TEL: 01-800-099-0420 (In México) | 001-203-359-7577 (Outside México)
 Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
Home >> Temperature Products >> Wire: Thermocouple,... >> Extension Cables >> M12CFM-TC Series

M12 Cables with Field Mountable Connectors for Thermocouples

M12CFM-TC Series   
M12CFM-TC Series:M12 Cables with Field Mountable Connectors for Thermocouples
Click for larger image.
   
Straight and Right Angled M12 Field Mountable Connector Sensor End
PVC or PFA Insulated Thermocouple Compensated Cable Options Available in IEC and ANSI Color Codes
Optional Stainless Steel Braid and BX Hose is Available
Unlimited Variety of Configurations to Work With Your Instrumentation
Available in Single and Dual Element Configurations

View related products - Wire: Thermocouple, RTD, Thermistor and Hook-Up

Click to scroll below to order See Specs PDF Related Items View a printer friendly page

See our new M12 cables which include M12 thermocouple connector pins and socket materials, please see the M12CM Series

These thermocouple extension cables utilize field mountable M12 connectors (uncompensated) along with a wide variety of stranded thermocouple grade cables and the full line of Omega's popular thermocouple connectors to provide an unlimited selection of cable assemblies tailored to fit your specific application. When one of our standard M12C Over-Molded Thermocouple Cables simply won't provide the needed connection, these cables are just what is needed.

To configure your cable, simply determine the following information:

Cable Requirement:
The thermocouple extension cables include stranded thermocouple grade (or better) conductors with the standard insulations being PFA (TT) and PVC (PP). Note: The same insulation material is used for both the conductor insulation and over jacket. For dual element cables two individual cables are provided, one to each thermocouple set as shown in the table below.

These cables are the same as those used in our wide variety of thermocouple sensor products.

Sensor Connector:
Since our M12 enabled thermocouple sensors all utilize a plug style connector, you will most likely need a socket style connector to attach the cable to the sensor. These connectors are available in either straight (SFSR) or right angled (RFSR) configurations. Please note the following wiring information:

CABLE WIRING
M12 Connector
Pin Number
Type J ANSI Type J IEC Type K ANSI Type K IEC OSTW SMPW TC #
2 White Black Yellow Green + + 1 (+)
3 Red White Red White - - 1 (-)
4 White Black Yellow Green + + 2 (+)
1 Red WhiteRedWhite-- 2 (-)
Note: For single TC cables only pins 2 and 3 are connected as shown above. For dual T/C cables, one cable connects to pins 2 and 3 and the other cable connects to pins 1 and 4 as shown above.

Process Connection: The process connection can vary from stripped leads (FL), to another M12 style connector to one of the many styles of thermocouple connectors for which Omega is well known. Some of the most popular include straight M12 male connector (SMSR), right angled M12 male connector (RMSR), full size thermocouple connector (OSTW) and the miniature thermocouple connector (SMPW).

Cable Length: The final requirement is the length of your cable. Omega specifies the length of the cable in meters. Our standard selection of cables are provided in 3, 5, 10, 15 and 20 meter lengths, but you can specify a length longer or shorter then this. The length of the cable is simply listed on the end of the model number.

Omega has selected a number of these cables to be available as standard configurations, they are listed below. Also, there are additional special options such as external steel braid or armored hose that can be specified, please see the listing at the end of the product table.



To Order (Specify Model Number)    
 Part Number   Availability   Price   Description    Qty.
 PFA Insulated and Jacketed Cables
 M12CFM-TTJ24S-SFSR-FL-3 In Stock   1,340.00    Type J, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, ANSI Color Coded  
 M12CFM-TTK24S-SFSR-FL-3 4 Weeks   1,340.00    Type K, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, ANSI Color Coded  
 M12CFM-TTJI24S-SFSR-FL-3 4 Weeks   1,340.00    Type JI, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, IEC Color Coded  
 M12CFM-TTKI24S-SFSR-FL-3    Consult sales   Type KI, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, IEC Color Coded  
 M12CFM-TTJ24S-SFSR-FL-3-DUAL 4 Weeks   1,665.00    Dual Element Type J, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, ANSI Color Coded  
 M12CFM-TTK24S-SFSR-FL-3-DUAL In Stock   1,665.00    Dual Element Type K, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, ANSI Color Coded  
 M12CFM-TTJI24S-SFSR-FL-3-DUAL    Consult sales   Dual Element Type J, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, IEC Color Coded  
 M12CFM-TTKI24S-SFSR-FL-3-DUAL 4 Weeks   1,665.00    Dual Element Type K, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, IEC Color Coded  
 PVC Insulated and Jacketed Cables
 M12CFM-PPJ24S-SFSR-FL-3 4 Weeks   1,310.00    Type J, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, ANSI Color Coded  
 M12CFM-PPK24S-SFSR-FL-3 4 Weeks   1,285.00    Type K, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, ANSI Color Coded  
 M12CFM-PPJI24S-SFSR-FL-3 4 Weeks   1,285.00    Type JI, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, IEC Color Coded  
 M12CFM-PPKI24S-SFSR-FL-3 4 Weeks   1,285.00    Type KI, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, IEC Color Coded  
 M12CFM-PPJ24S-SFSR-FL-3-DUAL 4 Weeks   1,490.00    Dual Element Type J, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, ANSI Color Coded  
 M12CFM-PPK24S-SFSR-FL-3-DUAL 4 Weeks   1,515.00    Dual Element Type K, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, ANSI Color Coded  
 M12CFM-PPJI24S-SFSR-FL-3-DUAL    Consult sales   Dual Element Type J, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, IEC Color Coded  
 M12CFM-PPKI24S-SFSR-FL-3-DUAL    Consult sales   Dual Element Type K, M12 Straight Socket Style Connector One End, Stripped Leads the Other, 3 Meters Long, IEC Color Coded  
All dollar amounts on this site are shown in US currency.

