TEL: 01-800-099-0420 (In México) | 001-203-359-7577 (Outside México)
 Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation
Home >> Automation Products >> Power Products >> Fuses >> UL489 Molded Case Circuit Breakers

Circuit Breakers for Branch Circuit Protection

UL489 Molded Case Circuit Breakers   
CE RoHS
Circuit Breakers for Branch Circuit Protection
UL489 Molded Case Circuit Breakers:Circuit Breakers for Branch Circuit Protection
Click for larger image.
   
USD$1,455.00  AU-1C15UL
DIN Rail Mounted
Disconnect and Switching Function
17.5 mm (0.69") Width per Pole
Thermal Magnetic and Current Limiting
Available in AC and DC
240V, 480Y/277 Vac, 50/60Hz
125 Vdc (1-Pole), 250 Vdc (2-Pole)
10kA Short Circuit Interrupting Capacity
HACR Type 40°C (104°F)
Line/Load Reversible

View related products - Power Products

Click to scroll below to order See Specs PDF Related Items View a printer friendly page

The UL 489 Series miniature molded case circuit breakers are DIN rail mountable and provide feeder and branch circuit protection per UL 489. Typical uses include convenience receptacles, motor controls, load circuits leaving equipment, and heating and air conditioning. UL 489 Series miniature circuit breakers are available in one-, two-, three- and four-pole configurations and up to 23 different current ratings from 0.3A to 63A and can safely be used in applications up to 480Y/277 Vac with a 10kA short circuit withstand rating.

AC Application C-Trip Curve
Low inrush motors, resistive loads, wiring protection, receptacles, lighting, and control circuit applications. Relatively short thermal trip delay and medium magnetic trip point.
AC Applications D-Trip Curve
High inrush motors, transformers, power supplies, heaters and reactive loads. Relatively long thermal trip delay and very high magnetic trip point.
DC Applications C and D-Trip Curves
Telecommunication equipment, computer equipment, uninterruptable power supplies.


Features Provided by the Different Types of Circuit Breakers
UL1077 Recognized Supplementry Protectors
    Overload Protection

UL508 Listed Manual Motor Controllers
    Overload Protection
    Switching Function
    Disconnect Function

UL489 Miniature Molded Case Circuit Breakers
    Overload Protection
    Switching Function
    Disconnect Function
    Short Circuit Protection

Specifications
Current/Voltage Rating:
    AC: 0.3-63A – 240 Vac
    AC: 0.3-32A 480Y/277 Vac
    DC: 0.3-63A 125 Vdc 1-pole - 250 Vdc 2-pole
Electrical Life: 6000 cycles on/off
Mechanical Life: 10,000 cycles on/off
Calibration Temperature: 40°C (104°F)
Operating Temperature: -25 to 55°C (-13 to 131°F)
Storage Temperature: -25 to 70°C (-13 to 158°F)
Wire Connection: Copper wire only, 60/75°C
Terminal Size Acceptability: Top 18-3 AWG, Bottom18-2 AWG
Tightening Torque Minimum/Maximum: 17.7/ 22lb-in. (2/2.2 Nm)
Terminal Protection Degree: IP20
Dimensions:
Height: 105.3mm (4.15")
Width: One Pole 17.5mm (0.69"), 2 Pole 35mm (1.38"), 3 Pole 52.5 mm (2.07")


To Order (Specify Model Number)    
 Part Number   Availability   Price   Description RoHS   Qty.
 UL 489 Miniature Molded Case Circuit Breakers,

