TEL: 01-800-099-0420 (In México) | 001-203-359-7577 (Outside México)
 Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
Home >> Flow and Level Produ... >> Electronic Mass Flow... >> Economical Mass Flow... >> FMA-4100/4300 Series

Programmable Mass Flow Meter and Totalizer

FMA-4100/4300 Series   
1 year warranty CE
 
PROGRAMMABLE MASS FLOW METER AND TOTALIZER
FMA-4100/4300 Series:Programmable Mass Flow Meter and Totalizer
Click for larger image.
   
USD$31,975.00  FMA-4102
23 Selectable Engineering Units (Including User Defined)
Programmable Totalizer
High and Low Gas Flow Alarms
Two Sets Programmable SPDT Relays with Latching Feature
Selectable Analog 0 to 5 Vdc or 4 to 20 mA Outputs
Internal Conversion Factors for Up to 32 Gases
Digital Interface RS-232 Standard
Automatic Sensor Zero Offset Adjustment (Via Digital Interface or Local Push Button)
Self-Diagnostic Tests
Display Units Include Adjustable Back Lighting

View related products - Electronic Mass Flow Meters & Controllers

Click to scroll below to order See Specs PDF Manuals View a printer friendly page

The FMA-4100/4300 Series flow rate can be displayed in 23 different volumetric flow or mass flow engineering units including a user specific selection. Flowmeters can be programmed remotely via RS232 or RS485 (optional). FMA-4100/4300 flowmeters support various functions including, programmable flow totalizer, high and low flow alarm, automatic zero adjustment, 2 relay outputs, jumper selectable 0 to 5 Vdc or 4 to 20 mA analog outputs, status LED diagnostic, storage of up to 10 different gas calibrations, internal or user-specific K-factors. Display models have local 2 lines x 16 characters LCD display with adjustable back light provides flow, total and diagnostic reading simultaneously. The digital RS232 or RS485 (optional) interface provides access to applicable internal data including, flow, CPU temperature, auto zero, totalizer and alarms settings, gas table, conversion factors and engineering units selection, dynamic response compensation and linearization table adjustment. The analog interface provides 0 to 5 Vdc or 4 to 20 mA (jumper selectable) outputs for flow reading.

The FMA-4100/4300 supports automatic sensor zero offset adjustment which can be activated locally via the maintenance push button or remotely via digital interface. The auto zero feature necessitates a condition of absolutely no flow through the meter during the adjustment process. Provisions are made to either start, read, or save the current auto zero value via digital commands. Digital totalizer commands include: set to zero, start at a preset flow, assign action to a preset value, start/stop totalizing and read. High and Low gas flow alarm limits can also be preprogrammed via digital interface. Alarm action can be assigned with preset delay interval (0 to 3600 seconds) to activate the contact closer (separate for high and low alarm). Latch mode control feature allows each relay to be latched on or follow the corresponding alarm status.

FMA-4100/4300 Transducers should not be used for monitoring Oxygen gas unless specifically clean and prepared for such application. See below for ordering instructions.