 Note:
  • #20 and #24 AWG stranded conductors same price (note: PVC insulated cables are only available in #24AWG, PFA insuated cables are available in both #20 and #24AWG) .

  • For longer cables, change last number in model number to the desired length in meters and add the following to the price: for "TT" cable add $2 per meter, for "PP" cable add $1.25 per meter.

  • For steel braid on the "PP" or "TT" cable, add '"SB" to the end of the cable callout and add $2.50 per meter to the price. For BX hose, add "BX" to the end of the cable callout and add $2.50 per meter to the price.

  • To add a connector to the "FL" end of the cable, replace "FL" with the following and add the price shown:

  • For a miniature connector, add "SMPW" at no additional cost.

  • For a full size connector, add "OSTW" at no additional cost.

  • For the following M12 connectors add $10 each: straight plug "SMSR", right angled plug "RMSR", straight socket "SFSR", right angled socket "RFSR".


  •  Part Number Builder
    (1) (2) (3) (4) (5) (6) (7)   
    M
    M
    1
    1
    2
    2
    C
    C
    F
    F
    M
    M
    -
    -
    -
    -
    -
    -
    -
    -
    Qty:

    Option Descriptions
    (1) Cable Insulation
      Select
    TT for PFA Insulated and Jacketed
    PP for PVC Insulated and Jacketed
    (2) Thermocouple Type
      Select
    K for Type K with ANSI Color Code
    J for Type J with ANSI Color Code
    KI for Type K with IEC Color Code
    JI for Type J with IEC color code
    (3) Conductor Size
      Select
    20S for #20AWG Stranded (PFA Insulated Only)
    24S for #24AWG Stranded
    (4) Sensor Side Connector
      Select
    SFSR for Straight Socket Style M12
    RFSR for Right Angled Socket Style M12
    SMSR for Straight Plug Style M12
    RMSR for Right Angled Plug Style M12
    (5) Process End Termination
      Select
    FL for Stripped Leads
    SMSR for Straight Plug Style M12
    RMSR for Right Angled Plug Style M12
    SFSR for Straight Socket Style M12
    RFSR for Right Angled Socket Style M12
    SMPW-CC for Miniature Thermocouple Connector
    OSTW-CC for Full Size Thermocouple Connector
    (6) Cable Length
      Select
    3 for 3 meters Long
    5 for 5 meters Long
    10 for 10 meters Long
    15 for 15 meters Long
    20 for 20 meters Long
    (7) Number of TCs
      Select
    for Single
    -DUAL for Dual Cable
     NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


     Related Links - Related Products
     Related Products
    M12CM SERIES M12CM SERIES:
    M12 Cables with Over Molded and Compensated Connectors for Thermocouples
    M12 Series Probes M12 Series Probes:
    Thermocouple Probes With and Without Mounting Threads and M12 Connectors
    M12M Series M12M Series:
    Thermocouple Probes with Molded M12 Connectors
    OSTW-CC Series OSTW-CC Series:
    Thermocouple Connector Standard Size Round 2 Pin includes Integral Cable Clamp Cap
    SMPW-CC Series SMPW-CC Series:
    Miniature Size Thermocouple Connectors
    DRTB Series Thermocouple Terminal Blocks DRTB Series Thermocouple Terminal Blocks:
    Thermocouple Terminal Blocks with Audit Capable Female Connector
    M8/M12 Series M8/M12 Series:
    Field Mountable M8 and M12 Connectors
    M8C and M12C Series M8C and M12C Series:
    Molded M8 and M12 Thermocouple Extension Cable
       

       Back to topBack to top