USD$13,035.00
OM-CP-ETR101A-KIT
|
|
Complete System - Includes Data Logger, Waterproof NEMA 4 (IP65) Enclosure, Type K Thermocouple Probe, USB Interface Cable and Windows Software
|
|
10 Year Battery Life
|
|
1 Second Reading Rate
|
|
Multiple Start/Stop Function
|
|
Ultra High Speed Download
|
|
500,000 Reading Storage
|
|
Memory Wrap
|
|
Battery Life Indicator
|
|
Optional Password Protection
|
|
Programmable High and Low Alarms
|
|
Field Upgradeable
|
|
Ready to Use Right Out-of-the-Box
|
|
Free NIST Certification
|
View related products - Recorders
|
| |
|
|
|
The OM-CP-ETR101A-KIT comes assembled and includes a data
logger, temperature sensor (thermocouple Type K), waterproof
NEMA 4 (IP65) enclosure suitable for outdoor use, USB interface
cable, and software. Setup is fast and easy.
The OM-CP-ETR101A-KIT is suitable for a wide range of outdoor
applications including profiling the exhaust gas temperature of tractor
trailers, buses and trucks. Simply mount the enclosure containing the data
logger to the vehicle and insert the included type K thermocouple probe
into the vehicle exhaust pipe using a compression fitting. The data logger
can then record a complete exhaust gas temperature profile that can be
used in the selection of the correct diesel particulate filter (DPF) for the
vehicle.
Using the included software, the logger is programmed to record for
a set period. Data is stored in the data logger, and is downloadable
at any time via a pc or laptop computer.
The storage medium is non-volatile
solid state memory, providing
maximum data security even if the
battery becomes discharged. Its
small size allows it to fit almost
anywhere.
Data retrieval is simple. Plug it into
an available USB port and the easy
to use Windows® software does the
rest. The software converts your PC
into a real time strip chart recorder.
Data can be printed in tabular
format and can also be exported to
a text or Microsoft Excel® file.
Specifications
INTERNAL CHANNEL
Temperature Range: -40 to 80°C (-40 to 176°F)
Temperature Resolution: 0.1°C (0.18°F)
Calibrated Accuracy: ±0.25°C (±0.45°F)
REMOTE CHANNEL
Thermocouple Types: K**
Temperature Range: -270 to 1070°C (-454 to 1958°F)
Accuracy: ±2.0°C (24 AWG wire)
Resolution: 0.1°C
Thermocouple Connection: Female subminiature (SMP) connector
Cold Junction Compensation: Automatic based on internal channel
Max Thermocouple Resistance: 100 Ω
Reading Rate: 1 reading every second to 1 every 24 hours
Memory: 500,000 readings (software configurable memory
wrap); 250,000 readings in multiple start/stop mode or trigger setting mode
Wrap Around: Yes
Start Modes:
• Immediate start
• Delay start up to 18 months
• Multiple pushbutton start/stop
Multiple Start/Stop Mode: Start and stop the device multiple times
without having to download data or communicate with a PC
Multiple Start/Stop Mode Activation:
To Start the Device:
Press and hold the pushbutton for 5 seconds, the green LED
will flash during this time.
The device has started logging.
To Stop the Device:
Press and hold the pushbutton for 5 seconds, the red LED will
flash during this time.
The device has stopped logging.
Real Time Recording:
The device may be used with PC to monitor and record data in real-time
Alarm: Programmable high and low limits; alarm is activated when temperature reaches or exceeds set limits
Alarm Delay: A cumulative alarm delay may be set in which the
device will activate that alarm
(via LED) only when the device
has recorded a user specified time duration of data
Trigger Settings: High and low limits may be set for the
thermocouple channel. Once data meets or exceeds sets limits, the
device will record to memory. Bi-level start and stop triggers can
also be programmed. Users can specify the number or readings to
take after the device triggers.
LED Functionality:
Green LED Blinks: 10 second rate to indicate logging 15 second
rate to indicate delay start mode
Red LED Blinks: 10 second rate to indicate low battery and/or full
memory 1 second rate to indicate an alarm condition
Password Protection: An optional password may be programmed into
the device to restrict access to configuration options. Data may be
read out without the password.
Battery Type: 3.6V lithium battery (included); user replaceable
Battery Life: 10 years typical at a 15 minute reading rate
Data Format: Date and time stamped °C, °F, K, °R; µV, mV, V
Time Accuracy: ±1 minute/month (at 20ºC, stand alone data logging)
Computer Interface: USB (interface cable required); 115,200 baud
Software: XP SP3/Vista/7 and 8 (32 and 64-bit)
Operating Environment: -20 to 80ºC (-4 to 176°F),
0 to 95% RH non-condensing
Dimensions:
Data Logger: 36 H x 56 W x 16 mm D (1.4 x 2.2 x 0.6")
Waterbox: 87 H x 73 W x 27 mm D (3.5 x 2.9 x 1.1")
Thermocouple Wire: 24 gauge, 762 mm (30")
Thermocouple Probe: 153 L x 3.2 mm dia. (6 x 1?8")
Weight:
Complete Kit: 425 g (15 oz)
Waterproof Enclosure, Data Logger and Thermocouple: 283 g (10 oz)
**Use of stanless steel braided thermocouple
may allow water to wick in through the cable
and cause damage to the data logger
|
| |
|
|
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with 3.6 V lithium battery, OM-CP-IFC200 Windows software, 1.8 m (6') USB interface cable, thermocouple probe, waterproof enclosure and operator’s manual.
This product page contains items that either have a Lithium Battery installed in the equipment or have a Lithium Battery packed with the equipment. These items as being regulated for air transportation. The following applies:
• No FX1D, FX2D or FX3D can be used as a ship method.
• Only UPS1, UPS2 or UPS3 is authorized.
• For International shipments UPS and DHL can be used. For DHL internationally – Omega only has permission to ship Lithium Batteries no other Hazardous Material.
|
|
|
|
|
| |
|
|