Metal-Oxide Semi-Conductor Sensor within Vented Ball Housing Detects Ammonia, Toluene, Ethanol, Hydrogen Sulfide (H2S) and Cigarette Smoke
Make Total VOC Concentration Measurements, Ambient Temperature, Relative Humidity (RH), Dew Point and Wet Bulb Temperatures
Logs Up to 32,000 Data Points
Powerful Data Logging Software
Adjustable High VOC Concentration Audible Alarm
Min/Max Memory (for All Measured Parameters) and Data Hold
Separate Automated Procedures for VOC Zero Adjustment and Background Calibration
Manually Off-Settable Temperature and RH Sensor Drift
Large Backlit Dual-Readout LCD
Tripod Mountable
Discontinued, no replacement
The HHAQ-107 VOC meter is ideal for making general
measurements of mixed gas volatile organic
compound (VOC) levels as part of an indoor air quality
(IAQ) maintenance program. Much less expensive
than photo-ionization meters designed to make precise
measurements of VOC levels from a single gas.
Small and light weight with a tripod mount fitting, the
HHAQ-107 is a versatile tool for HVAC and
IAQ technicians. The meters storage capacity can be
entirely devoted to VOC readings or split 3 ways for
VOC, ambient temperature and relative humidity. The
HHAQ-107 incudes powerful data logging software for
downloading readings to a PC and printing in table or
graph form.
SPECIFICATIONS VOC Measurement Range/Resolution: 0 to 50/0.01 ppm VOC Warmup Time: 10 minutes first use, 2 minutes thereafter VOC Sensor Type/Longevity: Metal-oxide semiconductor/5 years (typical) Temperature Measurement Range: -10 to 50°C (14 to 122°F) Temperature Measurement Accuracy/Resolution: ±0.6°C (1.2°F)/0.1° RH Measurement Range: 10 to 90% RH RH Measurement Accuracy/Resolution: ±5% of reading at 25°C (77°F); ±7% of reading elsewhere in range/0.1% RH Dew Point Measurement Range: -73 to 47°C (-99.2 to 118°F) Wet Bulb Measurement Range: -11 to 48.2°C (12.2 to 118.8°F) Data Logging Capacity: 32,004 points Display Type/Size: Dual readout LCD/51 mm (2") diagonal Auto Power-Off Trigger: 15 minutes of front-panel inactivity (can be disabled) Operating Temperature: 0 to 50°C (32 to 122°F) at 0 to 95% RH, non-condensing Dimensions: 210 L x 60 W x 25 mm D (8.3 x 2.4 x 1.0") Weight: 204 g (7.2 oz), including batteries Power Source: (6) “AAA” batteries (included) or included 110 Vac adaptor
† All dollar amounts on this site are shown in US currency.
Note: Comes complete with meter, PC-compatible data logging program
on mini-disc, USB cable, AC adaptor, soft pouch, (6) “AAA” batteries
and operator’s manual.