4 Channels of Universal Analog Input
|
|
24-Bit Resolution
|
|
Measures: Voltage (±125 mV, ±1V, ±4V, ±15V, ±60V), Current (±25 mA), Thermocouples (J, K, T, E, R, S, N, B), RTDs (Pt100, Pt1000, 3- and 4-Wire), Resistance (2- and 4-Wire), and Bridge-Based Sensors (Quarter-, Half-, and Full-Bridge)
|
|
Simultaneous Sampling at Up to 100 S/s Per Channel
|
|
250 Vrms Channel-to-Channel and Channel-to-Ground Isolation
|
|
Built-In Thermistor for Cold-Junction Compensation (CJC)
|
|
Six-Position Input Screw Terminal Allows Different Measurement Types to be Performed On Each Channel
|
View related products - USB, RS232, RS485 and Ethernet Data Acquisition Systems
|
| |
|
|
|
This product has been discontinued.
The new OM-USB-2404-UI provides four channels
of 24-bit universal analog input with integrated signal
conditioning. The device can be used to measure a
variety of sensor types such as RTDs, thermocouples,
load cells, and other powered sensors. The four
channels are individually configurable, so a different
measurement type can be performed on each channel.
All channels are measured simultaneously at up to
100 S/s per channel.
The OM-USB-2404-UI can perform
the following measurements:
• Voltage
• Current
• Thermocouple
• RTD (3- and 4-wire)
• Resistance (2- and 4-wire)
• Bridge-based sensors (quarter-, half-, and full-bridge)
Measurement ranges vary for each type of
measurement (see PDF for complete specifications).
The device features a built-in current and voltage
excitation. The excitation circuit is protected from
overcurrent and overvoltage fault conditions. Each
channel also has a built-in thermistor for cold-junction
compensation (CJC) calculations when measuring
thermocouples. An analog pre-filter removes noise
that may be present in the signals prior to conversion.
With 250 Vac channel-to-channel and channel-to-ground
isolation, the OM-USB-2404-UI protects the
individual channels and connected computer and
ensures a reliable data stream. Each channel has a
detachable six-position screw terminal block for field
wiring connections.
The OM-USB-2404-UI ships with a 2 m (6') USB
cable and is powered by the 5V USB supply from
your computer. No external power is required.
The OM-USB-2404-UI is a USB 2.0 high-speed device
that is supported under popular Microsoft Windows®
operating systems. The OM-USB-2404-UI is fully
compatible with both USB 1.1 and USB 2.0 ports.
Software
The OM-USB-2404-UI module ships with an
impressive array of software, including the new
TracerDAQ®, a full-featured, out-of-the-box data
logging, viewing, and analysis application. Driver
support and detailed example programs are included
for Universal Library programming libraries for
Microsoft® Visual Studio® programming languages, and
other languages, including DASYLab®, and ULx for NI
LabVIEW® (comprehensive library of Vls and example
programs compatible with 32-bit and 64-bit LabVIEW
v8.5 through 2013) and InstaCal™ installation,
calibration and test utility-powerful solutions for
programmers and nonprogrammers alike. These
modules operate under Microsoft Windows® XP
(32-bit only) and VISTA/7/8 (32-bit and 64-bit)
operating systems.
The OM-USB-2404-UI data acquisition module is
supplied with TracerDAQ software which is a collection
of four virtual instrument applications used to
graphically display and store input data and generate
output signals:
• Strip Chart—Log and graph values acquired from analog inputs, digital inputs, temperature inputs and counter inputs
• Oscilloscope—Display values acquired from analog inputs
• Function Generator—Generate waveforms for analog outputs
• Rate Generator—Generate waveforms for counter outputs
TracerDAQ PRO is an enhanced version of TracerDAQ.
A comparison of some of the features included in
TracerDAQ vs TracerDAQ PRO is shown on the PDF.
SPECIFICATIONS
ANALOG INPUT
Number of Channels: 4
A/D Converter Resolution: 24-bit
A/D Converter Type: Delta-Sigma with analog pre-filtering
Sampling Mode: Simultaneous
TEDS Sensor Type Supported: IEEE 1451.4 TEDS Class II (interface)
Input Mode: Voltage, current, resistance (2- and 4-wire), RTD (3- and 4-wire), thermocouple, quarter-bridge, half-bridge, full-bridge
Conversion Time (No channels in TC mode)
High Speed: 10 ms for all channels
Best 60 Hz Rejection: 110 ms for all channels
Best 50 Hz Rejection: 130 ms for all channels
High Resolution: 500 ms for all channels
Conversion Time (One or More Channels in TC Mode)
High Speed: 20 ms for all channels
Best 60 Hz Rejection: 120 ms for all channels
Best 50 Hz Rejection: 140 ms for all channels
High Resolution: 510 ms for all channels
Overvoltage Protection
Terminals 1 and 2: ±30V
Terminals 3 Through 6, Across any Combination: ±60V
Input Impedance
Voltage Mode (±60V, ±15V, ±4V): 1 MΩ
Current Mode: <40 Ω
All Other Modes: >1GΩ
Input Bias Current: <1nA
Integral Non-Linearity (INL): ±15 ppm
Common Mode Rejection Ratio (CMRR): >100 dB
Normal Mode Rejection Ratio (NMRR)
Best 60 Hz Rejection: 90 dB at 60 Hz
Best 50 Hz Rejection: 80 dB at 50 Hz
High Resolution: 65 dB at 50 Hz and 60 Hz
GENERAL
Operating Temperature Range: 0 to 60ºC
(32 to 140ºF), 10 to 90% RH non-condensing
Storage Temperature Range: -40 to 85ºC
(-40 to 185ºF), 5 to 95% RH non-condensing
Communications: USB 2.0 Hi-Speed mode (480 Mbps)
is recommended; otherwise USB 1.1 full-speed mode
(12 Mbps)
Current Consumption from USB: 500 mA, maximum
Channel-to-Earth Ground Isolation
Continuous: 250 Vrms (measurement category
II for measurements performed on circuits directly
connected to the electrical distribution system)
Withstand: 2300 Vrms (verified by a 5 second
dielectric withstand test)
Channel-to-Channel Isolation
Continuous: 250 Vrms (measurement category
II for measurements performed on circuits directly
connected to the electrical distribution system)
Withstand: 1390 Vrms (verified by a 5 second
dielectric withstand test)
Signal I/O Connector: 6-position screw terminals
Screw terminal Wiring: 18 to 28 AWG copper conductor
wire with 7 mm (0.28") of insulation stripped from the end
Maximum Altitude: 2000 m (6562')
Dimensions: 134 L x 143 W x 39 mm H (5.27 x 5.64 x 1.54")
Weight: 567 g (1.25 lb)
|
| |
|
|
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with 2 m (6') USB cable and TracerDAQ software and user manual on CD.
|
|
|
|
|
| |
Related Links -
Related Products
|
Related Products |
|
OM-USB-2404: |
Discontinued - 4-Channel Analog Voltage Input USB Data Acquisition Modules |
|
|
|
OM-USB-3100_Series: |
4, 8, or 16-Channel Analog Voltage Output USB Data Acquisition Modules |
|
|
|
|
|
|
OMB-DAQ-2408 Series: |
24-Bit Multifunction USB Data Acquisition Modules for Temperature and Voltage Measurement |
|
|
|
OMB-DAQ-2416: |
High Performance Multi-Function I/O USB Data Acquisition Modules |
|
|
|
|
|
|