TEL: 01-800-099-0420 (In México) | 001-203-359-7577 (Outside México)
 Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
Home >> Pressure Strain and... >> Pressure Transducers >> Millivolt Output Pr... >> PX1005

 - Discontinued Thin Film Cryogenic Pressure Transducer

PX1005   
CE
 
Thin Film Cryogenic Pressure Transducer
PX1005: - Discontinued Thin Film Cryogenic Pressure Transducer
Click for larger image.
   
High Performance
High Reliability
0.1% Stability for 18 months
Operates from -196 to +149°C (-320 to +300°F)
Exceptional Calibration Stability

View related products - Pressure Transducers

Click to scroll below to order See Specs PDF Related Items View a printer friendly page

This item is discontinued.


OMEGA’s PX1005 Sputtered Thin Film Pressure Transducer was designed for cryogenic service; it can operate in temperatures from -196°C to +149°C (-320°F to +300°F.) Yet, even in these difficult temperatures, it provides outstanding accuracy, long-term calibration stability and reliability. Static accuracy is ±0.25%, and thermal zero and sensitivity shifts over the compensated range of -196°C to +27°C (-320°F to +80°F) are less than ±0.01%/°F. The all-welded stainless-steel pressure cavity and double-isolated case ensures reliability in the tough environments normal to cryogenic service. OMEGA’s thin film technology makes this premium performance possible. The strain gages are sputter-deposited, forming a molecular bond with the substrate. There is virtually no shift, drift, or creep to cause the transducer’s calibration to change. OMEGA’s PX1005 is available in many standard ranges from 15 psi to 1,000 psi. A calibration record is supplied with every unit.

SPECIFICATIONS Excitation: 10 Vdc
Full Range Output: 30 mV nominal, 26 mV minimum
Residual Unbalance: 0 mV ±5% FSO at zero pressure
Input Resistance: 400 Ω nominal
Output Resistance: 400 Ω nominal
Insulation Resistance: 100 MΩ or greater @ 45 Vdc
Shunt Calibration: Provisions for single-arm, external shunt calibration
Sensing Element: 4-active-arm bridge using sputter-deposited thin-film elements.
Accuracy: Combined linearity, hysteresis and repeatability: ±0.25% FSO, BSL [Note: Performance is determined at 25°C ±1°C (77°F ±2°F), open circuit, rated excitation, unless otherwise specified]
Operating Temp Range: -196 to 149°C (-320 to 300°F)
Compensated Temp Range: -196 to 27°C (-320 to 80°F)
Thermal Effects:
   Span: ±0.01% FSO/°F
   Zero: ±0.01% FSO/°F
Vibration Sensitivity: At 35 g peak from 10 Hz to 2000 Hz (1/2" D.A.), the output shall not exceed 0.04% FSO/g for 15 psi units decreasing logarithmically to 0.003% FSO/g for 1000 psi units
Natural Frequency: 35 kHz at 1000 psi decreasing logarithmically 5 kHz at 15 psi
Shock: 100 g, 11 ms half sine wave without calibration shift or damage
Humidity: Per MIL-STD-810, method 507.1
Proof Pressure: 200% of rated pressure will not cause changes in performance beyond the specified tolerances
Burst Pressure: 3 times rated pressure
Wetted Parts: 17-4 PH vacuum melt or 15-5 PH stainless steel
Pressure Fitting: 7/16-20 male per MS33656-4
Mounting Isolation: Case isolation ensures that the sensing element will not be affected by external stresses
Mating Connector: PCS06E-10-6S(SR) (sold separately)
Weight: 145 g (5 oz) maximum


To Order (Specify Model Number)    
expand list What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.
 Part Number   Availability   Price   Description    Qty.
    PX1005L1-015AV    Consult sales   0-15 PSIA cryogenic pressure transducer, with integral electrical connector  
    PX1005L1-025AV    Consult sales   0-25 PSIA cryogenic pressure transducer, with integral electrical connector  
    PX1005L1-050AV    Consult sales   0-50 PSIA cryogenic pressure transducer, with integral electrical connector  
Click to expand/minimize a list of what others bought with the PX1005L1-100AV  PX1005L1-100AV    Consult sales   0-100 PSIA cryogenic pressure transducer, with integral electrical connector  
Click to expand/minimize a list of what others bought with the PX1005L1-250AV  PX1005L1-250AV    Consult sales   0-250 PSIA cryogenic pressure transducer, with integral electrical connector  
Click to expand/minimize a list of what others bought with the PX1005L1-500AV  PX1005L1-500AV    Consult sales   0-500 PSIA cryogenic pressure transducer, with integral electrical connector  
    PX1005L1-1KAV    Consult sales   0-1,000 PSIA cryogenic pressure transducer, with integral electrical connector  
 Accessories
Click to expand/minimize a list of what others bought with the PCS06E10-6S  PCS06E10-6S 7 Weeks   9,480.00    Mating connector for PX1005 (sold separately)  
All dollar amounts on this site are shown in US currency.

 Note: Some discoloration of the pressure connection and surrounding area may occure due to the hot/cold calibration of this product.

 Ordering Example: (1) PCS06E10-6S mating connector (sold separately), USD$9,480.00
 Part Number Builder
(1) (2)   
P
P
X
X
1
1
0
0
0
0
5
5
L
L
1
1
-
-
Qty:

Option Descriptions
(1) Range (psi)
  Select
015 for 0-15
025 for 0-25
050 for 0-50
100 for 0-100
250 for 0-250
500 for 0-500
1K for 0-1000
(2) Units
  Select
AV for Absolute Model
SV for Sealed Gage Model
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


 Related Links - Related Products
 Related Products
DP25B Series DP25B Series:
1/8 DIN Process Meter & Controller
DP41 DP41:
1/8 DIN High Performance Temperature, Process and Strain Meter
   

   Back to topBack to top




MMV | 6 | 020