120°F (VA Range only)
33 para -20 to 120°F (-30 to 50°C) (VA Range only)
72 para 0 to 180°F (VA Range only)
73 para 0 to 180°F (-20 to 80°C) (VA Range only)
49 para 0 to 150°F (VA Range only)
79 para 0 to 150°F (-15 to 65°C) VA Range only)
80 para 20 to 220°F (VA Range only)
81 para 20 to 220°F (0 to 105°C) (VA Range only)
50 para 40 to 240°F (VA Range only)
51 para 40 to 240°F (0 to 115°C) (VA Range only)
56 para 0 to 250°F (VA Range only)
57 para 0 to 250°F (-20 to 120°C) (VA Range only)
60 para 30 to 300°F (VA Range only)
61 para 30 to 300°F (0 to 150°C) (VA Range only)
68 para 100 to 350°F (VA Range only)
66 para 100 to 350°F (40 to 175°C) (VA Range only)
FB para -320 to 100°F (GA Range only)
DB para -320 to 100°F (-200 to 40°C) (GA Range only)
FE para -120 to 120°F (GA Range only)
DE para -120 to 120°F (-85 to 50°C) (GA Range only)
FG para -40 to 180°F (GA Range only)
DG para -40 to 180°F (-40 to 80°C) (GA Range only)
FH para 0 to 120°F (GA Range only)
DH para 0 to 120°F (-15 to 50°C) (GA Range only)
FJ para 60 to 120°F (GA Range only)
DJ para 60 to 120°F (15 to 50°C) (GA Range only)
FL para 20 to 240°F (GA Range only)
DL para 20 to 240°F (-5 to 110°C) (GA Range only)
FN para 0 to 300°F (GA Range only)
DN para 0 to 300°F (-10 to 150°C) (GA Range only)
FP para 50 to 550°F (GA Range only)
DP para 50 to 550°F (10 to 29°C) (GA Range only)
FR para 50 to 750°F (GA Range only)
DR para 50 to 750°F ( 0 to 400°C) (GA Range only)
FT para 400 to 1200°F (GA Range only)
DT para 400 to 1200°F (200 to 650°C) (GA Range only)
70 para 200 to 450°F (GA Range only)
71 para 200 to 450°F (100 to 230°C) (GA Range only)

(4) Capillary and Bulb seleccionar de:
A para Capillary and bulb material copper.
C para Capillary and bulb material copper. Capillary protection bronze braid
D para Capillary and bulb material 316 SS.
E para Capillary and bulb material 316 SS. Capillary protection SS armor

(5) Capillary Length (For custom length contact our sales team for pricing) seleccionar de:
05 para 5 Feet
10 para 10 Feet
25 para 25 Feet

(6) Process Connection seleccionar de:
J1 para Connection type none (plain bulb)
K2 para Connection type 1/2 NPT union. Material Brass
L2 para Connection type 1/2 NPT union. Material 316 SS
M2 para Connection type 1/2 NPT union jam nut and bendable extension. Material 316 SS
J2 para Connection type Jam nut only (required with thermowell). Material Brass
J3 para Connection type Jam nut only (required with thermowell). Material 316 SS

(7) Lens seleccionar de:
Nada (dejar el campo en blanco) para None
-Glass para Glass lens
-Poly para Polycarbonate Lens
Nota: Todas las combinaciones pueden no ser válidas, revise la hoja de especificaciones para números de parte válidos
We noticed you are from the US. Visit your local site for regional offers and live support.