SPECIFICATIONS

Calibrations: Performed at standard conditions [101.4 kPa (14.7 psia) and 21.1°C (70°F)] unless otherwise requested or stated
Environmental (PER IEC 664): Installation Level II; Pollution Degree II
Flow Accuracy (Including Linearity): ±1% of FS at calibration temperature and pressure
Repeatability: ±0.15% of full scale
Flow Temperature Coefficient: 0.15% of full scale/°C or better
Flow Pressure Coefficient: 0.01% of full scale/psi (6.895 kPa) or better
Turndown Ratio: 50:1
Flow Response Time: 600 ms time constant; approximately 2 seconds to within ±2% of set flow rate for 25 to 100% of full scale flow
Max Gas Pressure: 3447 kPa gauge (500 psig)
Max Pressure Drop: Max Flow &#LE; 10 SLM: 1.28 kPa (0.18 psi)
                             Max Flow < 10 SLM: 27.58 kPa (4 psi)
Gas and Ambient Temperature: 5 to 50°C (41 to 122°F)
Relative Gas Humidity: Up to 70%
Leak Integrity: 1 x 10-9 SCCS He max to the outside environment
Attitude Sensitivity: Deviation of up to 1% from stated accuracy, after re-zeroing
Output Signals: Linear 0 to 5 Vdc (3000 Ω min load impedance); Linear 4 to 20 mA (500 Ω max loop resistance). Max noise 20 mV peak to peak (for 0 to 5 Vdc output)
Relay: SPDT (30 Vdc, 1A)
Transducer Input Power: 11 to 26 Vdc, 100 mV max peak to peak output noise
Power Consumption: +12 Vdc (200 mA max); +24 Vdc (100 mA max); Circuit board has built-in polarity reversal protection, 300 mA resettable fuse provide power input protection
Wetted Materials:
    Standard Aluminum Models: Anodized aluminum, brass, 316 stainless steel, FKM O-rings
    Optional Stainless Steel Models: 316 stainless steel, FKM O-rings
    Optional O-ring Materials: Buna, EPR (Ethylene Propylene), or perfluoroelastomer
Inlet and Outlet Connections:
    Model FMA-4100/4300: Standard 6.35 mm (1/4") compression fittings for up to 50 SLM.
                                       Standard 9.53mm (3/8") for models above 60 SLM
    Optional: 3.18 or 9.53 mm (1/8" or 3/8") compression fittings
Display (FMA-4300 Models): Local 2 lines x 16 characters LCD with adjustable backlight (2-lines of text)
Calibration Options: Standard is one 10-point NIST traceable calibration. Optional, up to 9 additional calibrations may be ordered at additional charge. Contact OMEGA for additional information
CE Compliance: EMC compliance with 89/336/EEC as amended
    Emission Standard: EN 55011:1991, Group 1
    Class A Immunity Standard:
    EN 55082-1:1992


To Order (Specify Model Number)    
expand list What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.
 Part Number   Availability   Price   Description    Qty.
 ALUMINUM BODY FLOW METERS WITHOUT DISPLAY
    FMA-4102 6 Weeks   31,975.00    0 to 5 SCCM range  
    FMA-4103 6 Weeks   30,310.00    0 to 10 SCCM range  
    FMA-4104 6 Weeks   30,310.00    0 to 20 SCCM range  
    FMA-4105 6 Weeks   30,310.00    0 to 50 SCCM range  
    FMA-4106 6 Weeks   30,310.00    0 to 100 SCCM range  
    FMA-4107 In Stock   30,310.00    0 to 200 SCCM range  
    FMA-4108 In Stock   31,975.00    0 to 500 SCCM range  
    FMA-4109 6 Weeks   30,310.00    0 to 1 SLM range  
    FMA-4110 6 Weeks   30,310.00    0 to 2 SLM range  
    FMA-4111 6 Weeks   30,310.00    0 to 5 SLM range  
    FMA-4112 6 Weeks   30,310.00    0 to 10 SLM range  
    FMA-4113 6 Weeks   36,575.00    0 to 20 SLM range  
    FMA-4114 2 Weeks   36,575.00    0 to 30 SLM range  
    FMA-4115 6 Weeks   36,575.00    0 to 40 SLM range  
    FMA-4116 In Stock   36,575.00    0 to 50 SLM range  
    FMA-4117 6 Weeks   46,010.00    0 to 60 SLM range  
    FMA-4118 6 Weeks   46,010.00    0 to 80 SLM range  
    FMA-4119 6 Weeks   47,210.00    0 to 100 SLM range  
 ALUMINUM BODY FLOW METERS WITH INTEGRAL BACKLIT DISPLAY
    FMA-4302 6 Weeks   33,440.00    0 to 5 SCCM range  
    FMA-4303 6 Weeks   33,440.00    0 to 10 SCCM range  
    FMA-4304 6 Weeks   33,440.00    0 to 20 SCCM range  
    FMA-4305 6 Weeks   33,440.00    0 to 50 SCCM range  
    FMA-4306 6 Weeks   33,440.00    0 to 100 SCCM range  
    FMA-4307 6 Weeks   33,440.00    0 to 200 SCCM range  
    FMA-4308 6 Weeks   33,440.00    0 to 500 SCCM range  
Click to expand/minimize a list of what others bought with the FMA-4309  FMA-4309 6 Weeks   33,440.00    0 to 1 SLM range  
    FMA-4310 6 Weeks   33,440.00    0 to 2 SLM range  
Click to expand/minimize a list of what others bought with the FMA-4311  FMA-4311 6 Weeks   33,440.00    0 to 5 SLM range  
Click to expand/minimize a list of what others bought with the FMA-4312  FMA-4312 In Stock   33,440.00    0 to 10 SLM range  
    FMA-4313 6 Weeks   39,775.00    0 to 20 SLM range  
    FMA-4314 6 Weeks   39,775.00    0 to 30 SLM range  
    FMA-4315 6 Weeks   39,775.00    0 to 40 SLM range  
    FMA-4316 In Stock   39,775.00    0 to 50 SLM range  
    FMA-4317 6 Weeks   47,775.00    0 to 60 SLM range  
    FMA-4318 In Stock   47,775.00    0 to 80 SLM range  
    FMA-4319 6 Weeks   46,075.00    0 to 100 SLM range  
 ACCESSORIES
    FMA-4000PS-AU 4 Weeks   3,795.00    Power supply 240 Vac, Australian plug  
    FMA-4000PS-EU In Stock   3,215.00    Power supply 230 Vac, European plug  
    FMA-4000PS-UK 4 Weeks   3,795.00    Power supply 240 Vac, U.K. plug  
Click to expand/minimize a list of what others bought with the FMA-4000PS-NA  FMA-4000PS-NA 4 Weeks   2,780.00    Power supply 110 Vac, North American plug  
    FMA-4000PS-AU-A 4 Weeks   5,325.00    Power supply 240 Vac, Australian plug with analog wires  
    FMA-4000PS-EU-A 4 Weeks   4,450.00    Power supply 230 Vac, European plug with analog wires  
    FMA-4000PS-UK-A 4 Weeks   5,325.00    Power supply 240 Vac, U.K. plug with analog wires  
    FMA-4000PS-NA-A 4 Weeks   4,055.00    Power supply 110 Vac, North American plug with analog wires  
Click to expand/minimize a list of what others bought with the FMA-4000C  FMA-4000C 4 Weeks   2,310.00    15-pin D connector, pre-wired for PC and power supply  

