TEL: 01-800-099-0420 (In México) | 001-203-359-7577 (Outside México)
 Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
Home >> Flow and Level Produ... >> Electronic Mass Flow... >> Economical Mass Flow... >> FMA-2600 SERIES

Mass Flow Controllers with 20+ Gas Select Function

FMA-2600 SERIES   
1 year warranty CE RoHS
 
Mass Flow Controllers with 20+ Gas Select Function
FMA-2600  SERIES:Mass Flow Controllers with 20+ Gas Select Function
Click for larger image.
   
130+ Gas Calibrations, Including: He, O2 , Neon, N2O, N2, Air, Argon, CO, CO2, Methane, Ethane, Propane, Butane, Acetylene, Ethylene, H2
Pressure, Temperature, Volumetric & Mass Flow Simultaneously Displayed
Easy Operator Push Button Interface
NIST Traceability Standard
Full Scale Ranges from 0.5 SCCM to 3000 LPM
Response Time of 100 milliseconds Typical
Turndown Ratio of 100:1 Typical
Position Insensitive
Accuracy of ±1% Full Scale
RS232 Standard
No Warm Up Time

View related products - Electronic Mass Flow Meters & Controllers

Click to scroll below to order See Specs PDF Manuals Related Items View a printer friendly page

The FMA-2600A Series mass and volumetric flow controllers use the principle of differential pressure within a laminar flow field to determine and control mass flow rate. A laminar flow element (LFE) inside the meter forces the gas into laminar (streamlined) flow. Inside this region, the Poiseuille equation dictates that the volumetric flow rate be linearly related to the pressure drop. A differential pressure sensor is used to measure the pressure drop along a fixed distance of the LFE. This, along with the viscosity of the gas, is used to accurately determine the volumetric flow rate. Separate absolute temperature and pressure sensors are incorporated and correct the volumetric flow rate to a set of standard conditions. This standardized flow rate is commonly called the mass flow rate and is reported in units such as standard cubic feet per minute (SCFM) or standard liters per minute (SLM).

The controller uses a true proportional valve coupled to the flow body to control flow using the integral PID loop controller. Standard units include a 0 to 5 V output (4 to 20 mA optional) and RS232 communications. The gas-select feature and the setpoints can be adjusted from the front keypad or via RS232 communications. Volumetric flow, mass flow, absolute pressure, and temperature can all be viewed or recorded through the RS232 connection. It is also possible to multi-drop up to 26 units on the same serial connection to a distance of 46 m (150').


SPECIFICATIONS

Accuracy: ±(0.8% of reading + 0.2%FS)
Repeatability: ±0.2% FS
Turndown Ratio: 100:1
Control Response Time: 100 ms
Input Control Signal: 0 to 5 Vdc, RS232
Output Signal: 0 to 5 Vdc, RS232
Optional Input/Outputs: 4 to 20 mA, 0 to 10 Vdc
Operating Temperature: -10 to 50°C (14 to 122°F)
Zero Shift: 0.02%/ATM FS/°C
Span Shift: 0.02%/ATM FS/°C
Humidity Range: 0 to 100% RH, non-condensing
Excess Flow Rate: 2.4% FS
Wetted Materials: Small Valve: 303 & 302 Stainless Steel, FKM, Heat Cured Silicone Rubber, Glass Reinforced Polyphenylene Sulfide, Heat Cured Epoxy, Aluminum, Gold, Brass, 430FR Stainless Steel, Silicon, Glass. Large Valve: 303 & 302 Stainless Steel, FKM, Heat Cured Silicone Rubber, Glass Reinforced Polyphenylene Sulfide, Heat Cured Epoxy, Aluminum, Gold, 416 Stainless Steel, Silicon, Glass.
-LSS (Option):316LSS, 303SS, 430FRSS, Perfluoroelastomer standard, FKM, EPDM, Buna, Neoprene Maximum Pressure: Mass Flow Controllers: 145 psig
To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flowmeters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig Minimum Differential Pressure Required:
5 SLM and under: 5 psid; 10 to 250 SLM:
15 psid; 500 SLM: 5 psid; 1500 SLM: 10 psid
Supply Current: 0.250 A for 20 SLM and under; 0.75 A for 50 SLM and above (typical)
Supply Voltage: 12 to 30 Vdc for units
20 SLM and smaller; 24 to 30 Vdc for units
50 SLM and larger
Electrical Connections: 8-pin circular mini DIN


