Works with UWTC and UWRTD series Wireless Pt100 and Thermocouple Transmitters
Automatically Scans Up to 8 Transmitters
Ethernet interface with Embedded Web Server - Allows Realtime Data Monitoring and Recording on a PC using a standard Web Browser
2 Alarm Outputs: Solid State Relays (SSR’s), dc Pulse, Mechanical Relays, Analogue Voltage and Current
Descripción
wiSeries Wireless Monitoring
and Control System
The OMEGA wiSeries wireless monitoring
and control system features controllers and scanners
compatible with a large and growing number of
OMEGA™ wireless sensors:
UWTC: Wireless Thermocouple Transmitters; Type J, K, T, E, R, S, B, N, and C.
UWRTD: Wireless Pt100 Temperature Transmitters UWTC-NB9/UWRTD-NB9: Industrial Pt100 and Thermocouple Probes with In-Head Wireless Transmitters UWIR: Wireless Infrared Temperature Sensor & Transmitter
UWXL-TC and UWXL-RTD: Rugged Thermocouple and Pt100 Transmitters in Industrial Housings zSeries: Wireless Wall-Mount Temperature Transmitters with Integral Sensor.
The wiDR DIN-rail mount Controller can
monitor up to eight (8) wireless sensors.
The compact instrument connects directly to an
Ethernet network and the Internet and features
OMEGA's award-winning embedded Web Server. It is
easily configured and monitored with a Web browser
over the Ethernet network or the Internet.
Alternatively, the wiDR controller can instead be
connected to the USB port of a single computer with a
"USB Ethernet Adaptor" that are inexpensive and widely available.
MONITOR AND ALARM
The wiDR controller comes standard with a
choice of either two Form C relays, or two SSR's (solid
state relays) that can be used for control functions or
alarms. The wiDR controller can monitor alarm conditions
for any or all of the wireless sensors. For example, the
wiDR controller can be set up to trip an alarm if any one of
the sensors indicated it was above or below a pre-set
alarm point.
CONTROL LOCALLY AND MONITOR
OVER THE INTERNET
The OMEGA™ wiSeries wireless monitoring and
control system provides local control,
along with remote Web-based monitoring of
temperature from thermocouple, Pt100 and
semiconductor sensors.
The wireless sensors transmit up to 120m (without obstructions or interference)
to a wiDR series controller connected directly
to an Ethernet network and the Internet. The wireless
system complies with IEEE 802.15.4 operating at
2.4 GHz.
The OMEGA wiSeries system let's you monitor and
record measurements over an Ethernet network or the Internet
without any special software - just your Web Browser.
WIRELESS SENSORS
OMEGA offers a wide and growing selection of
wireless sensors for a variety of applications.
Depending on application, the wireless sensors run on either batteries or AC power.
The AC version comes with a universal AC Adaptor that
operates on any voltage worldwide from 100 to 240 Vac,
and includes a single lithium back-up battery.
Wireless sensors are available with external probes
appropriate for an almost unlimited variety of industrial
and commercial applications.
ETHERNET
The wiSeries controller is an
independent node on the network sending and
receiving data in standard TCP/IP packets. It is easily
configured from a Web Browser and can be password
protected. From within an Ethernet LAN or over the
Internet, the user simply types the IP address (such
as 192.168.1.200) or an easy to remember name
(such as "Oven 5" or "Engine Test Bay") and
the wiSeries controller serves a Web Page with the
current readings.
ALARM AND EMAIL
The wiSeries controller can trigger an alarm if variables go
above or below a set point that you determine. Your
alarm can be sent by email to a single user or to a
group distribution list, including text messages to
mobile phones and PDA's. The OMEGA
"Mail Notifier" software is a free and easy program for
this application.
The wiSeries
controllers
operate on any
AC voltage
worldwide from
100 to 240 Vac
and 50 to 60 Hz.
The controller
connects directly
to an Ethernet
Network or the Internet. Unlike an RS232 or USB
device, it does not require a host computer.
EMBEDDED WEBSERVER
The OMEGA wiSeries wireless sensor system is easy
to install, simple to operate, and features OMEGA's
award-winning iServer technology with an Embedded
Web Server that requires no special software.
CHARTS AND GRAPHS
The OMEGA wiDR system serves Active Web
Pages to display real time readings and charts of
temperature, humidity, and barometric pressure. You
can also log data in standard data formats for use in a
spreadsheet or data acquisition program such as Excel
or Visual Basic. OMEGA offers a free and easy to use
program for logging data to Excel.
