Please check out our newer model 2-wire transmitter TX13 Series with more advanced features at a lower price.
Models TX93, TX94 and TX95 transmitters can eliminate long runs of costly field wiring in a variety of applications. A stable 4 to 20 mA output signal is provided proportional to the transmitters specific input type and calibrated temperature range (see Range Code Table below). Adjustability of ±25% for zero and span is provided to facilitate some rangeability.
The transmitted signal eliminates noise pickup, voltage drops, multiple cold junction errors and requires only a twisted pair of copper wire for loop connections. TX93, TX94 and TX95 are ultra-low profile transmitters at an economical price.
|
| |
|
|
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: Each unit supplied with complete operator’s manual. (1) Thermocouple models output is proportional to the mV output of the thermocouple. Not linearized to the temperature. (2) Non-isolated unit for use with ungrounded probes only.
Ordering Example: (3) TX93-J4 Transmitters with 0 to 500°F range, $89., USD$6,380.00 ea.
|
|
|
Part Number Builder |
|
Option Descriptions
|
(1)
|
Input Type
|
|
Select TX93 for Thermocouple input TX94 for RTD input TX95 for Voltage input NB1TX93 for NB1 thermocouple probe 12 Inch L 1/4 Inch OD ungrounded junction 304 SS sheath with TX93 transmitter PRTX94 for PR-12 RTD probe 12 Inch L 1/4 Inch OD 304 SS sheath with TX94 transmitter
(2)
|
Sensor Type and Temperature Range
|
|
Select J2 for J Thermocouple -18 to 93°C (0 to 200°F) K2 for K Thermocouple -18 to 93°C (0 to 200°F) T2 for T Thermocouple -18 to 93°C (0 to 200°F) E2 for E Thermocouple -18 to 93°C (0 to 200°F) J3 for J Thermocouple -18 to 149°C (0 to 300°F) K3 for K Thermocouple -18 to 149°C (0 to 300°F) T3 for T Thermocouple -18 to 149°C (0 to 300°F) E3 for E Thermocouple -18 to 149°C (0 to 300°F) J4 for J Thermocouple -18 to 260°C (0 to 500°F) K4 for K Thermocouple -18 to 260°C (0 to 500°F) T4 for T Thermocouple -18 to 260°C (0 to 500°F) E4 for E Thermocouple -18 to 260°C (0 to 500°F) J5 for J Thermocouple -18 to 399°C (0 to 750°F) K5 for K Thermocouple -18 to 399°C (0 to 750°F) E5 for E Thermocouple -18 to 399°C (0 to 750°F) J6 for J Thermocouple -18 to 538°C (0 to 1000°F) K6 for K Thermocouple -18 to 538°C (0 to 1000°F) E6 for E Thermocouple -18 to 538°C (0 to 1000°F) 1 for RTD -40 to 49°C (-40 to 120°F) 2 for RTD -18 to 93°C (0 to 200°F) 3 for RTD -18 to 149°C (0 to 300°F) 4 for RTD -18 to 260°C (0 to 500°F) 5 for RTD -18 to 399°C (0 to 750°F) 6 for RTD -18 to 538°C (0 to 1000°F)
|
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.
|
|
|
|
|
| |
Related Links -
Manual, Related Products
|
Product Manual |
Download TX94 - RTD Two-Wire Temperature Transmitter |
Download TX93 - Thermocouple Two-Wire Temperature Transmitter |
Related Products |
|
|
|
|
|