TEL: 01-800-099-0420 (In México) | 001-203-359-7577 (Outside México)
 Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation

Clamp-On Ultrasonic Energy Flow Meter - Discontinued

FDT-40E Series   
1 year warranty CE
 
Clamp-On Ultrasonic Energy Flowmeter
FDT-40E Series:Clamp-On Ultrasonic Energy Flow Meter - Discontinued
Click for larger image.
   
Bi-Directional Flow/Energy Measurement
Rugged, Aluminum Enclosure
Rate and Total Backlit Display
4 to 20 mA and Dual Alarm Outputs
USB Programming Port
RS485 MODBUS® Network Connection
Click to scroll below to order See Specs PDF Manuals View a printer friendly page

Discontinued, no replacement.

.
FDT-40E Series ultrasonic flow and energy meters clamp on to the outside of pipes and do not come in contact with the internal liquid. The technology has inherent advantages over alternate devices including: low-cost installation, no pressure head loss, no moving parts to maintain or replace, no fluid compatibility issue, and a large, bi-directional measuring range that ensures reliable readings even at very low and high flow rates. FDT-40E Series is available in a variety of configurations that permit the user to select a meter with features suitable to meet particular application requirements.

Specifications
System
Liquid Types: Most clean liquids or liquids containing small amounts of suspended solids or gas bubbles
Velocity Range: Bi-directional to greater than 40 FPS (12 MPS)
Flow Accuracy:
    Larger Than 50 mm (2"): ±1% of reading or ±0.01 FPS (0.003 MPS), whichever is greater
    25 to 50 mm (1 to 2"): ±1% of reading or ±0.04 FPS (0.012 MPS), whichever is greater
    19 mm (¾") and Smaller: ±1% of full scale
Temperature Accuracy:
    Absolute: 0.25°C (0.45°F)
    Difference: 0.1°C (0.18°F)
Energy Temperature Range: 0 to 100°C (32 to 212°F)
Sensitivity Flow: 0.001 FPS (0.0003 MPS)
Temperature: 0.025°C (0.05°F)
Repeatability: 0.5% of reading Transmitter
Power Requirements (AC): 95 to 264 Vac 47 to 63 Hz @ 17 VA maximum standard, 20 to 28 Vac 47 to 63 Hz @ 0.35 A maximum (“-24VAC” models), 10 to 28 Vdc @ 5 W maximum (“-VDC” models)
Protection: Auto resettable fuse, reverse polarity and transient suppression
Display: Two line LCD, LED backlit; top row 18 mm (0.7") height, 7-segment; bottom row 9 mm (0.35") height, 14-segment
Icons: RUN, PROGRAM, RELAY1, RELAY2
Flow Rate Indication: 8-digit positive, 7-digit negative maximum; auto decimal, lead zero blanking
Flow Totalizer: 8-digit positive, 7-digit negative maximum (re-set via keypad press, software, network command or momentary contact closure
Enclosure NEMA 4 (IP65) Construction: Powder-coated aluminum, polycarbonate, stainless steel, polyurethane, nickel-plated steel mounting brackets
Size (Electronic Enclosure Only): 152 W x 112 H x 56 mm D (6.0 x 4.4 x 2.2")
Conduit Holes: (2) ½ NPT female (1) ¾ NPT female
Temperature: -40 to 85°C (-40 to 185°F)
RTD: Platinum 385, 1000O, 3-wire
Configuration: Via optional keypad or PC running software (Note: not all configuration parameters are available from the keypad – i.e. flow and temperature calibration and advanced filter settings)
Engineering Units Flow Meter: Feet, gallons, cubic feet, million gallons, barrels (liquid and oil), acre-feet, lbs, meters, cubic meters, liters, million liters, kg
Engineering Units Energy Meter: BTU, MBTU, MMBTU, Tons
Inputs/Outputs USB 2.0: For connection of a PC running configuration utility
    RS485: MODBUS RTU command set
    4 to 20 mA: 12-bit, internal power, can span negative to positive flow/energy rates
Transducers
Construction
    Standard (FDT-41 thru 46): NEMA 6 (IP67), PVC, PEI, Nylon cord grip, PVC cable jacket
    Temperature: -40 to 60°C (-40 to 140°F)
    FDT-41 thru 46 with “-HT” option, FDT-47 and FDT-48: NEMA 6 (IP67), CPVC, PEI, Nylon cord grip, PVC cable jacket
    Temperature: -40 to 90°C (-40 to 194°F)
    FDT-47 “-HT”: NEMA 6 (IP67), PTFE, polyimide, Nickel-plated brass cord grip, PFA cable jacket
    Temperature: -40 to 176°C (-40 to 350°F)
Frequency:
    FDT-41 thru 46: 2 MHz
    FDT-47: 1 MHz
    FDT-48: 500 KHz
Cables: RG59 coaxial, 75 Ω or twin axial, 78 Ω (optional armored conduit)
Cable Length: Standard 6 m (20') [300 m (990') maximum in 3 m (10') increments; submersible conduit limited to 30 m (100') for transducers]
Software Utilities Utilized to configure, calibrate and troubleshoot flowmeters. Connection via USB A/B cable; software is compatible with Windows 2000, Windows XP, Windows Vista® and Windows® 7
RS485 Network All FDT-40 meters come equipped with RS485 drivers and utilize a MODBUS RTU command set (data can be returned in single-precision, doubleprecision, integer or floating point values). Up to 126 units products can be run on a single daisy-chain network and be individually queried for flow rate, positive flow accumulator, negative flow accumulator and signal strength. Flow accumulators can be cleared at discrete addresses or globally. The RS485 network is also compatible with direct to Excel, application.


