The new SVH-120 Series is a
versatile, ¼ or ½" full port, high
pressure, pilot operated, solenoid
valve. The SVH-130 Series is a
compact size, for where space is
limited. The compact SVH-120
Series is ideal for flow control of high
pressure air, water, compressed
natural gas (CNG), hydrogen,
nitrogen, and other gases or light
liquids compatible with the materials
of construction, and leverages this
high pressure flow to its own
advantage in operating effectively
and efficiently.
The SVH-120 style valve is perfect
for use in hydrogen dispensing
tanks, commonly used in the
refueling of fleet vehicles. It is also
a used in many compressed natural
gas applications. With available
pressures to 10,000 psig there are
a wide range of applications that
include water, nitrogen and many
other compatible liquids. This
solenoid valve must be mounted with
the solenoid upright and vertical.
Specifications
Materials Of Construction
Valve Body: 316 SS
Pistons: PAEK
O-Rings: Buna-N/FKM “-VT”/PTFE
Backing Rings: Buna-N/FKM “-VT”/PTFE
Piston Rings/Seal: PTFE/302 SS
Cartridge: 316 SS/430 SS
Pilot/Seal: 303 SS/PTFE
Spring: 302 SS
Plunger: 430 SS
Bonnet Retainer: 430 SS
Cartridge Gasket: Nylon
Fluid Temp Range: -37 to 121°C (-35 to 250°F), -26 to 204°C (-15 to 400°F) (-VT)
Shipping Weight: 1.8 Kg (4 lbs){SVH-121}, 3.2 Kg (7 lbs) {SVH-122}
Cv: 4.5
Port Connections: ¼ NPT (SVH-121), ½ NPT (SVH-122)
Electrical
Duty: Continuous
Connection: ½ NPT, 18" leads
Power: 10 watts, 22 watts (-XP)
A C Inrush: 1 amp @120 Vac, 2.5 amp @120V AC (-XP)
AC Holding: 0.1 amp @ 120 Vac, 0.2 amp @ 120 Vac -XP
Insulation: Class “F”, Class “H” -XP
Maximum Operating Pressure:
A C Voltage: 7,500 Psig, 10,000 psig -XP
DC Voltage: 3,600 PSIG, 7,200 psig -XP
Minimum Pressure: 100 psig
|
| |
|
|
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with operator’s manual.
For units for Hydrogen service (Helium leak test) add “-HY” to the model number, for an additonal charge.
For Normally Open valve configuration add “-NO” to the model number, for an additional charge. **Normally Open valve configuration is not available on DC models.
For Oxygen cleaned units add “-OX” to the model number, for an additional charge.
For units with straight thread J1926 with o-ring seal add “-ST” to the model number, for an additional charge.
For units with a flared tubing connection add “-TC” to the model number, for an additional charge.
For units with FKM o-rings add “-VT” to the model number, for an additional charge.
For units with a higher pressure coil add “-XP” to the model number, for an additional charge.
|
|
|
|
|
| |
|
Back to top
|
|
|