Popular Models in Stock - Use Part Number Builder Below for Additional Models
 C-Trip MCCB
 AU-1C5UL 13 Weeks   1,480.00    1-pole C-trip circuit breaker, 5A RoHS compliant
 AU-1C10UL 13 Weeks   1,455.00    1-pole C-trip circuit breaker, 10A RoHS compliant
 AU-1C15UL In Stock   1,455.00    1-pole C-trip circuit breaker, 15A RoHS compliant
 AU-1C20UL In Stock   1,455.00    1-pole C-trip circuit breaker, 20A RoHS compliant
 AU-2C10UL In Stock   2,910.00    2-pole C-trip circuit breaker, 10A RoHS compliant
 AU-2C15UL 13 Weeks   2,910.00    2-pole C-trip circuit breaker, 15A RoHS compliant
 AU-2C20UL 13 Weeks   2,910.00    2-pole C-trip circuit breaker, 20A RoHS compliant
 AU-2C25UL 13 Weeks   2,910.00    2-pole C-trip circuit breaker, 25A RoHS compliant
 AU-2C30UL 13 Weeks   2,910.00    2-pole C-trip circuit breaker, 30A RoHS compliant
 AU-2C40UL 13 Weeks   3,120.00    2-pole C-trip circuit breaker, 40A RoHS compliant
 AU-2C50UL 13 Weeks   3,120.00    2-pole C-trip circuit breaker, 50A RoHS compliant
 AU-3C3UL 13 Weeks   3,990.00    3-pole C-trip circuit breaker, 3A RoHS compliant
 AU-3C10UL 13 Weeks   3,990.00    3-pole C-trip circuit breaker, 10A RoHS compliant
 D-Trip MCCB
 AU-1D1UL 13 Weeks   1,455.00    1-pole D-trip circuit breaker, 1A RoHS compliant
 AU-1D2UL 13 Weeks   1,455.00    1-pole D-trip circuit breaker, 2A RoHS compliant
 AU-1D3UL 13 Weeks   1,455.00    1-pole D-trip circuit breaker, 3A RoHS compliant
 AU-1D5UL 13 Weeks   1,455.00    1-pole D-trip circuit breaker, 5A RoHS compliant
 AU-1D8UL 13 Weeks   1,455.00    1-pole D-trip circuit breaker, 8A RoHS compliant
 AU-1D10UL 13 Weeks   1,455.00    1-pole D-trip circuit breaker, 10A RoHS compliant
 AU-1D15UL 13 Weeks   1,455.00    1-pole D-trip circuit breaker, 15A RoHS compliant
 AU-1D30UL 13 Weeks   1,455.00    1-pole D-trip circuit breaker, 30A RoHS compliant
 AU-1D50UL 13 Weeks   1,560.00    1-pole D-trip circuit breaker, 50A RoHS compliant
 AU-2D2UL 13 Weeks   2,910.00    2-pole D-trip circuit breaker, 2A RoHS compliant
 AU-2D3UL In Stock   2,910.00    2-pole D-trip circuit breaker, 3A RoHS compliant
 AU-2D5UL 13 Weeks   2,910.00    2-pole D-trip circuit breaker, 5A RoHS compliant
 AU-2D8UL 13 Weeks   2,910.00    2-pole D-trip circuit breaker, 8A RoHS compliant
 AU-2D10UL 13 Weeks   2,910.00    2-pole D-trip circuit breaker, 10A RoHS compliant
 AU-2D15UL 13 Weeks   2,910.00    2-pole D-trip circuit breaker, 15A RoHS compliant
 AU-2D20UL 13 Weeks   2,910.00    2-pole D-trip circuit breaker, 20A RoHS compliant
 AU-2D25UL 13 Weeks   2,910.00    2-pole D-trip circuit breaker, 25A RoHS compliant
 AU-2D30UL 13 Weeks   2,910.00    2-pole D-trip circuit breaker, 30A RoHS compliant
 AU-2D40UL 13 Weeks   3,120.00    2-pole D-trip circuit breaker, 40A RoHS compliant
 AU-2D50UL 13 Weeks   3,120.00    2-pole D-trip circuit breaker, 50A RoHS compliant
 AU-3D2UL 13 Weeks   3,990.00    3-pole D-trip circuit breaker, 2A RoHS compliant
 AU-3D5UL In Stock   3,990.00    3-pole D-trip circuit breaker, 5A RoHS compliant
 AU-3D8UL 13 Weeks   3,990.00    3-pole D-trip circuit breaker, 8A RoHS compliant
 AU-3D10UL 13 Weeks   3,990.00    3-pole D-trip circuit breaker, 10A RoHS compliant
 AU-3D15UL 13 Weeks   3,990.00    3-pole D-trip circuit breaker, 15A RoHS compliant
 AU-3D20UL 13 Weeks   3,990.00    3-pole D-trip circuit breaker, 20A RoHS compliant
 AU-3D30UL 13 Weeks   3,990.00    3-pole D-trip circuit breaker, 30A RoHS compliant
 AU-3D32UL 13 Weeks   4,300.00    3-pole D-trip circuit breaker, 32A RoHS compliant
 AU-3D50UL 13 Weeks   4,300.00    3-pole D-trip circuit breaker, 50A RoHS compliant
 Accessories - See SPEC above for all accessories
 AU-N32UL 13 Weeks   1,685.00    Neutral pole 0.3-32A RoHS compliant
 AU-N63UL 13 Weeks   1,685.00    Neutral pole 40-63A RoHS compliant
 AU-H10UL 13 Weeks   1,680.00    Auxiliary contact, 1NO RoHS compliant
 AU-H11UL 13 Weeks   1,785.00    Auxiliary contacts, 1NO &anp; 1NC RoHS compliant
 AU-FA24UL    Consult sales   Shunt trip, 24V ac/dc, 0.6A RoHS compliant
 AU-FA110UL    Consult sales   Shunt trip, 110-240V, 277V ac RoHS compliant
 AU-UA120UL    Consult sales   Undervoltage trip 120V ac, 60Hz RoHS compliant
All dollar amounts on this site are shown in US currency.

