USD$5,115.00
PR-26A-3-100-A-1/4-0600-M12-1
|
|
Operating Temperature Range: -50 to 500°C (-58 to 932°F) Sensing End, -50 to 250°C (-58 to 482°F) at Connector
|
|
All Welded 316L Stainless Steel Housing and Probe
|
|
Available With or Without Mounting Thread (1/4, 3/8 and 1/2 NPT Mounting Threads Available)
|
|
1/4" Diameter Standard, 2" Minimum Length
|
|
Pt100 Class A Platinum RTD Standard, Pt1000 Platinum RTD Also Available (per IEC60751)
|
|
4 Wire Design Works With Any 2, 3 or 4-Wire Measurement System
|
|
Integral 4-Pin M12 Connector for Easy Connection
|
|
Bendable Probes (After the First 2" of Probe Tip) Using a Minimum Suggested Bend Radius of 2x the Probe Diameter
|
|
Vibration Tested to MIL-STD-202G, Method 204D, Test Condition A, 10gs from 10 to 500Hz (6" Long or shorter)
|
View related products - RTD (PT100) Probes, Elements and Assemblies
|
| |
|
|
|
Note: These Sensors Require an M12 Extension Cable to Connect the Sensor To Your
Instrumentation. A Partial List Of Our M12 Extension Cables is Included in the Ordering Table Below.
Omega's RTD sensors with M12 connections are designed to provide for easy and efficient installation or removal of these sensors for periodic calibration, troubleshooting or replacement. Gone
are the days of having to pull extension cables from cable trays in order to calibrate or replace the sensor, now you simply disconnect the sensor from the extension cable saving cost and downtime.
The Omega PR-26 RTD is a flexible and robust temperature sensor made with 316L Stainless Steel housings and sheaths for strength and corrosion resistance. The probe stem is made from
mineral insulated cable which produces a sensor that can be used to 500°C, and can be bent (except for the first 2 inches of the tip) to fit your application.
These sensors include a 4-pin, M12 A-Coded plug connector for easy assembly to patch cables or extension cables. Unlike other M12 enabled
sensors that have a maximum rating of 85 or 90°C on their connections, the PR-26 RTD can really take the heat with a connector rating of 250°C. Combine this sensor with
one of our proprietary M12CM-T24SSPC high temperature extension cables and you have a probe/cable combination that is unmatched in the industry.
For use in thermowells, the PR-26SL Spring-Loaded version of this sensor is the preferred solution. The PR-26SL design includes a non-threaded PR-26A style probe with
a self-gripping spring and 1/2NPT threaded fitting to insure that the probe will contact the bottom of the thermowell bore without damaging the sensor. This insures that the sensor
length will always be a perfect fit for your thermowell. See the PR-26SL page for additional information.
The mounting thread options on the PR-26 Series sensors allow them to be used in a wide variety of applications, including:
Stand alone immersion sensors.
Installed directly into your product or process using an existing metric threaded port.
When combined with our M12-Handle, non-threaded "A" style PR-26 probes can be used in hand-held sensing applications.
Other applications using a variety of available compression fittings or other accessories.
These RTD sensors can be used in any 2, 3 or 4-wire application by selecting one of the two available wiring
arrangements (see the wiring diagrams below) and using only those wires needed for your measurement connection. This allows for
simplified, trouble free installation with any existing application. This also allows the PR-26 series sensor to be used
for a wide variety of replacement applications since it can be connected as-is with just about any measurement or
control equipment available when combined with a 4-pin female M12 connector extension or patch cable.
Standard Mounting Threads: 1/2NPT, 3/8NPT, 1/4NPT and Non-Threaded
Standard Probe Diameters: 1/4" and 1/8"
Standard Probe Length: 6" (2" length mimimum)
Sensor: Pt100 (100 Ohms at 0°C, .00385 TCR (alpha)) Standard, Pt1000 and Other Options AvailableAccuracy: Class A Standard (per IEC 60751), Others Available Upon Request
Temperature Range: -50 to 500°C Except for the Connector Which is 250°C Max
Insulation Resistance: 100 Megohms Minimum at 100VDC at Room Ambient
Response Time: Appoximately 8.5 Seconds (63.2% Response) When Immersed in Water Flowing at 3 feet/sec
Vibration Resistance: 10g's from 10 to 500Hz per MIL-STD-202G, Method 204D, Test Condition A (6" long or shorter)
|
| |
|
|
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: For lengths other than 6", change “0600” in model number to required length and add $1 per inch or 25mm to the price. greater than 6" (example: 9" = 0900, 41/2" = 0450).
Ordering Example: (1) PR-26A-3-100-A-1/4-0600-M12-1 Element Pt100, Class A, Length (inch)6.00, Mounting Thread None, USD$5,115.00
|
|
|
Part Number Builder |
|
Option Descriptions
|
(1)
|
Mounting Thread
|
|
Select A for None B for 1/2 NPT C for 3/8 NPT D for 1/4 NPT
(2)
|
Element
|
|
Select 100 for Pt100 1000 for Pt1000
(3)
|
Accuracy
|
|
Select A for Class A B for Class B
(4)
|
Sheath Diameter
|
|
Select 1/4 for 1/4" Diameter 1/8 for 1/8" Diameter
(5)
|
Length (Custom lengths available)
|
|
Select 0600 for 6 Inch 1200 for 12 Inch
(6)
|
Wiring Option
|
|
Select 1 for Wiring Option 1 2 for Wiring Option 2
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
| | | | |
|
|
|
| |
Related Links -
Related Products
|
Related Products |
|
PR-21 Series: |
Vibration Resistant Platinum RTD (PT100) Sensor with M12 Connector and Mounting Thread |
|
|
|
PR-31: |
Bendable and Vibration Resistant RTD Probes with High Temperature Molded M12 Connector |
|
|
|
|
M12CM-RTD: |
High Temperature M12 Extension Cables |
|
|
|
|
M12CFM RTD Series: |
M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs) |
|
|
|
|
M12TX-PT100: |
Inline RTD Temperature Transmitter for 100Ω PT RTDs |
|
|
|
|
DPi1701 Series: |
Graphic Display Panel Meter and Data Logger for Temperature and Process Measurement - Discontinued |
|
|
|
|
|
|