The virtual chart viewed on the web page is a JAVA
Applet that records a chart over the LAN or Internet in
real time. With the OMEGA wiSeries system there is
no need to invest time and money learning a
proprietary software program to log or chart the data.
Chart scales are fully adjustable on the fly. For
example, the chart can display one minute, one hour,
one day, one week, one month or one year.
Temperature and humidity can be charted across the
full span (-40 to 125°C) or within
any narrow range such as (20 to 30°C).
OMEGA offers an OPC Server software (additional charge) that
makes it easy to integrate the wiSeries wireless sensor
system with many popular Data Acquisition and
Automation programs offered by Omega, Wonderware,
iConics, Intellution, Rockwell Automation, and National
Instruments, among others.
QUALITY AND TECHNOLOGY
Designed and manufactured in the USA, the
innovative OMEGA™ wiSeries of controllers features an extended 1 year warranty
at no extra charge.
SPECIFICATIONS Input Types: UWTC: Wireless Thermocouple Transmitters; Type J, K, T, E, R, S, B, N, and C. UWRTD: Wireless Pt100 Temperature Transmitters UWTC-NB9/UWRTD-NB9: Industrial Pt100 and Thermocouple Probes with In-Head Wireless Transmitters UWIR: Wireless Infrared Temperature Sensor & Transmitter UWXL-TC and UWXL-RTD: Rugged Thermocouple and Pt100 Transmitters in Industrial Housings zSeries: Wireless Wall-Mount Temperature Transmitters with Integral Sensor.
Refer to individual wireless products for their specifications.
Control Output 1 & 2 Relay: 250 Vac or 30 Vdc @ 3A (resistive load); configurable for ON/OFF Output 1: SPDT type, can be configured as Alarm 1 output Output 2: SPDT type, can be configured as Alarm 2 output SSR: 20 to 265 Vac @ 0.05 to 0.5A (resistive load); continuous DC Pulse: Non-Isolated; 10 Vdc @ 20 mA
Alarm 1 & 2 (programmable) Type: Same as Output 1 and 2 Operation: High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations Analogue Output (programmable): Non-Isolated, Retransmission 0 to 10Vdc or 0 to 20mA, 500Ω max (Output 1 only). Accuracy is ± 1% of FS when following conditions are satisfied. 1) Input is not scaled below 1% of Input FS. 2) Analogue Out is not scaled below 3% of Output FS.
Network and Communications Ethernet: Standards Compliance IEEE 802.3 10Base-T Supported Protocols: TCP/IP, ARP LED Indicators: Network Activity, Network Link, Diagnostics, Receive & Power Management: Device configuration and monitoring through embedded WebServer Embedded WEB Server: Serves WEB pages ( JAVAâ„¢ Applets) containing real-time data and live updated charts within definable time intervals. Software:OMEGA Enterprise Gateway
Wireless Communication Standard: IEEE 802.15.4 Frequency: 2.4 GHz (2410MHz), 12 Channels (for wiDRxx-U)
2.4 GHz (2410MHz), 16 Channels (for wiDRxx-zT) Network Topology: Star Topology Range: UWTC-1, UWRTD-1: up to 60 m (200 ft) without obstructions or interference. UWTC-2, UWRTD-2, UWIR-2-NEMA: up to 120 m (400 ft) without obstructions or interference. UWXL: up to 120 m (400 ft) without obstructions or interference. zED-*: up to 91 m (300 ft) without obstructions or interference. zED-*-P, zED-*-LCD, zED-*-TC, zED-*-CCELL: up to 91 m (300 ft) without obstructions or interference.
General Connection: Screw terminals wiDR Dimensions: 93 H x 39 W x 125 mm D Operating Temp: 0 to 55°C, 90% RH non-condensing Line Voltage/Power: 90 - 240 Vac ±10%, 50 - 400 Hz*, 110 - 375 Vdc, equivalent voltage, 4W
*No CE compliance above 60 Hz Low Voltage/Power Option: 24 Vac**, 20 - 36 Vdc, 3W.
External power source must meet Safety Agency Approvals
** Units can be powered safely with 24Vac power, but no certification for CE are claimed
Note: A complete wireless system requires at least: one (1) End Device (zED-T* or UWTC-*) and one (1) Coordinator/Receiver (wiDRxx-zT or wiDRxx-U).
Todas las cantidades que se muestran en MXN Nota: Other outputs options are available, please contact our Sales Department.
Manuales de Productos:
Descarga
wiDRxx-zT Series - Wireless DIN Rail Monitor and Controller
Descarga
wiDR-U Series - Wireless DIN Rail Monitor and Controller