 Note: Note: (*)= ”C” for C-curve and “D” for d-curve.
 Ordering Example: (1) AU-1C5UL Single pole, 5 A C-trip curve circuit breaker, USD$1,480.00
 Part Number Builder
(1) (2) (3) (4)   
A
A
U
U
Qty:

Option Descriptions
(1) Poles
  Select
-1 for 1 pole
-2 for 2 pole
-3 for 3 pole
(2) Curve
  Select
C for C-curve
D for D-curve
(3) Rated Current
  Select
03 for 0.3A
05 for 0.5A
1 for 1.0A
1.6 for 1.6A
2 for 2.0A
3 for 3.0A
4 for 4.0A
5 for 5.0A
6 for 6.0A
8 for 8.0A
10 for 10A
12 for 12A
13 for 13A
15 for 15A
16 for 16A
20 for 20A
25 for 25A
30 for 30A
32 for 32A
40 for 40A
50 for 50A
60 for 60A
63 for 63A
(4) Current
  Select
UL for AC
DL for DC
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


 Related Links - Related Products
 Related Products
EK Series Polycarbonate Enclosures EK Series Polycarbonate Enclosures:
NEMA 4X Enclosures for DIN Rail Mount IEC Components - Circuit Breakers, Fuse Holders & Timers
R Series UL1077 Supplementary Protectors R Series UL1077 Supplementary Protectors:
DIN Rail Mount Circuit Breakers
DIN Rail Terminal Blocks, Feed Through and Ground Terminals DIN Rail Terminal Blocks, Feed Through and Ground Terminals:
AVK Series Feed Through DIN Rail Mounting Terminal Blocks, 600V, 20 to 175 Amp, 26 to 6-2/0 AWG
DRTB-Rail Series DRTB-Rail Series:
DIN Rails, Standard and Pre-Cut Lengths
ASK Fuse Holder Series ASK Fuse Holder Series:
DIN Rail Fuse Holders
SCE-ELJ Series Enviroline® Junction Electrical Enclosures SCE-ELJ Series Enviroline® Junction Electrical Enclosures:
NEMA Type 4 Junction Outdoor Electrical Enclosures, Sizes from 6x4 to 20x20.
   

   Back to topBack to top




MMV | 6 | 020