Screw Gear Flow meter for High Viscosity Liquids
|
Click for larger image. |
|
|
|
|
|
|
FHG-1000 flow meters measure the flow rate based
on the screw pump principle. A pair of rotors fitted
precisely into the housing constitutes the measuring
element. An integrated gear and non-contact signal
pick-up system detects the rotations of the measuring
element and converts them to digital pulses. Together
with the housing walls, the rotor edges form closed
measuring chambers in which the fluid is transported
from the inlet to the outlet side. The fluid volume put
through within one main rotor rotation is the rotation
volume, which is divided by the sensing gear and
digitized, processed and output in the sensor module.
Sensor System Explanation
The non-contact pick-up system consists of two
GMR-bridges (sin/cos), which are located in a sensor
unit in cartridge design. It detects the movement of
the sensing gear and routes the sin/cos-signals to the
preamplifier electronics. The preamplifier electronics
digitize and amplify the sensor signals and multiply
them by a high-resolution interpolator using adjustable
settings. The square wave signals are bidirectional and
can be utilized by any evaluating instrument as well as
computers and PLC-controls. The resolution is
selectable in steps from factor 1 to 128. In case of an
1-channel evaluation, a separate directional signal is
available. An adjustable pulse filter can offset and
suppress negative flows (e.g. generated by
vibrations) while still in the device. The frequency of the
output signals is proportional to the flow (volume flow)
and depends on the respective flow meter size. The
frequency range is from 0 to 100 kHz. The preamplifier
is protected against reverse polarity and incorrect
connection. It is suitable for fluid temperatures of
-30 to 120°C (-22 to 248°F) and is mounted directly on
the flow meter.
Flow meter Selection
For the trouble-free, safe and reliable operation of the
flow meters, selecting the correct type and size is
critical. Because of the wide variety of applications
and flow meter designs, the technical data in the
specifications are of a general nature. Certain
properties of the devices depend on type, size,
and measurement range as well as the liquid to
be measured. Please contact the Omega Flow
Department for detailed information about the
appropriate flow meter for your particular application.
Electronics
A special sensor system detects any movement of the
pair of rotors or of the liquid column. For this purpose,
a precision gear connected to a shaft of the rotor pair
is scanned by a special magneto-resistive sensor. The
scanning sensor includes two GMR-bridges (sin/cos)
and is housed in a removable stainless steel cartridge
case together with a signal conditioning and amplifier
unit. The downstream electronics unit features a highresolution
sin/cos-interpolator, which is adjustable with
10 different resolution factors. Furthermore, a
programmable signal filter is available as well, which
can offset unwanted negative pulse sequences up to
an adjustable degree. In addition, a signal for a
separate direction detection, e.g. in case of a
1-channel evaluation, is provided by the electronics.
Optionally, this output can be used for the detection of
excess flows and temperatures.
Specifications
Frequency Range: 0 to 100 kHz, adjustable
Measurement Accuracy: ±0.5% of measured value with viscosity of > 21 cSt
Repeatability Accuracy: ±0.05% with same operating conditions
Materials
Gray Cast Iron Model: EN-GJS-400-15 (EN 1563)/16 Mn Cr 5
Stainless Steel Model: Stainless steel 1.4305/1.4112, others available upon request
Bearing Fluid: Dependent as anti-friction bearing or SSIC/ wolfram carbide friction bearing
Seal:
Standard: FPM
Optional: PTFE, NBR or EPDM
Fluid Temperature: -30 to 120°C (-22 to 248°F)
Viscosity Range: 1 to 1.000.000 cSt
Installation Position: Any
Supply Voltage: 10 to 28 Vdc
Current Consumption: 65 mA at 24 Vdc unloaded
Delay: < 8 µs
Protection Class: IP65
Power Supply
Supply Voltage: u = 10 to 28 Vdc; reverse pole protection
Current Consumption: I0 = 65 mA (at 24 Vdc); unloaded
Delay: tV = 8 µs maximum (between scanning and measured value)
Signal Outputs
Output Signal Shape: Quadrature signals (A, B with 90° phase shift)
Directional Output: Positive high (24V), negative low (0.8 to 1V)
Error Output: Active high (24V), inactive low (0.8 to 1V)
Maximum Output Frequency: 100 kHz
Signal Voltage Output: VSS = 9 to 27 Vdc (channel 1, channel 2, error/direction)
Signal Output: Current Iout = 300 mA maximum at 24 Vdc (channel 1, channel 2)
|
| |
|
|
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with operator’s manual.
|
|
|
|
|
| |
Related Links -
Related Products
|
Related Products |
|
DPF20: |
Panel Meter for Frequency, Rate, Total or Period Counter 6-Digit, ⅛ DIN Panel Mount |
|
|
|
OM-DAQXL Series: |
8 or 16 Channel Universal Input Touch Screen Data Loggers - Discontinued |
|
|
|
|
|
|