Multi-Parameter Input Transmitter For pH/ORP
|
Click for larger image. |
|
|
|
|
|
|
The DPU91 transmitter provides a
single channel interface for many
different parameters including flow,
pH/ORP, conductivity/resistivity,
salinity and temperature. The
DPU91-BC transmitter has the
added capability of supporting the
batch module for batching control.
The extra-large (3.90 x 3.90")
autosensing backlit display can
be viewed at 4 to 5 times the
distance over traditional transmitters.
The highly illuminated display and
large characters reduce the risk of
misreading or misinterpreting the
displayed values. The display shows
separate lines for units, main and
secondary measurements as well
as a “dial-style” digital bar graph.
The DPU91 is offered in both panel
or field-mount versions. Both
configurations can run on 12 to
32 Vdc power (24 Vdc nominal)and have 4 to 20 mA outputs.
Designed for complete flexibility,
plug-in modules allow the unit to
easily adapt to meet changing
customer needs. Optional modules
include relay, direct conductivity/
resistivity, batch and a PC
communications configuration tool.
The unit can be used with default
values for quick and easy
programming or can be customized
with labeling, adjustable minimum
and maximum dial settings, and unit
and decimal measurement choices.
Specifications
General
Input Channels: 1
Input Types: Digital serial ASCII, TTL level, 9600 bps
Frequency Range: 0.5 to 1500 Hz
Accuracy: 0.5% of reading (display)
Measurement Types: Flow, pH/ORP, conductivity/resistivity, salinity, pressure, temperature or batch
Enclosure and Display
Case Material: PBT
Window: Shatter-resistant glass
Keypad: 4 buttons, injection-molded silicone rubber seal
Display: Backlit, 7 and 14-segment
Update Rate: 1 second
LCD Contrast: 5 settings
Indicators: “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator
Enclosure: ¼ DIN, NEMA 4X/IP65
Mounting Panel: ¼ DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket (included)
Field Mounts: Specified to OMEGA™ field mount junction boxes
Weight: 0.63 kg (1.38 lb) DPU91-pH/ORP Series
Display Ranges
For flow version visit omega.com/dpu91_flow For conductivity/resistivity version visit omega.com/dpu91_conductivity
pH: 0.00 to 15.00
pH Temperature: -99 to 350°C (-146 to 662°F)
ORP: -1999 to 1999.9 mV
Temperature: -99 to 350°C (-146 to 662°F)
Environmental
Ambient Operating Temperature:
Backlit LCD: -10 to 70°C (14 to 158°F)
Storage Temperature: -15 to 70°C (5 to 158°F)
Relative Humidity: 0 to 100% condensing for field mount; 0 to 95% noncondensing for panel mount
Maximum Altitude: 4000 m (13,123')
Electrical Requirements
Power to Sensors:
Voltage: 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected
Terminal Blocks: Pluggable screw type 14 AWG maximum wire gauge
Input Power
DC: 10.8 to 35.2 Vdc, regulated
Current Output: 4 to 20 mA (10.8 to 35.2 VDC, 30 mA max)
DPU91 without Relay Module: 200 mA @ 10.8 to 35.2 Vdc
DPU91 with Relay Module: 300 mA @ 10.8 to 35.2 Vdc
Open Collector: 1
Overvoltage Protection: 48 V transient protection device current limiting for circuit protection and reverse-voltage protection
Relay Specifications (DPU91-R optional relay module)
Dry-Contact Relays: 2
Type: SPDT Form C
Maximum Current Rating: 5 A resistive 50 mA DC
Maximum Voltage Rating: 30 Vdc or 250 Vac
Hysteresis Adjustable: Absolute in engineering units (EUs)
Latch Reset: In test screen only
Delay: 9999.9 seconds (maximum)
Test Mode: Set on/off
Cycle Time: 99999 seconds (maximum)
Maximum Pulse Rate: 400 pulses/minute
Proportional Pulse: 400 pulses/minute
Volumetric Pulse Width: 0.1 to 3200 s
Pulse Width Modulation: 0.1 to 320 s
Input Types
Digital or AC Frequency: pH/ORP input via the digital output from the PHTX-2750 pH/ORP sensor electronics For flow models visit omega.com/ dpu91_flow
Raw Conductivity/Resistivity: Input directly from compatible conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850 For conductivity/resistivity models visit omega.com/dpu91_conductivity
Input Specifications
Digital Serial: ACSII, TTL level, 9600 bps
Frequency Input:
Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency
Span: 0.5 Hz to 1500 Hz @ TTL level input
Accuracy: ± 0.5% or reading maximum error @ 25°C (°77F)
Resolution: 1 µS
Repeatability: ±0.2% of reading
|
| |
|
|
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with operator’s manual.
Electrodes and mounting kits sold separately.
|
|
|
|
|
| |
Related Links -
Manual, Related Products
|
Product Manual |
Download pH/ORP Electrodes |
Download pH/ORP Preamplifier |
Download Installation Kits and Hardware Accessories |
Download pH/ORP Sensor Electronics |
Download Transmitter |
Download Optional Modules for Batch Controller |
Related Products |
|
|
|
|
DPU91_Conductivity: |
Multi-Parameter Input Transmitter For Conductivity, Resistivity and Salinity |
|
|
|
|
|
|