TEL: 01-800-099-0420 (In México) | 001-203-359-7577 (Outside México)
 Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
Home >> Temperature Products >> Temperature Transmit... >> Miniature Transmitte... >> TX92G Series

RTD Miniature Temperature Transmitters - Discontinued

TX92G Series   
1 year warranty CE
 
RTD PT100 Transmitters
TX92G Series:RTD Miniature Temperature Transmitters - Discontinued
Click for larger image.
   
Easy to Mount in Protection Head
Fine Zero and Span Adjustments
ABS Construction with Watertight Enclosure
4-20 mA Output
Non-Isolated
± 0.1% FS Accuracy

View related products - Temperature Transmitters

Click to scroll below to order See Specs PDF Manuals View a printer friendly page

TX92G Series are discontinued. As an upgrade substitute, please check out the new TXUN temperature transmitter for details.

The economical OMEGA™ TX92G transmitter provides an output current of 4-20 mA proportional to the mV signal of a two wire RTD sensor input. The TX92G is very compact and mounts directly with OMEGA’s NB1 cast iron protection heads.

Specifications
Range: -40 to 49°C (-40 to 120°F),
-18 to 93°C (0 to 200°F),
-18 to 149°C (0 to 300°F),
-18 to 260°C (0 to 500°F),
-18 to 399°C (0 to 750°F),
-18 to 538°C (0 to 1000°F)
Input Type: 3-wire Pt100½ (a=0.00385)BS1904 and DIN 43760
Zero/Span Adjustment Range: ±25%
Current Output Limits: 3.5 to 29.5 mA
Max Loop Resistance: (Vs - 8.2V)/0.02 A= ohms Accuracy (at 25°C): ±0.1% (<0,3°C,FS)
Ambient Power Supply: 9-42Vdc; 24 Vdc recommended
Load Capability: 600½ MAX, @ 24 Vdc
Operating Temperature Range: -40 to +85°C (-40 to 185°F)
Storage Temperature Range: -50 to +95°C (-58 to 203°F)
Dimensions: 44.5 D x 27 mm H (1.75 x 1.06") (height includes terminal strip)
Weight: Approx. 30 g (1.1 oz)


All dollar amounts on this site are shown in US currency.

 Note: *Insert range code from chart below. All units come with complete operator’s manual.
For complete information on NB1 Thermocouple Probes and PR-12 RTD Probes, see Sections A and C of the Temperature Handbook.

   