To Order (Specify Model Number)    
expand list What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.
 
Most Popular Models Highlighted!
 Part Number   Availability   Price   Description    Qty.
    FDT-40E    Consult sales   Energy flowmeter display 95 to 264 Vac, temperature range 0 to 100°C (32 to 212°F)  
    FDT-40E-VDC    Consult sales   Energy flowmeter display 10 to 28 Vdc, temperature range 0 to 100°C (32 to 212°F)  
    FDT-40E-24VAC 3 Weeks   137,080.00    Energy flowmeter display 24 Vac, temperature range 0 to 100°C (32 to 212°F)  
    FDT-40E-HT    Consult sales   Energy flowmeter display 95 to 264 Vac, temperature range -40 to 177°C (-40 to 350°F)  
    FDT-40E-VDC-HT 3 Weeks   131,890.00    Energy flowmeter display 10 to 28 Vdc, temperature range -40 to 177°C (-40 to 350°F)  
    FDT-40E-24VAC-HT 3 Weeks   137,080.00    Energy flowmeter display 24 Vac, temperature range -40 to 177°C (-40 to 350°F)  
 Accessory Remote Transducers (Display Sold Separately)
 Remote Transducers for ANSI Pipe (Display Sold Separately)
    FDT-41-ANSI    Consult sales   Transducer for 1/2" ANSI pipe  
    FDT-42-ANSI In Stock   22,265.00    Transducer for 3/4" ANSI pipe  
    FDT-43-ANSI    Consult sales   Transducer for 1" ANSI pipe  
    FDT-44-ANSI    Consult sales   Transducer for 1 1/4" ANSI pipe  
    FDT-45-ANSI Consult Sales   24,160.00    Transducer for 1 1/2" ANSI pipe  
    FDT-46-ANSI Consult Sales   25,885.00    Transducer for 2" ANSI pipe  
 Remote Transducers for Copper Pipe (Display Sold Separately)
    FDT-41-CP    Consult sales   Transducer for 1/2" Copper pipe  
    FDT-42-CP In Stock   22,265.00    Transducer for 3/4" Copper pipe  
    FDT-43-CP    Consult sales   Transducer for 1" Copper pipe  
    FDT-44-CP    Consult sales   Transducer for 1 1/4" Copper pipe  
    FDT-45-CP    Consult sales   Transducer for 1 1/2" Copper pipe  
    FDT-46-CP    Consult sales   Transducer for 2" Copper pipe  
 Remote Transducers for Tubing (Display Sold Separately)
    FDT-41-TUBE    Consult sales   Transducer for 1/2" tubing  
    FDT-42-TUBE    Consult sales   Transducer for 3/4" tubing  
    FDT-43-TUBE    Consult sales   Transducer for 1" tubing  
    FDT-44-TUBE    Consult sales   Transducer for 1 1/4" tubing  
    FDT-45-TUBE    Consult sales   Transducer for 1 1/2" tubing  
    FDT-46-TUBE    Consult sales   Transducer for 2" tubing  
 Remote Transducers (Display Sold Separately)
