USD$3,640.00
PR-25CUA-3-100-A-1/4-0600-M12
|
|
Element Located Inside Copper Alloy Tip for Improved Thermal Response
|
|
316L Stainless Steel Sheath and Housing
|
|
Can be Used for Measuring Bearing Temperature, in Thermowells, and As-Is
|
|
Operating Temperature Sensor: -50 to 250ºC (-58 to 482ºF) Connector: -50 to 85°C (-58 to 185°F)
|
|
Vibration Tested to ASTM-E1137: 3Gs from 5 to 500 Hz
|
|
Response Time (Typical): 4 Seconds for 63.2%, 3.25 Seconds for 50%, 7.5 Seconds for 90% [Water at 0.91 m (3')/second]
|
|
PR-25CUA Non-Threaded Version can be Used With Our M12-Handle for Hand-Held Use
|
View related products - RTD (PT100) Probes, Elements and Assemblies
|
| |
|
|
|
Our PR-25CU Copper Tipped RTD Probe combines the ease of use and robustness of our PR-21 RTD and adds a copper tip for improved response time. When trying to measure the temperature of objects like bearings and motors where contact is limited, the copper tip provides improved sensitivity. In thermowells where the contact between the sensor and thermowell bore is limited, copper tipped sensors can provide improved response and accuracy over standard immersion probes.
The ¼” diameter PR-25CU RTD has a response time of approximately 3.25 seconds for 50% response, 4 seconds for 63.2% response and 7.5 seconds for 90% response in water flowing at 3 feet per second. The 63.2% response time is approximately 33% faster than our standard PR-21 M12 Style Immersion RTD, and less than ½ the response time of our High Temperature PR-26 M12 Immersion RTD.
For ease of mounting, the PR-25CU is available with the following mounting thread options:
1/2NPT
3/8NPT
1/4NPT
M8x1
M10x1
G1/2 BSPP
G1/4 BSPP
Non-Threaded Housing
The mounting thread options above allow the probes to be used in a wide variety of applications, including:
As stand-alone immersion sensors.
Installed directly into your product or process using an NPT threaded port.
The non-threaded design can be combined with our M12-Handle accessory to convert it for hand-held sensing applications.
Other applications using a variety of available compression fittings or other accessories.
The PR-25CU, like all of our M12 enabled probes, comes standard with a 4-wire, 4-pin, M12 A-Coded plug connector for easy assembly to extension cables. This allows it to be used in any 2, 3 or 4-wire measurement system for maximum flexibility.
When ordering your PR-25CU sensor, don't forget your extension cable. Omega offers a wide selection of extension cables including over molded PVC, Polyurethane and Silicone cables, as well as customized cables in a variety of materials with optional stainless steel braid or hose for improved mechanical protection, and a wide selection of instrument connections.
Connect your PR-25CU RTD sensor to one or more of Omega's wide variety of in-stock controllers, data loggers, transmitters, hand held thermometers, PLCs, or other measurement & control products to complete your measurement or control system. Omega offers a selection of programmable and fixed range transmitters that can be connected directly to the M12 connection of your PR-25CU sensor. There are also wireless transmitter options available.
Specifications:
Metal Parts: 316L Stainless Steel Sheath and Housing, Copper Plug at Tip.
Connector: 4-Pin "A"-Coded M12 Plug Connector
Standard Mounting Threads: 1/2NPT, 3/8NPT, 1/4NPT, M8x1, M10x1, G1/2 BSPP , G1/4 BSPP and Non-Threaded
Standard Probe Diameter: 1/4" and 6mm
Standard Probe Lengths: 6" and 150mm
Sensor: Pt100 (100 Ohms at 0°C, .00385 TCR (alpha)) per IEC 60751Accuracy: Class A per IEC 60751
Temperature Range: -50 to 250°C Except for the Connector Which is 85°C Max
Insulation Resistance: 100 Megohms Minimum at 100VDC at Room Ambient
|
| |
|
|
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: Standard; For lengths other than 6", change “-0600” in model number to required length and add $1 per inch greater than 6", (example: 18" = 1800). For 1000 Ω RTD elements change “-100” to “-1000” in model number. For Class B Element, change the “-A” to “-B”. For 3/16" probe diameters, change “-1/4” in model number to “-3/16”, no additional cost. Metric; For lengths other than 150 mm, change “-M150” in model number to required length and add $1 per inch per 25mm greater than 150 mm. For 4.5 mm diameters, change “-M6” in model number to “-M4.5”, no additional cost.
Ordering Example: (1) PR-25CUA-3-100-A-1/4-0600-M12 Straight sheath, Class A, 100 Ohm, 1/4, USD$3,640.00
|
|
|
Part Number Builder |
|
Option Descriptions
|
(1)
|
Mounting
|
|
Select A for Straight sheath B for Straight sheath with 1/2 NPT mounting C for Straight sheath with 3/8 NPT mounting D for Straight sheath with 1/4 NPT mounting E for Straight sheath with M8x1 mounting thread F for Straight sheath with M10x1 mounting thread G for Straight sheath with G1/2 mounting thread H for Straight sheath with G1/4 mounting thread
(2)
|
RTD
|
|
Select 100 for 100 OHM 1000 for 1000 OHM
(3)
|
Class Element
|
|
Select A for Class A Element B for Class B Element
(4)
|
Diameter
|
|
Select 1/4 for 1/4 in 3/16 for 3/16 in M6 for 6 mm M4.5 for 4.5 mm
(5)
|
Length
|
|
Select 0600 for 6 inch Length M150 for 150 mm Length
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | | |
|
|
|
| |
Related Links -
Related Products
|
Related Products |
|
M12CM-RTD: |
High Temperature M12 Extension Cables |
|
|
|
|
M12CFM RTD Series: |
M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs) |
|
|
|
PR-21 Series: |
Vibration Resistant Platinum RTD (PT100) Sensor with M12 Connector and Mounting Thread |
|
|
|
PR-26 Metric Series: |
Vibration Resistant and Bendable RTD (Pt100) Probes with M12 Connector and Mounting Threads (Metric Sizes) |
|
|
|
PR-26 Series: |
Vibration Resistant and Bendable RTD (Pt100) Probes with M12 Connector and Mounting Threads (Fractional Sizes) |
|
|
|
|
DPi1701 Series: |
Graphic Display Panel Meter and Data Logger for Temperature and Process Measurement - Discontinued |
|
|
|
DPI-AL: |
Temperature/Process Meters with Alarm Outputs |
|
|
|
|
|
|
|