To Order (Specify Model Number)    
expand list What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.
 Part Number   Availability   Price   Description RoHS   Qty.
 Mass Flow Controllers
    FMA-2601A 9 Weeks   89,345.00    0.5 SCCM, 10 to 32 UNF Thread RoHS compliant
    FMA-2601A-I 9 Weeks   91,920.00    0.5 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output RoHS compliant
    FMA-2602A 9 Weeks   89,345.00    1 SCCM, 10 to 32 UNF Thread RoHS compliant
    FMA-2602A-I 9 Weeks   91,920.00    1 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output RoHS compliant
    FMA-2614A 3 Weeks   79,450.00    2 SCCM, 10 to 32 UNF Thread RoHS compliant
    FMA-2614A-I 3 Weeks   82,385.00    2 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output RoHS compliant
    FMA-2615A 3 Weeks   79,450.00    5 SCCM, 10 to 32 UNF Thread RoHS compliant
    FMA-2615A-I 3 Weeks   82,385.00    5 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output RoHS compliant
    FMA-2603A 3 Weeks   74,585.00    10 SCCM, 10 to 32 UNF Thread RoHS compliant
    FMA-2603A-I 3 Weeks   77,490.00    10 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output RoHS compliant
    FMA-2616A 3 Weeks   74,585.00    20 SCCM, 10 to 32 UNF Thread RoHS compliant
    FMA-2616A-I 3 Weeks   77,490.00    20 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output RoHS compliant
Click to expand/minimize a list of what others bought with the FMA-2604A  FMA-2604A 3 Weeks   83,920.00    50 SCCM, 10 to 32 UNF Thread RoHS compliant
    FMA-2604A-I 3 Weeks   92,085.00    50 SCCM, 10 to 32 UNF Thread, one 4 to 20 mA output RoHS compliant
    FMA-2617A 2 Weeks   64,200.00    100 SCCM, 1/8 FNPT connection RoHS compliant
    FMA-2617A-I 3 Weeks   67,010.00    100 SCCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2618A 3 Weeks   60,770.00    200 SCCM, 1/8 FNPT connection RoHS compliant
    FMA-2618A-I 3 Weeks   67,010.00    200 SCCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2619A 3 Weeks   64,200.00    500 SCCM, 1/8 FNPT connection RoHS compliant
    FMA-2619A-I 3 Weeks   67,010.00    500 SCCM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2620A 2 Weeks   64,200.00    1 SLM, 1/8 FNPT RoHS compliant
    FMA-2620A-I 3 Weeks   67,010.00    1 SLM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2605A 3 Weeks   64,200.00    2 SLM, 1/8 FNPT RoHS compliant
    FMA-2605A-I 3 Weeks   67,010.00    2 SLM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2606A 3 Weeks   60,770.00    5 SLM, 1/8 FNPT RoHS compliant
    FMA-2606A-I 3 Weeks   67,010.00    5 SLM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2607A 3 Weeks   64,200.00    10 SLM, 1/8 FNPT RoHS compliant
    FMA-2607A-I 3 Weeks   67,010.00    10 SLM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2608A 2 Weeks   70,600.00    20 SLM, 1/8 FNPT RoHS compliant
    FMA-2608A-I 3 Weeks   77,490.00    20 SLM, 1/8 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2609A In Stock   80,085.00    50 SLM, 1/4 FNPT RoHS compliant
