PT100 RTD Probes with M12 Molded Connectors
|
Click for larger image. |
|
|
USD$1,940.00
PR-22-3-100-A-1/8-0600-M12
|
|
316 Stainless Steel Probe with Nylon Overmolded M12 A-Coded 4-Pin Connector (IP67). An M12 Extension Cable is Required for Installation.
|
|
Fractional and Metric Probe Diameters and Lengths
|
|
Great for Use As-Is or With Compression Fittings, Spring Loaded Fittings and Thermowells
|
|
In-Line, Remote and Wireless Transmitters Available
|
View related products - RTD (PT100) Probes, Elements and Assemblies
|
| |
|
|
|
Note: These Sensors Require an M12 Extension Cable to Connect the Sensor To Your
Instrumentation. A Partial List Of Our M12 Extension Cables is Included in the Ordering Table Below.
The PR-22 style M12 RTD sensor is similar to our PR-21A sensor
except that it has an overmolded M12 connector (vs. a machined housing). This allows the PR-22 sensor to be a
lower cost alternative to the PR-21 if an integral mounting thread is not required.
Product Specifications Include:
Nylon Overmolded 4-Pin M12 "A-Coded" Plug Style Connector.
316 Stainless Steel Probe.
1/4" and 1/8" Diameter Probes in 6", 9", 12" 18" and 24" Lengths.
6mm and 3mm Diameter Probes in 150, 250, 350, 500, 750 and 1000mm Lengths.
4-Wire Pt100 or Pt1000 (100 ohms at 0°C or 1000 ohms at 0°C, .00385 TCR (alpha)) Platinum RTD.
Accuracy: Class A or Class B per IEC 60751.
Temperature Ranges are: -30 to 350°C (-22 to 622°F) Class A Accuracy, -50 to 500°C (-58 to
932°F) Class B Accuracy and -50 to 90°C (-58 to 194°F) Connector End.
Insulation Resistance: 100 Megohms Minimum at 100VDC at Room Ambient Temperature.
The PR-22 Molded M12 RTD sensor can be used in a wide variety of applications as-is, or with one or more of
Omega's In-Stock complimentary products such as:
Extension Cables with silicone, polyurethane or PVC cables and straight or right angled connectors.
In-line transmitters like the Omega SPRTX-SS and TX94A-SS series transmitters with integral M12 connectors.
Hand-held meters and instruments.
Contollers and panel meters.
Data loggers, data aquisition systems and recorders.
Stainless steel or brass compression fittings.
Or use them as replacement sensors in thermowells using Omega's spring loading kit.
The PR-22 RTD sensor contains an RTD element that meets the
resistance vs. temperature requirements of IEC 60751, making it compatible
with most of the proccess control and measurement equipment on the market today. The integral M12 connector,
wired in a 4-wire configuration, provides customers the flexability to use it in any 2-wire, 3-wire or 4-wire application
depending on your equipment or measurement accuracy needs.
|
| |
|
|
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: For Class B element accuracy, change "-A" in model number to "-B" and subtract $4 from the price.
|
|
|
Part Number Builder |
|
Option Descriptions
|
(1)
|
Element Specification
|
|
Select 100-A for Pt100 Class A 1000-A for Pt1000 Class A 100-B for Pt100 Class B
(2)
|
Probe diameter
|
|
Select -1/8 for 1/8 inch diameter probe -1/4 for 1/4 inch diameter probe -M2 for 2 mm diameter probe -M3 for 3 mm diameter probe -M6 for 6 mm diameter probe
(3)
|
Probe length
|
|
Select -0600-M12 for 6 inch probe length (1/8" or 1/4" diameter) -0900-M12 for 9 inch probe length (1/8" or 1/4" diameter) -1200-M12 for 12 inch probe length (1/8" or 1/4" diameter) -1800-M12 for 18 inch probe length (1/8" or 1/4" diameter) -2400-M12 for 24 inch probe length (1/8" or 1/4" diameter) -100-M12 for 100 mm probe length (3mm or 6mm diameter) -150-M12 for 150 mm probe length (2mm 3mm or 6mm diameter) -250-M12 for 250 mm probe length (2mm 3mm or 6mm diameter) -350-M12 for 350 mm probe length (3mm or 6mm diameter) -500-M12 for 500 mm probe length (3mm or 6mm diameter) -750-M12 for 750 mm probe length (3mm or 6mm diameter) -1000-M12 for 1000 mm probe length (3mm or 6mm diameter)
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| |
|
|
|
| |
Related Links -
Related Products
|
Related Products |
|
M12TX-PT100: |
Inline RTD Temperature Transmitter for 100Ω PT RTDs |
|
|
|
PR-31: |
Bendable and Vibration Resistant RTD Probes with High Temperature Molded M12 Connector |
|
|
|
PR-26 Series: |
Vibration Resistant and Bendable RTD (Pt100) Probes with M12 Connector and Mounting Threads (Fractional Sizes) |
|
|
|
PR-25CU Series: |
Fast Response RTD Sensor With Copper Tip and Circular Connector, Vibration Tested |
|
|
|
|
M12CFM RTD Series: |
M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs) |
|
|
|
PR-26 Metric Series: |
Vibration Resistant and Bendable RTD (Pt100) Probes with M12 Connector and Mounting Threads (Metric Sizes) |
|
|
|
|
|
|
Meters Product Finder: |
Meters Product Finder - It's the easiest way to sort through our selection of meters to find the right product for your application |
|
|
|
Data Acquisition System Product Finder: |
Data Acquisition Product Finder - It's the easiest way to sort through our selection of data acquisition systems to find the right product for your application |
|
|
|
Handheld Meters Product Finder: |
New Handhelds Product Finder - It's the easiest way to sort through our selection of handhelds to find the right product for your application |
|
|
|
Data Loggers Product Finder: |
Datalogger Product Finder - It's the easiest way to sort through our selection of dataloggers to find the right product for your application |
|
|
|
RTDs Product Finder: |
It's the easiest way to sort through our selection of RTDs to find the right product for your application |
|
|
|
|
|
|
|