Opciónes de Descripción:
(1)
Electrical Termination seleccionar de:09 para Cable with flying leads 2 m (6'')
09C para Cable with 1/2 NPT conduit connector (no trim pots not demountable)
09CP para Cable with 1/2 NPT conduit connector and side accessible trim pots
09CW para Submersible cable with 1/2 NPT conduit connector (no trim pots not demountable) 3 m (10'')
09CWP para Submersible cable with 1/2 NPT conduit connector and side accessible trim pots (not demountable) 3 m (10'')
19 para Mini-Din connector
29 para Bendix twist-lock connector
39 para DIN connector (mating connector not included)
49 para Glass to metal sealed solder pins
59 para M12 connector
(2)
Range seleccionar de:025HG para 0 to 25 mb (Gage Pressure Only)
070HG para 0 to 70 mb (Gage Pressure Only)
170HG para 0 to 170 mb (Gage Pressure Only)
350HG para 0 to 350 mb (Gage Pressure Only)
001BG para 0 to 1 bar (Gage Pressure Only)
002BG para 0 to 2 (Gage Pressure Only)
3.5BG para 0 to 3.5 (Gage Pressure Only)
007BG para 0 to 7 (Gage Pressure Only)
010BG para 0 to 10 (Gage Pressure Only)
17.5BG para 0 to 17.5 (Gage Pressure Only)
035BG para 0 to 35 (Gage Pressure Only)
050BG para 0 to 50 (Gage Pressure Only)
070BG para 0 to 70 (Gage Pressure Only)
100BG para 0 to 100 (Gage Pressure Only)
175BG para 0 to 175 (Gage Pressure Only)
245BG para 0 to 245 (Gage Pressure Only)
7BSG para 0 to 7 bar (Sealed Gage Only)
10BSG para 0 to 10 (Sealed Gage Only)
17.5BSG para 0 to 17.5 (Sealed Gage Only)
35BSG para 0 to 35 (Sealed Gage Only)
50BSG para 0 to 50 (Sealed Gage Only)
70BSG para 0 to 70 (Sealed Gage Only)
100BSG para 0 to 100 (Sealed Gage Only)
175BSG para 0 to 175 (Sealed Gage Only)
245BSG para 0 to 245 (Sealed Gage Only)
350HA para 0 to 350 mb (Absolute Pressure Only)
001BA para 0 to 1 bar (Absolute Pressure Only)
002BA para 0 to 2 (Absolute Pressure Only)
3.5BA para 0 to 3.5 (Absolute Pressure Only)
007BA para 0 to 7 (Absolute Pressure Only)
010BA para 0 to 10 (Absolute Pressure Only)
17.5BA para 0 to 17.5 (Absolute Pressure Only)
035BA para 0 to 35 (Absolute Pressure Only)
050BA para 0 to 50 (Absolute Pressure Only)
070BA para 0 to 70 (Absolute Pressure Only)
100BA para 0 to 100 (Absolute Pressure Only)
175BA para 0 to 175 (Absolute Pressure Only)
245BA para 0 to 245 (Absolute Pressure Only)
025HCGB para ±25 mbar (Compound Gage Range Only)
070HCGB para ±70 mbar (Compound Gage Range Only)
170HCGB para ±170 mbar (Compound Gage Range Only)
350HCGB para ±350 mbar (Compound Gage Range Only)
001BCGB para ±1 bar (Compound Gage Range Only)
025HV para 0 to -25 mbar (Vacuum Range Only)
070HV para 0 to -70 mbar (Vacuum Range Only)
170HV para 0 to -170 mbar (Vacuum Range Only)
350HV para 0 to -350 mbar (Vacuum Range Only)
001BV para 0 to -1 bar (Vacuum Range Only)
1100HB para 0 to 1100 hPa (Barometric Range Absolute Pressure Only)
550HB para 550 to 1100 hPa (Barometric Range Absolute Pressure Only)
880HB para 880 to 1100 hPa (Barometric Range Absolute Pressure Only)
Nota: Todas las combinaciones pueden no ser válidas, revise la hoja de especificaciones para números de parte válidos