 Order custom models here
 
  Reset  

All dollar amounts on this site are shown in US currency.

 Note: Comes complete with software CD (operator's manual included on CD), 15-pin D pre-wired 1.8 m (6') cable, and NIST Certificate

Power supplies are sold separately. Power supplies also include cable.

Manual is on the software disc.

Calibrations done at ambient temperature (20°C/70°F) only.

For models with stainless steel body, add suffix "-ST" to model number, consult Flow Engineering for price.

To replace the RS232 communications with RS485, add suffix "-RS485" to model number, no additional cost.

For units with 1/8" compression fittings, add suffix "-1/8" to model number, no additional cost.

For units with 3/8" compression fittings, add suffix "-3/8" to model number, no additional cost.

For Oxygen cleaned units, add suffix "-O2CLEAN" to the model number; add $125 to price.
 Part Number Builder
(1) (2) (3) (4) (5)   
F
F
M
M
A
A
-
-
4
4
Qty:

Option Descriptions
(1) Display
  Select
1 for Without display
3 for With integral backlit display
(2) Range
  Select
02 for 0 to 5 SCCM
03 for 0 to 10 SCCM
04 for 0 to 20 SCCM
05 for 0 to 50 SCCM
06 for 0 to 100 SCCM
07 for 0 to 200 SCCM
08 for 0 to 500 SCCM
09 for 0 to 1 SLM
10 for 0 to 2 SLM
11 for 0 to 5 SLM
12 for 0 to 10 SLM
13 for 0 to 20 SLM
14 for 0 to 30 SLM
15 for 0 to 40 SLM
16 for 0 to 50 SLM
17 for 0 to 60 SLM
18 for 0 to 80 SLM
19 for 0 to 100 SLM
(3) Stainless Steel
  Select
Nothing(leave field blank) for None
ST for Stainless Steel
(4) Compression Fittings
  Select
Nothing(leave field blank) for None
-1/8 for 1/8 inch
-3/8 for 3/8 inch
(5) RS485
  Select
Nothing(leave field blank) for None
-RS485 for Communications with RS485
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


   

   Back to topBack to top