    FMA-2609A-I 3 Weeks   87,480.00    50 SLM, 1/4 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2610A 3 Weeks   94,960.00    100 SLM, 1/4 FNPT RoHS compliant
    FMA-2610A-I 3 Weeks   98,095.00    100 SLM, 1/4 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2611A 9 Weeks   95,075.00    250 SLM, 1/2 FNPT RoHS compliant
    FMA-2611A-I 9 Weeks   101,230.00    250 SLM, 1/2 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2612A 9 Weeks   104,135.00    500 SLM, 3/4 FNPT RoHS compliant
    FMA-2612A-I 9 Weeks   106,520.00    500 SLM, 3/4 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2613A 9 Weeks   118,080.00    1000 SLM, 3/4 FNPT RoHS compliant
    FMA-2613A-I 9 Weeks   120,985.00    1000 SLM, 3/4 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2621A    Consult sales   1500 SLM, 3/4 FNPT RoHS compliant
    FMA-2621A-I    Consult sales   1500 SLM, 3/4 FNPT, one 4 to 20 mA output RoHS compliant
    FMA-2622A In Stock   152,105.00    2000 SLM, 3/4 FNPT RoHS compliancy undetermined
    FMA-2622A-I 9 Weeks   163,270.00    2000 SLM, 3/4 FNPT, one 4 to 20 mA output RoHS compliancy undetermined
    FMA-2623A 9 Weeks   181,720.00    3000 SLM, 1 1/4 FNPT RoHS compliancy undetermined
    FMA-2623A-I 9 Weeks   184,330.00    3000 SLM, 1 1/4 FNPT, one 4 to 20 mA output RoHS compliancy undetermined
 Volumetric Flow Controllers
    FVL-2602A    Consult sales   1 SCCM, 10-32 thread connection RoHS compliant
 Accessories
Click to expand/minimize a list of what others bought with the FMA1600-C1  FMA1600-C1 2 Weeks   1,865.00    Replacement 1.8M (6') 8 pin male Mini-DIN single ended, cable connector RoHS compliant
    FMA1600-C1-25 FT In Stock   3,575.00    7.62M (25') 8 pin male Mini-DIN single ended, cable connector RoHS compliant
    FMA1600-C2 2 Weeks   2,270.00    1.8M (6') 8 pin male Mini-DIN double ended, cable connector RoHS compliant
    FMA1600-C2-25 FT 2 Weeks   4,240.00    7.62M (25') 8 pin male Mini-DIN double ended, cable connector RoHS compliancy undetermined
Click to expand/minimize a list of what others bought with the FMA1600-C3  FMA1600-C3 In Stock   2,150.00    1.8M (6') 8 pin male Mini-DIN to DB9 female adapter RoHS compliant
    FMA1600-CRA 2 Weeks   2,270.00    1.8M (6') 8 pin male right angle Mini-DIN single ended cable connector RoHS compliancy undetermined
    FMA1600-MDB 3 Weeks   10,470.00    Multi Drop Box RoHS compliancy undetermined
Click to expand/minimize a list of what others bought with the FMA1600-PSU  FMA1600-PSU 2 Weeks   3,360.00    24 Vdc universal power supply RoHS compliancy undetermined
    FMA1600-E2    Consult sales   220VAC to 24VDC Power Supply for 50 LPM or greater RoHS compliant
 Tube Fitting Adapters for Threaded to 10/32
    FTNY-K210BN 4 Weeks   246.00    Nylon Body, TUBE ID 1/16" TO MALE 10-32UNF RoHS compliant
    FTPP-K210NP In Stock   246.00    Polypropylene Body, TUBE ID 1/16" TO MALE 10-32UNF RoHS compliant
    FTNY-K230BN 4 Weeks   246.00    Nylon Body, TUBE ID 1/8" TO MALE 10-32UNF RoHS compliant
    FTPP-K230NP    Consult sales   Polypropylene Body, TUBE ID 1/8" TO MALE 10-32UNF RoHS compliant
All dollar amounts on this site are shown in US currency.

