TEL: 01-800-099-0420 (In México) | 001-203-359-7577 (Outside México)
 Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
Home >> Automation Products >> Process Measurement... >> Signal Conditioners... >> DRSL-DC1

Isolated DIN Rail Repeater

DRSL-DC1   
1 year warranty CE RoHS
 
Isolated DIN Rail Repeater
DRSL-DC1:Isolated DIN Rail Repeater
Click for larger image.
   
USD$6,785.00  DRSL-DC1
Isolation and 1:1 Conversion of Current Signals
1 Current Input—1 Current Output
Slimline Housing—Only 6 mm (0.24") Wide
Fast Response Time <7 ms
High Accuracy, <0.05% of Span
Easy-to-Use—No Setup Needed

View related products - Process Measurement and Control Instruments

Click to scroll below to order See Specs PDF Manuals Related Items View a printer friendly page

The DRSL-DC1 isolated repeater provides a competitive choice in terms of both price and technology for galvanic isolation of current signals to SCADA systems or PLC equipment. The unit provides isolation and 1:1 conversion of standard current signals.

The unit offers isolation between input, output and supply. Provides surge suppression and protects control systems from transients and noise. The DRSL-DC1 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Measurement ranges are factory calibrated. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).

SPECIFICATIONS
CURRENT INPUT
Measurement Range: 0 to 20.5 mA
Functional Range: 0 to 23 mA
Input Voltage Drop: <1.5 Vdc

CURRENT OUTPUT
Signal Range: 0 to 20.5 mA (span)
Load: 23 mA/600 Ω max
Load Stability: ≤0.01% of span/ 100 Ω (span = 0 to 20 mA)
Current Limit: ≤28 mA

GENERAL
Supply Voltage (via Power Rail or Connectors): 16.8 to 31.2 Vdc
Power Consumption: 0.8 W max
Internal Consumption: 0.4 W typical/0.65 W max
Isolation: Input/output/supply
Isolation Voltage (Test): 2.5 kVac
Isolation Voltage (Working): 300 Vac
MTBF: >284 years, according to IEC 61709 (SN29500)
Signal/Noise Ratio: >60 dB
Response Time (0 to 90%, 100 to 10%): <7 ms
Accuracy: <±0.05 % of span
Temperature Coefficient: <±0.01% of span/°C
EMC Immunity Influence: <±0.5% of span
Extended EMC Immunity NAMUR NE 21, A Criterion, Burst: <±1% of span

ENVIRONMENTAL
Operating Temperature: -25 to 70°C (-13 to 158°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Calibration Temperature: 20 to 28°C (68 to 82°F)
Relative Humidity: 0 to 95% RH non-condensing
Protection Degree: IP20
Installation Area: Pollution degree 2 and measurement/overvoltage category II

MECHANICAL
Dimensions: 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5")
Weight: 70 g (0.15 lb) approx
DIN Rail Type: DIN EN 60715 - 35 mm
Wire Size: 0.13 x 2.5 mm2/AWG 26 to 12 stranded wire
Screw Terminal Torque: 0.5 Nm


To Order (Specify Model Number)    
expand list What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.
 Part Number   Availability   Price   Description RoHS   Qty.
    DRSL-DC1 In Stock   6,785.00    Isolated repeater for current signals RoHS compliant
 Accessories
Click to expand/minimize a list of what others bought with the DRSL-PWR-RAIL  DRSL-PWR-RAIL In Stock   5,275.00    Power rail (with cover and two end covers, one right hand and one left hand), 1 m (3.3') length RoHS compliant
Click to expand/minimize a list of what others bought with the DRSL-PCU  DRSL-PCU In Stock   3,625.00    Power connector unit, 24 Vdc/2.5 A output to power rail RoHS compliant
    DRSL-MOD-STOP 2 Weeks   240.00    Module stop (screwed onto power rail to support and hold mounted devices) RoHS compliant
All dollar amounts on this site are shown in US currency.

 Ordering Example: (1) DRSL-DC1 Isolated repeater for current signals, USD$6,785.00,  plus (1) DRSL-MOD-STOP Module stop (screwed onto power rail to support and hold mounted devices), USD$240.00,  plus (1) DRSL-PCU Power connector unit, 24 Vdc/2.5 A output to power rail, USD$3,625.00,  plus (1) DRSL-PWR-RAIL Power rail (with cover and two end covers, one right hand and one left hand), 1 m (3.3') length, USD$5,275.00, USD$6,785.00 + 240.00 + 3,625.00 + 5,275.00 = USD$15,925.00

 Related Links - Manual, Related Products
 Product Manual
   Download Installation Guide for Signal Conditioners
   Download DIN Rail Isolators and Signal Conditioners
 Related Products
DRSL-DC2 DRSL-DC2:
Isolated DIN Rail Signal Conditioner
DRSL-DC3 DRSL-DC3:
Isolated DIN Rail Signal Conditioner
DRSL-DC4 DRSL-DC4:
Bipolar Isolated DIN Rail Signal Conditioner for Process Signals
DRSL-SP1 DRSL-SP1:
Isolated DIN Rail Repeater/Splitter for Current Signals
DRSL-SP2 DRSL-SP2:
Isolated DIN Rail Signal Conditioner/Splitter for Process Signals
DRSL-SP3 DRSL-SP3:
Bipolar Isolated DIN Rail Signal Conditioner/Splitter for Process Signals
DRSL-LPI_Series DRSL-LPI_Series:
DIN Rail Input Loop-Powered Isolators
DRSL-LPO_Series DRSL-LPO_Series:
DIN Rail 2-Wire Transmitter Isolators
DRSL-TC_Series DRSL-TC_Series:
Thermocouple Input DIN Rail Signal Conditioners
DRSL-RTD_Series DRSL-RTD_Series:
RTD Input DIN Rail Signal Conditioners
DRSL-RTD-LP DRSL-RTD-LP:
RTD Input Non-Isolated DIN Rail Loop-Powered Signal Conditioner
DRSL-TEMP DRSL-TEMP:
Isolated DIN Rail Loop-Powered Temperature Signal Conditioner
DRSL-U DRSL-U:
Isolated Universal Input DIN Rail Signal Conditioner
   

   Back to topBack to top




MMV | 6 | 020