Click to expand/minimize a list of what others bought with the FDT-47  FDT-47 In Stock   33,340.00    Transducer for 2 to 24" pipe  
    FDT-47-100FT 4 Weeks   42,650.00    Transducer for 2 to 24" pipe with 100 ft of cable  
    FDT-47-HT 6 Weeks   130,615.00    High temperature transducer for 2 to 24" pipe  
    FDT-47-HT-100FT 6 Weeks   139,890.00    High temperature transducer for 2 to 24" pipe with 100 ft of cable  
    FDT-48 6 Weeks   53,520.00    Transducer for pipes over 24"  
    FDT-48-100FT 6 Weeks   62,925.00    Transducer for pipe over 24" with 100 ft of cable  
 Accessories
    FDT-40-PC-CABLE 4 Weeks   2,435.00    Optional USB PC programming cable  
    FDT-40-CABLE GLAND In Stock   1,275.00    Optional cable gland  
    FDT-40-BHC 3 Weeks   3,375.00    Brad Harrison connector for the FDT-40 Series  
    FDT-40-RTDCONN 4 Weeks   3,540.00    RTD Pig Tail (connection adapter)  
    FDT-40-RTD1 4 Weeks   22,095.00    RTD kit, clamp-on, 130C, 1000Ω 6.1 m (20')  
    FDT-40-RTD2 In Stock   27,720.00    RTD kit, clamp-on, 200C, 1000Ω 6.1 m (20')  
    FDT-40-RTD3 4 Weeks   40,655.00    RTD kit, insertion, 3 x 1/4", 126C, 1000Ω Platinum RTD  
Click to expand/minimize a list of what others bought with the FDT-GREASE  FDT-GREASE In Stock   2,490.00    Replacement acoustic couplant 150 g (5.3 oz)  
    FDT-HT-GREASE In Stock   5,590.00    High temperature acoustic couplant 56 g (2 oz)  
Click to expand/minimize a list of what others bought with the FDT-NS-GREASE  FDT-NS-GREASE 4 Weeks   2,490.00    Non-silicone acoustic couplant 79 g (2.8 oz)  
All dollar amounts on this site are shown in US currency.

 Note: Comes complete with operator’s manual. Transducers come with mounting gel.

Transducers sold separately.


 Part Number Builder
(1) (2) (3) (4)   
F
F
D
D
T
T
-
-
-
-
Qty:

Option Descriptions
(1) Pipe and Tubing Sizes
  Select
41 for 1/2 Inch
42 for 3/4 Inch
43 for 1 Inch
44 for 1 1/4 Inch
45 for 1 1/2 Inch
46 for 2 Inch
47 for 2 to 24 Inch
48 for Pipes over 24 inch
(2) Pipe and Tubing Material
  Select
ANSI for ANSI pipe
CP for Copper pipe
TUBE for Plastic tubing
(3) High Temperature
  Select
Nothing(leave field blank) for None
-HT for High temp transducers
(4) Cable Length
  Select
Nothing(leave field blank) for Standard 6 m (20 feet)
-100FT for 30 m (100 feet)
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


   

   Back to topBack to top