 Note: Comes complete with 24 Vdc universal power supply, 1.8m (6') cable, 8-pin male Mini- DIN connector, operator's manual, and NIST certificate.

Standard units are calibrated to air @ 5 psig for 0 to 1 LPM, 15 psig for 2 to 10 LPM, 30 psig for 20 to 100 LPM, and 50 psig for 200 LPM and greater.

For custom calibrations, add "-(*)" to the model number, no additional cost. *Specify gas, and inlet/outlet or backpressure for custom calibrations.

Calibrations done at ambient (25C/77F) temperature only.

To replace the standard RS232 communications with RS485, add suffix "-RS485" to the model number, add $120 to the price.

Standard input is 0-5V, for optional 4-20 mA input add suffix "-IN" to the model number, no additional cost.

Standard output is scaled to the mass flow rate. For volumetric flow rate as standard output add suffix "-VOL" to the model number. For "-VOL" controllers the control loop is set to volumetric as standard.

Optional secondary output are scaled the same as the primary output scale. For an alternate output scale add suffix "-V2T" for voltage scaled for temperature, "-I2T" for current scaled for temperature, "-V2P" for voltage scaled for pressure or "-I2P" for current scaled for pressure, no additional cost.

For units scaled in SCFH, add suffix "-SCFH" to model number, no additional cost. Please specify the desired range in SCFH.

For totalizer option, add suffix "-TOT" to the model number, add $120 to the price. Please specify resolution.

This is a 6-digit counter. Examples: For totalizing in liters with 1/100 liter resolution, the max count would be 9999.99. For totalizing in liters with 1 liter resolution, the max count would be 999999.

For a Remote Display, add suffix "-RD-*FT" to the model number, add $210 to the price. Replace the * in the suffix with the required length in whole feet, the maximum length is 3.6576 m (12'). Please note the optimum distance in feet is between 2.7 to 3 m (9 to 10').

Ethernet/IP, DeviceNet, Modbus and Profibus communications are also available for an additional charge.


 Ordering Example: (1) FMA-2601A-I2 10-32 Thread Mass Gas Flow Controller with optional second channel output of 4-20mA, USD$94,665.00
 Part Number Builder
(1) (2) (3) (4) (5) (6) (7)   
F
F
M
M
A
A
-
-
2
2
6
6
A
A
Qty:

Option Descriptions
(1) Flow Range
  Select
01 for 0.5 SCCM
02 for 1 SCCM
14 for 2 SCCM
15 for 5 SCCM
03 for 10 SCCM
16 for 20 SCCM
04 for 50 SCCM
17 for 100 SCCM
18 for 200 SCCM
19 for 500 SCCM
20 for 1 SLM
05 for 2 SLM
06 for 5 SLM
07 for 10 SLM
08 for 20 SLM
09 for 50 SLM
10 for 100 SLM
11 for 250 SLM
12 for 500 SLM
13 for 1000 SLM
21 for 1500 SLM
22 for 2000 SLM
23 for 3000 SLM
(2) Output
  Select
Nothing(leave field blank) for None
-I for 4 to 20 mA output
-I2 for Two 4 to 20 mA outputs
-V2 for Two 0 to 5V Outputs
-I2T for Two 4 to 20 mA outputs second output for temperature
-V2T for Two 0 to 5V outputs second output for temperature
-I2P for Two 4 to 20 mA outputs second output for pressure
-V2P for Two 0 to 5V outputs second output for pressure
-VOL for Volumetric flow rate as standard output
(3) Integrated positive shut-off valve
  Select
Nothing(leave field blank) for Standard
-P for Integrated positive shut-off valve (only available on models up to 20 SLM)
(4) Input
  Select
Nothing(leave field blank) for 0 to 5V
-IN for 4 to 20 mA input
(5) RS485
  Select
Nothing(leave field blank) for RS232
-RS485 for RS485
(6) SCFH
  Select
Nothing(leave field blank) for Standard
-SCFH for Units scaled in SCFH
(7) Totalizer
  Select
Nothing(leave field blank) for Standard
-TOT for Totalizer
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


 Related Links - Related Products
 Related Products
FVL-1600 FMA-1600FVL & FMA-1600 Series FVL-1600 FMA-1600FVL & FMA-1600 Series:
Mass and Volumetric Flow Meters, 20+ Gas Selection
FT-HS, FT-ME, FT-MS, FT-BHU, FT-HT, FT-HE Series FT-HS, FT-ME, FT-MS, FT-BHU, FT-HT, FT-HE Series:
Tube Fittings
   

   Back to topBack to top